Andrea De Marcellis

Prof. Andrea De Marcellis

Università degli studi dell'Aquila, L’Aquila, Abruzzo, Italy
orcid

Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 June 2016 in Sensors
Verified
Journal Article
Open access
PDF file
MCMaría-Dolores Cubells-Beltrán
María-Dolores Cubells-Beltrán
Candid ReigCandid Reig
Candid Reig
JMJordi Madrenas
Jordi Madrenas
Andrea De MarcellisAndrea De Marcellis
Andrea De Marcellis
JSJoana Santos
Joana Santos
PFPaulo Freitas*
Paulo Freitas*
Less than thirty years after the giant magnetoresistance (GMR) effect was described, GMR sensors are the preferred choice in many applications demanding the measurement of low magnetic fields in small volumes. This rapid deployment from theoretical basis to market and state-of-the-art applications can be explained by the combination of excellent inherent properties with the feasibility of fabrication, allowing the real integration with many other standard technologies. In this paper, we present a review focusing on how this capability of integration has allowed the improvement of the inherent capabilities and, therefore, the range of application of GMR sensors. After briefly describing the phenomenological basis, we deal on the benefits of low temperature deposition techniques regarding the integration of GMR sensors with flexible (plastic) substrates and pre-processed CMOS chips. In this way, the limit of detection can be improved by means of bettering the sensitivity or reducing the noise. We also report on novel fields of application of GMR sensors by the recapitulation of a number of cases of success of their integration with different heterogeneous complementary elements. We finally describe three fully functional systems, two of them in the bio-technology world, as the proof of how the integrability has been instrumental in the meteoric development of GMR sensors and their applications.

17 February 2010 in Sensors and Actuators B: Chemical
Verified
Journal Article
Closed access
ADA. D’aMico
A. D’aMico
Andrea De MarcellisAndrea De Marcellis
Andrea De Marcellis
CCC. Di Carlo
C. Di Carlo
Corrado Di NataleCorrado Di Natale
Corrado Di Natale
Giuseppe FerriGiuseppe Ferri
Giuseppe Ferri
Vincenzo StornelliVincenzo Stornelli
Vincenzo Stornelli

1 June 2020 in Mechatronics
Verified
Journal Article
Closed access
MAMichele Gabrio Antonelli
Michele Gabrio Antonelli
PZPierluigi Beomonte Zobel
Pierluigi Beomonte Zobel
Andrea De MarcellisAndrea De Marcellis
Andrea De Marcellis
EPElia Palange
Elia Palange

19 October 2011 in IEEE Sensors Journal
Verified
Journal Article
Closed access
Andrea De MarcellisAndrea De Marcellis
Andrea De Marcellis
Giuseppe FerriGiuseppe Ferri
Giuseppe Ferri
ADArnaldo D'AMico
Arnaldo D'AMico
Corrado Di NataleCorrado Di Natale
Corrado Di Natale
EMEugenio Martinelli
Eugenio Martinelli
A novel fully-analog lock-in amplifier for the accurate measurements of low quantities of gas in sensor applications is here presented. When compared with commercial lock-in and other solutions available in the literature, the proposed system implements an automatic alignment of the relative phase between input and reference signals, both at power-on and for any variation of the input signal phase and amplitude during the working time, so allowing to detect, accurately and in a continuous way, the mean value of the input signal coming from sensors (typically buried into noise). The circuit has been optimized to operate at a specified reference frequency, in particular 77 Hz; this value is suitable for gas sensor applications, since it avoids also any kind of interferences at 50 Hz net frequency and its harmonics. Experimental results have confirmed the correct functionality of the system, also tested for both carbon monoxide (CO) and ethylene glycol detections. With respect to the simpler resistive gas sensor interface, implemented by a resistive voltage divider, the improvement experimentally given by the proposed automatic lock-in amplifier, in terms of resolution, has been of a factor of about 100 for the CO and 230 for the ethylene glycol measurements, so allowing a theoretical gas detection in the order of ppb.

1 June 2016 in Sensors and Actuators B: Chemical
Verified
Journal Article
Closed access
LGL. Giancaterini
L. Giancaterini
SES.M. Emamjomeh
S.M. Emamjomeh
Andrea De MarcellisAndrea De Marcellis
Andrea De Marcellis
EPElia Palange
Elia Palange
ARA. Resmini
A. Resmini
CCC. Cantalini
C. Cantalini

1 May 2011 in International Journal of Circuit Theory and Applications
Verified
Journal Article
Closed access
PDF file
Andrea De MarcellisAndrea De Marcellis
Andrea De Marcellis
CCClaudia Di Carlo
Claudia Di Carlo
Giuseppe FerriGiuseppe Ferri
Giuseppe Ferri
Vincenzo StornelliVincenzo Stornelli
Vincenzo Stornelli