Terry Walton

Prof. Terry Walton

University of Sydney
orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 March 2021 in Journal of Prosthodontics
Verified
Journal Article
Closed access
PDF file
TWTerry Walton
Terry Walton
DLDanielle M Layton
Danielle M Layton

22 July 2021 in Coatings
Verified
Journal Article
Open access
PDF file
TWTerry Walton
Terry Walton
Objectives: This study aimed to measure non-destructively gold (Au) electrodeposited on a high-gold alloy by modulating coating time and comparing this to sputtering Au to known thicknesses. Methods: Au was electrodeposited (plated) on 11 high-gold alloy plates (A–K) at 2.8V between 20 and 220 min. Seven Au strips were sputter coated on the same alloy to known thicknesses (range 50–500 nm). Energy dispersive X-ray spectroscopy (EDS) was used to measure minimal electron energy (E0) required to penetrate Au coatings and generate x-ray signals of 1% atomic palladium (Pd) from the underlying alloy for test samples and Au strips. % Pd X-ray concentration at maximum 30 kV was also obtained. The obtained signal–thickness relationship of known Au strip thicknesses was used to calculate Au thickness on the A–K samples based on two analytical relations. Energy dispersive X-ray fluorescence spectroscopy (XRF) was used as a complementary method to ensure coating thickness estimations were accurate. Results: EDS values for all reference and unknown thicknesses were obtained and verified with XRF. Correlating these signals with the Data Analysis Software and matching with known plating times allowed estimation of Au thickness of the unknown samples (range 27–425 nm). Estimated thicknesses were shown to have a linear relationship with plating time except for samples C–D, where there was an inverted relationship. Significance: A non-destructive method for measuring electrodeposited thickness of Au on high-gold alloys related to plating time was developed and verified. There is a linear relationship to Au thickness and plating time between 20 and 220 min.

21 November 2023 in Coatings
Verified
Journal Article
Open access
PDF file
TWTerry Walton
Terry Walton
Purpose: The objective of the study was to qualitatively assess the micro-gap dimensions, connecting fitting surface profile, and bacterial leakage of cast high-gold-alloy UCLA abutments, with or without electrodeposited gold coatings attached to external hexagon implants. Materials and methods: Sixteen plastic UCLAs (PUCLAs) were cast with a high-gold-content alloy. Eight were electrolytically gold plated. Five machined cast-to-UCLA (GUCLA) control abutments were cast with the same alloy. All abutments were attached to external hexagon implants, giving 21 implant-abutment combinations (IACs). External perimeter micro-gaps measured with SEM under shadow eliminating silhouette illumination and 2000× magnification were averaged over three regions. The IACs were examined for E. coli leakage following an initial sterility test. Disassembled combinations were examined with SEM, and surface profiles were qualitatively assessed. Results: External micro-gap measurements did not reflect the variable connecting surface profiles, but average values < 5.0 μm were observed for all IACs measured under the shadow eliminating silhouette illumination for both cast and pre-machined external hexagon abutments with and without Au plating. E. coli transfer was observed in 3 of 5 PUCLA-plated and 2 of 5 PUCLA-non-plated IACs. No transfer occurred in the 3 GUCLA-non-plated or 2 GUCLA-plated control IACs. Abutment connecting surfaces, both Au-plated and not Au-plated, showed plastic deformation (smearing) in variable mosaic patterns across the micro-gap. Conclusions: Micro-gap dimensions < 5μm were obtained with both the high noble metal cast and pre-machined control external hexagon abutments with and without Au electrodeposited on the abutment connecting surface. Regions of intimate contact due to plastic deformation (smearing) of these surfaces were observed. A continuous smeared region around the circumference of the surfaces can provide an effective barrier to the egress of E. coli bacteria from the internal regions of the implant under static loading. The sample size was insufficient to determine if the gold coating resulted in a superior bacterial barrier.

31 October 2023 in Preprints.org
Verified
Preprint
Open access
PDF file
TWTerry Walton
Terry Walton
Purpose: The objective of the study was to qualitatively assess micro-gap dimensions, connecting fitting surface profile and bacterial leakage of machined and cast high gold alloy UCLA abutments, with or without electrodeposited gold coatings attached to external hexagon implants. Materials and methods: 16 plastic UCLA (PUCLA) and 5 machined cast-to UCLA (GUCLA) abutments were cast with a high gold content alloy. 10 were electrolytically gold plated (8 - PUCLA, 2 - GUCLA). All abutments were attached to implants giving 21 implant-abutment combinations (IACs). External perimeter micro-gaps measured with SEM under different illumination and magnification conditions were averaged over three regions. The IACs were examined for E.coli leakage following an initial sterility test. Disassembled combinations were examined with SEM and surface profiles qualitatively assessed. Results: External micro-gap measurements did not reflect the variable connecting surface profiles but average values < 3.5 μm were observed for all IACs. Bacterial transfer was observed in 3 of 5 PUCLA plated and 2 of 5 PUCLA non-plated IACs. No transfer occurred in the 3 GUCLA non-plated or 2 GUCLA plated IACs. Abutment connecting surfaces, both Au plated and not Au plated, showed plastic deformation (smearing) in variable mosaic patterns across the micro-gap. External micro-gap dimensions although not truly reflective of surface connecting profiles averaged < 3.5 μm measured under shadow eliminating silhouette illumination for both cast and pre-machined external hexagon abutments with and without Au plating. Conclusions: Micro-gap dimensions < 5 μm were obtained with both high noble metal cast and pre-machined external hexagon abutments with and without Au electrodeposited on the abutment connecting surface. Regions of intimate contact due to plastic deformation (smearing) of these surfaces was observed. A continuous smeared region around the circumference of the surfaces can provide an effective barrier to egress of E.coli bacteria from the internal regions of the implant under static loading.

1 January 2016
Verified
Book Chapter
Closed access
TWTerry Walton
Terry Walton

10 February 2026 in Preprints.org
Verified
Preprint
Open access
PDF file
ABAmylia Kesha Bal
Amylia Kesha Bal
TWTerry Walton
Terry Walton
HKHedi Verena Kruse
Hedi Verena Kruse
DHDale HOWES
Dale HOWES
The lack of integrity at the implant-abutment junction (IAJ) contributes to problems such as micromovements and microbial colonization. This study aimed to (1) design a protocol for assessing microleakage at the IAJ using chromophore analysis that hasn’t been involved in other analysis, (2) compare gas and dye leakage using titanium (Ti) and cobalt chrome (CoCr) abutments, and (3) assess the effect of gold (Au) gilding on sealing. Forty abutments were divided into five groups: milled Ti (MTi); cast CoCr (CCoCr); milled CoCr (MCoCr); cast CoCr with Au gilding (CCoCrG); and milled CoCr with Au gilding (MCoCrG). Samples were connected to a pressurised gas and dye reservoir. Chromophore analysis using crystal violet was performed via UV-Vis spec-trometer to calculate leakage concentration. Scanning electron microscopy (SEM) analysis assessed surface morphology which revealed an intimate contact with the MTi and MCoCr but irregularities at the CCoCr abutments. Results showed gas leakage in CCoCr and MCoCr groups, while no true dye leakage occurred in MTi, MCoCr and MCoCrG assemblies. CCoCr exhibited the poorest seal; however, Au gilding improved the seal in these samples. Chromophore analysis using crystal violet provided an ac-curate quantitative assessment. Milled abutments demonstrated significantly less mi-croleakage than cast (non-gilded) versions, Au gilding effectively reduced leakage.