Xiling Zhang

Dr. Xiling Zhang


Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
Verified
Journal Article
Open access
PDF file
MNMonireh Saeid Nia
Monireh Saeid Nia
LFLena Maria Floder
Lena Maria Floder
—S— Seiler
— Seiler
TPThomas Puehler
Thomas Puehler
NPNina Sophie Pommert
Nina Sophie Pommert
GLGeorg Lutter
Georg Lutter
One of the most important medical interventions for individuals with heart valvular disease is heart valve replacement, which is not without substantial challenges, particularly for pediatric patients. Due to their biological properties and biocompatibility, natural tissue-originated scaffolds derived from human or animal sources are one type of scaffold that is widely used in tissue engineering. However, they are known for their high potential for immunogenicity. Being free of cells and genetic material, decellularized xenografts, consequently, have low immunogenicity and, thus, are expected to be tolerated by the recipient’s immune system. The scaffold ultrastructure and ECM composition can be affected by cell removal agents. Therefore, applying an appropriate method that preserves intact the structure of the ECM plays a critical role in the final result. So far, there has not been an effective decellularization technique that preserves the integrity of the heart valve’s ultrastructure while securing the least amount of genetic material left. This study demonstrates a new protocol with untraceable cells and residual DNA, thereby maximally reducing any chance of immunogenicity. The mechanical and biochemical properties of the ECM resemble those of native heart valves. Results from this study strongly indicate that different critical factors, such as ionic detergent omission, the substitution of Triton X-100 with Tergitol, and using a lower concentration of trypsin and a higher concentration of DNase and RNase, play a significant role in maintaining intact the ultrastructure and function of the ECM.

Verified
Journal Article
Open access
PDF file
XZXiling Zhang
Xiling Zhang
TPThomas Puehler
Thomas Puehler
LSLars Sondergaard
Lars Sondergaard
DFDerk Frank
Derk Frank
HSHatim Seoudy
Hatim Seoudy
GLGeorg Lutter
Georg Lutter
Over the last two decades, transcatheter devices have been developed to repair or replace diseased mitral valves (MV). Transcatheter mitral valve repair (TMVr) devices have been proven to be efficient and safe, but many anatomical structures are not compatible with these technologies. The most significant advantage of transcatheter mitral valve replacement (TMVR) over transcatheter repair is the greater and more reliable reduction in mitral regurgitation. However, there are also potential disadvantages. This review introduces the newest TMVr and TMVR devices and presents clinical trial data to identify current challenges and directions for future research.

Verified
Journal Article
Open access
PDF file
XZXiling Zhang
Xiling Zhang
TPThomas Puehler
Thomas Puehler
JSJette Seiler
Jette Seiler
Stanislav GorbStanislav Gorb
Stanislav Gorb
JSJanarthanan Sathananthan
Janarthanan Sathananthan
GLGeorg Lutter
Georg Lutter
Patients with the complex congenital heart disease (CHD) are usually associated with right ventricular outflow tract dysfunction and typically require multiple surgical interventions during their lives to relieve the right ventricular outflow tract abnormality. Transcatheter pulmonary valve replacement was used as a non-surgical, less invasive alternative treatment for right ventricular outflow tract dysfunction and has been rapidly developing over the past years. Despite the current favorable results of transcatheter pulmonary valve replacement, many patients eligible for pulmonary valve replacement are still not candidates for transcatheter pulmonary valve replacement. Therefore, one of the significant future challenges is to expand transcatheter pulmonary valve replacement to a broader patient population. This review describes the limitations and problems of existing techniques and focuses on decellularized tissue engineering for pulmonary valve stenting.

Verified
Journal Article
Open access
PDF file
XZXiling Zhang
Xiling Zhang
TPThomas Puehler
Thomas Puehler
DFDerk Frank
Derk Frank
JSJanarthanan Sathananthan
Janarthanan Sathananthan
SSStephanie Sellers
Stephanie Sellers
GLGeorg Lutter
Georg Lutter
In spite of the noninferiority of transcatheter aortic valve replacement (TAVR) in high- and intermediate-risk patients, there are still obstacles that need to be overcome before the procedure is further expanded and clinically integrated. The lack of evidence on the long-term durability of the bioprostheses used for TAVR remains of particular concern. In addition, surgery may be preferred over TAVR in patients with bicuspid aortic valve (BAV) or with concomitant pathologies such as other valve diseases (mitral regurgitation/tricuspid regurgitation), aortopathy, and coronary artery disease. In this review, we discuss and summarize relevant data from clinical trials, current trends, and remaining obstacles, and provide our perspective on the indications for the expansion of TAVR.

Verified
Journal Article
Open access
PDF file
GLGeorg Lutter
Georg Lutter
NPNina Sophie Pommert
Nina Sophie Pommert
XZXiling Zhang
Xiling Zhang
JSJette Seiler
Jette Seiler
MNMonireh Saeid Nia
Monireh Saeid Nia
JSJanarthanan Sathananthan
Janarthanan Sathananthan
Transcatheter pulmonary valve replacement is a minimally-invasive alternative treatment for right ventricular outflow tract dysfunction and has been rapidly evolving over the past years. Heart valve prostheses currently available still have major limitations. Therefore, one of the significant challenges for the future is the roll out of transcatheter tissue engineered pulmonary valve replacement to more patients. In the present study, biodegradable poly-ε-caprolactone (PCL) nanofiber scaffolds in the form of a 3D leaflet matrix were successfully seeded with human endothelial colony-forming cells (ECFCs), human induced pluripotent stem cell-derived MSCs (hMSCs), and porcine MSCs (pMSCs) for three weeks for the generation of 3D tissue-engineered tri-leaflet valved stent grafts. The cell adhesion, proliferation, and distribution of these 3D heart leaflets was analyzed using fluorescence microscopy and scanning electron microscopy (SEM). All cell lineages were able to increase the overgrown leaflet area within the three-week timeframe. While hMSCs showed a consistent growth rate over the course of three weeks, ECFSs showed almost no increase between days 7 and 14 until a growth spurt appeared between days 14 and 21. More than 90% of heart valve leaflets were covered with cells after the full three-week culturing cycle in nearly all leaflet areas, regardless of which cell type was used. This study shows that seeded biodegradable PCL nanofiber scaffolds incorporated in nitinol or biodegradable stents will offer a new therapeutic option in the future.

Verified
Journal Article
Open access
PDF file
GLGeorg Lutter
Georg Lutter
JSJulia Schütrumpf
Julia Schütrumpf
—S— Seiler
— Seiler
LJLaura Sophie Jesaitis
Laura Sophie Jesaitis
VSViktor Schneider
Viktor Schneider
MNMonireh Saeid Nia
Monireh Saeid Nia
A tissue-engineered heart valve is a fully functional tissue facilitated through the cultivation of autologous cells on appropriate scaffolds. Scaffold’s surface charge and wettability are the main factors that significantly affect cell adhesion, which is known to be favourable on hydrophilic surfaces. Moreover, biocompatible scaffolds that induce minimal immunogenic response are also essential for successful tissue engineering (TE). However, commonly used biocompatible polymers with preferable bulk properties lack desirable surface properties. For example, poly-ε-caprolactone (PCL), which is widely used as a scaffold in TE, is known for its satisfying structural and mechanical properties, but due to its surface characteristics, cell attachment and, consequently, cell growth on this polymer are limited. In this study, we investigated the possible effect of H2-N2 plasma treatment on the surface wettability of electrospun PCL nanofibres to see the feasibility of improvement in cell adhesion and proliferation. Our results showed an increase in the hydrophilicity of the 650 nm PCL specimens after plasma treatment, which was followed by a significant enhancement in cell attachment without altering PCL mechanical properties. Plasma surface modification is a promising approach that can be used to improve hiMSCs growth without altering the desired bulk properties and fibre morphology of 650 nm PCL specimens.