Hatim Seoudy

Dr. Hatim Seoudy


Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
Verified
Journal Article
Open access
PDF file
TPThomas Puehler
Thomas Puehler
CFChristine Friedrich
Christine Friedrich
GLGeorg Lutter
Georg Lutter
MKMaike Kornhuber
Maike Kornhuber
MSMohamed Salem
Mohamed Salem
AHAssad Haneya
Assad Haneya
The study was approved by the institutional review board (IRB) at the University Medical Center Campus Kiel, Kiel, Germany (reference number: AZ D 559/18) and registered at the German Clinical Trials Register (reference number: DRKS00022222). Objective. Unilateral pulmonary edema (UPE) is a complication after minimally invasive mitral valve surgery (MIMVS). We analyzed the impact of this complication on the short- and long-term outcome over a 10-year period. Methods. We retrospectively observed 393 MIMVS patients between 01/2009 and 12/2019. The primary endpoint was a radiographically and clinically defined UPE within the first postoperative 24 h, secondary endpoints were 30-day and long-term mortality and the percentage of patients requiring ECLS. Risk factors for UPE incidence were evaluated by logistic regression, and risk factors for mortality in the follow-up period were assessed by Cox regression. Results. Median EuroSCORE II reached 0.98% in the complete MIMVS group. Combined 30-day and in-hospital mortality after MIMVS was 2.0% with a 95, 93 and 77% survival rate after 1, 3 and 10 years. Seventy-two (18.3%) of 393 patients developed a UPE 24 h after surgery. Six patients (8.3%) with UPE required an extracorporeal life-support system. Logistic regression analysis identified a higher creatinine level, a worse LV function, pulmonary hypertension, intraoperative transfusion and a longer aortic clamp time as predictors for UPE. Combined in hospital mortality and 30-day mortality was slightly but not significantly higher in the UPE group (4.2 vs. 1.6%; p = 0.17). Predictors for mortality during follow-up were age ≥ 70 years, impaired RVF, COPD, drainage loss ≥ 800 mL and length of ventilation ≥ 48 h. During a median follow-up of 4.6 years, comparable survival between UPE and non-UPE patients was seen in our analysis after 5 years (89 vs. 88%; p = 0.98). Conclusions. In-hospital outcome with UPE after MIMVS was not significantly worse compared to non-UPE patients, and no differences were observed in the long-term follow-up. However, prolonged aortic clamp time, worse renal and left ventricular function, pulmonary hypertension and transfusion are associated with UPE.

Verified
Journal Article
Open access
PDF file
XZXiling Zhang
Xiling Zhang
TPThomas Puehler
Thomas Puehler
LSLars Sondergaard
Lars Sondergaard
DFDerk Frank
Derk Frank
HSHatim Seoudy
Hatim Seoudy
GLGeorg Lutter
Georg Lutter
Over the last two decades, transcatheter devices have been developed to repair or replace diseased mitral valves (MV). Transcatheter mitral valve repair (TMVr) devices have been proven to be efficient and safe, but many anatomical structures are not compatible with these technologies. The most significant advantage of transcatheter mitral valve replacement (TMVR) over transcatheter repair is the greater and more reliable reduction in mitral regurgitation. However, there are also potential disadvantages. This review introduces the newest TMVr and TMVR devices and presents clinical trial data to identify current challenges and directions for future research.

24 October 2020 in Clinical Research in Cardiology
Verified
Journal Article
Open access
PDF file
HSHatim Seoudy
Hatim Seoudy
MLMoritz Lambers
Moritz Lambers
VWVincent Winkler
Vincent Winkler
LDLinnea Dudlik
Linnea Dudlik
SFSandra Freitag-Wolf
Sandra Freitag-Wolf
DFDerk Frank
Derk Frank
Background: Elevated pre-procedural high-sensitivity troponin T (hs-TnT) levels predict adverse outcomes in patients with severe aortic stenosis (AS) undergoing transcatheter aortic valve replacement (TAVR). It is unknown whether elevated troponin levels still provide prognostic information during follow-up after successful TAVR. We evaluated the long-term implications of elevated hs-TnT levels found at 1-year post-TAVR. Methods and results: The study included 349 patients who underwent TAVR for severe AS from 2010–2019 and for whom 1-year hs-TnT levels were available. Any required percutaneous coronary interventions were performed > 1 week before TAVR. The primary endpoint was survival time starting at 1-year post-TAVR. Optimal hs-TnT cutoff for stratifying risk, identified by ROC analysis, was 39.4 pg/mL. 292 patients had hs-TnT < 39.4 pg/mL (median 18.3 pg/mL) and 57 had hs-TnT ≥ 39.4 pg/mL (median 51.2 pg/mL). The high hs-TnT group had a higher median N-terminal pro-B-type natriuretic peptide (NT-proBNP) level, greater left ventricular (LV) mass, higher prevalence of severe diastolic dysfunction, LV ejection fraction < 35%, severe renal dysfunction, and more men compared with the low hs-TnT group. All-cause mortality during follow-up after TAVR was significantly higher among patients who had hs-TnT ≥ 39.4 pg/mL compared with those who did not (mortality rate at 2 years post-TAVR: 12.3% vs. 4.1%, p = 0.010). Multivariate analysis identified 1-year hs-TnT ≥ 39.4 pg/mL (hazard ratio 2.93, 95% CI 1.91–4.49, p < 0.001), NT-proBNP level > 300 pg/mL, male sex, an eGFR < 60 mL/min/1.73 m2 and chronic obstructive pulmonary disease as independent risk factors for long-term mortality after TAVR. Conclusions: Elevated hs-TnT concentrations at 1-year after TAVR were associated with a higher long-term mortality. Graphic

Verified
Journal Article
Open access
PDF file
TPThomas Puehler
Thomas Puehler
NPNina Sophie Pommert
Nina Sophie Pommert
SFSandra Freitag-Wolf
Sandra Freitag-Wolf
HSHatim Seoudy
Hatim Seoudy
MEMarkus Ernst
Markus Ernst
GLGeorg Lutter
Georg Lutter
Background. The significance of concomitant tricuspid regurgitation (TR) in the context of transcatheter aortic valve replacement (TAVR) remains unclear. This study aimed to analyze the severity of TR before and after TAVR with regard to short- and long-term survival and to analyze the influencing factors. Methods. In our retrospective analysis, TR before and after TAVR was examined and patients were classified into groups accordingly. Special attention was paid to patients with post-interventional changes in TR. Mortality after TAVR was considered the primary endpoint of the analysis and major complications according to the Valve Academic Research Consortium 3 (VARC3) were compared. Moreover, biomarkers and risk factors for worsening or improvement of TR through TAVR were analyzed. Results. Among 775 patients who underwent TAVR in our center between January 2009 and December 2019, 686 patients (89%) featured low- and 89 patients (11%) high-grade TR. High-grade pre-TAVR TR was associated with worse short- (30-day), mid- (2-year) and long-term survival up to 8 years. Even though in nearly half of the patients with high-grade TR the regurgitation improved within seven days after TAVR (n = 42/89), this did not result in a survival benefit for this subgroup. On the other hand, a worsening of low-grade TR was seen in more than 10% of the patients (n = 73/686), which was also associated with a worse prognosis. Predictors of worsening of TR after TAVR were adipositas, impaired right ventricular function and the presence of mild TR. Age, atrial fibrillation, COPD, impaired renal function and elevated cardiac biomarkers were risk factors for mortality after TAVR independent from the grade of TR. Conclusions. Not only pre-interventional, but also post-TAVR high-grade TR is associated with a worse prognosis after TAVR. TAVR can change concomitant tricuspid regurgitation, but improvement does not have any impact on short- and long-term survival. Worsening of TR after TAVR is possible and impairs the prognosis.

Verified
Journal Article
Open access
PDF file
HSHatim Seoudy
Hatim Seoudy
Mohammed SaadMohammed Saad
Mohammed Saad
MSMostafa Salem
Mostafa Salem
KAKassem Allouch
Kassem Allouch
JFJohanne Frank
Johanne Frank
DFDerk Frank
Derk Frank
Background: Calculated plasma volume status (PVS) reflects volume overload based on the deviation of the estimated plasma volume (ePV) from the ideal plasma volume (iPV). Calculated PVS is associated with prognosis in the context of heart failure. This single-center study investigated the prognostic impact of PVS in patients undergoing transcatheter aortic valve implantation (TAVI). Methods: A total of 859 TAVI patients had been prospectively enrolled in an observational study and were included in the analysis. An optimal cutoff for PVS of −5.4% was determined by receiver operating characteristic curve analysis. The primary endpoint was a composite of all-cause mortality or heart failure hospitalization within 1 year after TAVI. Results: A total of 324 patients had a PVS < −5.4% (no congestion), while 535 patients showed a PVS ≥ −5.4% (congestion). The primary endpoint occurred more frequently in patients with a PVS ≥ −5.4% compared to patients with PVS < −5.4% (22.6% vs. 13.0%, p < 0.001). After multivariable adjustment, PVS was confirmed as a significant predictor of the primary endpoint (HR 1.53, 95% CI 1.05–2.22, p = 0.026). Conclusions: Elevated PVS, as a marker of subclinical congestion, is significantly associated with all-cause mortality and heart failure hospitalization within 1 year after TAVI.

10 March 2025 in Clinical Research in Cardiology
Verified
Journal Article
Open access
PDF file
Mohammed SaadMohammed Saad
Mohammed Saad
HSHatim Seoudy
Hatim Seoudy
KBK. Bramlage
K. Bramlage
PBPeter Bramlage
Peter Bramlage
JVJakob Christoph Voran
Jakob Christoph Voran
DFDerk Frank
Derk Frank
Background: Heavy calcifications in severe aortic stenosis (AS) pose a major challenge in patients undergoing transcatheter aortic valve replacement (TAVR). Only a few studies have addressed the performance of different transcatheter heart valves (THV) in this subgroup of patients. Objectives: We aimed to investigate the outcomes of the self-expanding Medtronic CoreValve Evolut valve frame and the balloon-expandable Edwards SAPIEN-3/3 Ultra THV in this challenging patient population. Materials and methods: This was a multicenter registry including a total of 1513 patients with heavily calcified AS undergoing TAVR. The primary endpoint was the incidence and degree of paravalvular leak (PVL) after TAVR. Secondary endpoints were post-implant hemodynamics as well as clinical endpoints according to the VARC-3 definitions. Results: The CoreValve Evolut R but not the Evolut PRO showed significantly higher rates of PVL compared to the SAPIEN-3/3 Ultra (44.8% vs. 29.5% for mild PVL, p < 0.001), while there was no significant difference in ≥ moderate PVL between both groups (p = 0.399). The CoreValve Evolut R and Evolut PRO showed superior THV hemodynamics compared to the SAPIEN-3/3 Ultra group. These findings were confirmed in a propensity score-matched analysis. There were no significant differences regarding short-term outcomes including permanent pacemaker implantation and all-cause mortality between the three groups. Conclusion: In patients with severely calcified AS, both CoreValve Evolut PRO and SAPIEN-3/3 Ultra THV showed lower rates of PVL than the CoreValve Evolut R. The self-expanding CoreValve platform had superior post-implant hemodynamics than the SAPIEN-3/3 Ultra system. Graphical