Amylia Kesha Bal

Dr. Amylia Kesha Bal

orcid

Research Focus & Metrics

Academic Career Length

1Year (2026-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 February 2026 in Preprints.org
Verified
Preprint
Open access
PDF file
ABAmylia Kesha Bal
Amylia Kesha Bal
TWTerry Walton
Terry Walton
HKHedi Verena Kruse
Hedi Verena Kruse
DHDale HOWES
Dale HOWES
The lack of integrity at the implant-abutment junction (IAJ) contributes to problems such as micromovements and microbial colonization. This study aimed to (1) design a protocol for assessing microleakage at the IAJ using chromophore analysis that hasn’t been involved in other analysis, (2) compare gas and dye leakage using titanium (Ti) and cobalt chrome (CoCr) abutments, and (3) assess the effect of gold (Au) gilding on sealing. Forty abutments were divided into five groups: milled Ti (MTi); cast CoCr (CCoCr); milled CoCr (MCoCr); cast CoCr with Au gilding (CCoCrG); and milled CoCr with Au gilding (MCoCrG). Samples were connected to a pressurised gas and dye reservoir. Chromophore analysis using crystal violet was performed via UV-Vis spec-trometer to calculate leakage concentration. Scanning electron microscopy (SEM) analysis assessed surface morphology which revealed an intimate contact with the MTi and MCoCr but irregularities at the CCoCr abutments. Results showed gas leakage in CCoCr and MCoCr groups, while no true dye leakage occurred in MTi, MCoCr and MCoCrG assemblies. CCoCr exhibited the poorest seal; however, Au gilding improved the seal in these samples. Chromophore analysis using crystal violet provided an ac-curate quantitative assessment. Milled abutments demonstrated significantly less mi-croleakage than cast (non-gilded) versions, Au gilding effectively reduced leakage.

22 March 2026 in Coatings
Verified
Journal Article
Open access
PDF file
ABAmylia Kesha Bal
Amylia Kesha Bal
TWTerry Walton
Terry Walton
HKHedi Verena Kruse
Hedi Verena Kruse
DHDale HOWES
Dale HOWES
The lack of integrity at the implant–abutment junction (IAJ) contributes to problems such as micromovements and microbial colonisation. This study aimed to (1) design a protocol for assessing microleakage at the IAJ using chromophore analysis not previously reported for this specific application, (2) compare gas and dye leakage between titanium (Ti) and cobalt chrome (CoCr) abutments, and (3) assess the effect of gold (Au) gilding on sealing. Forty abutments were divided into five groups: milled Ti (MTi); cast CoCr (CCoCr); milled CoCr (MCoCr); cast CoCr with Au gilding (CCoCrG); and milled CoCr with Au gilding (MCoCrG). Samples were subjected to internal pressure within a gas and dye reservoir. Chromophore analysis via UV-Vis spectrometer was used to calculate crystal violet leakage concentrations. Scanning electron microscopy (SEM) revealed close adaptation in the MTi and MCoCr groups, contrasting with irregularities in the CCoCr groups. Correspondingly, gas leakage and dye leakage were most prevalent in the CCoCr group. Fisher exact test demonstrated a statistically significant difference (p = 0.026) between the MCoCr and CCoCr abutments. While CCoCr exhibited the highest failure rate (62.5%), Au gilding demonstrated a trend toward reduced leakage (25% failure rate), though this did not reach statistical significance (p = 0.315). This chromophore analysis represents a viable and objective assessment of IAJ integrity.