Henrique Resende Martins

Prof. Henrique Resende Martins

Department of Electrical Engineering, Federal University of Minas Gerais (UFMG), Belo Horizonte, Minas Gerais, Brazil

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 January 2022 in Sensors
Verified
Journal Article
Open access
PDF file
Tiago Coelho-MagalhãesTiago Coelho-Magalhães
Tiago Coelho-Magalhães
EFEmerson Fachin-Martins
Emerson Fachin-Martins
Andressa SilvaAndressa Silva
Andressa Silva
CCChristine Azevedo Coste
Christine Azevedo Coste
HMHenrique Resende Martins
Henrique Resende Martins
Since the first Cybathlon 2016, when twelve teams competed in the FES bike race, we have witnessed a global effort towards the development of stimulation and control strategies to improve FES-assisted devices, particularly for cycling, as a means to practice a recreational physical activity. As a result, a set of technical notes and research paved the way for many other studies and the potential behind FES-assisted cycling has been consolidated. However, engineering research needs instrumented devices to support novel developments and enable precise assessment. Therefore, some researchers struggle to develop their own FES-assisted devices or find it challenging to implement their instrumentation using commercial devices, which often limits the implementation of advanced control strategies and the possibility to connect different types of sensor. In this regard, we hypothesize that it would be advantageous for some researchers in our community to enjoy access to an entire open-source FES platform that allows different control strategies to be implemented, offers greater adaptability and power capacity than commercial devices, and can be used to assist different functional activities in addition to cycling. Hence, it appears to be of interest to make our proprietary electrical stimulation system an open-source device and to prove its capabilities by addressing all the aspects necessary to implement a FES cycling system. The high-power capacity stimulation device is based on a constant current topology that allows the creation of biphasic electrical pulses with amplitude, width, and frequency up to 150 mA, 1000 µs, and 100 Hz, respectively. A mobile application (Android) was developed to set and modify the stimulation parameters of up to eight stimulation channels. A proportional-integral controller was implemented for cadence tracking with the aim to improve the overall cycling performance. A volunteer with complete paraplegia participated in the functional testing of the system. He was able to cycle indoors for 45 min, accomplish distances of more than 5 km using a passive cycling trainer, and pedal 2400 m overground in 32 min. The results evidenced the capacity of our FES cycling system to be employed as a cycling tool for individuals with spinal cord injury. The methodological strategies used to improve FES efficiency suggest the possibility of maximizing pedaling duration through more advanced control techniques.

24 November 2022 in Sensors
Verified
Journal Article
Open access
PDF file
TCTiago Coelho-Magalhães
Tiago Coelho-Magalhães
CCChristine Azevedo Coste
Christine Azevedo Coste
HMHenrique Resende Martins
Henrique Resende Martins
This study introduces a novel controller based on a Reinforcement Learning (RL) algorithm for real-time adaptation of the stimulation pattern during FES-cycling. Core to our approach is the introduction of an RL agent that interacts with the cycling environment and learns through trial and error how to modulate the electrical charge applied to the stimulated muscle groups according to a predefined policy and while tracking a reference cadence. Instead of a static stimulation pattern to be modified by a control law, we hypothesized that a non-stationary baseline set of parameters would better adjust the amount of injected electrical charge to the time-varying characteristics of the musculature. Overground FES-assisted cycling sessions were performed by a subject with spinal cord injury (SCI AIS-A, T8). For tracking a predefined pedaling cadence, two closed-loop control laws were simultaneously used to modulate the pulse intensity of the stimulation channels responsible for evoking the muscle contractions. First, a Proportional-Integral (PI) controller was used to control the current amplitude of the stimulation channels over an initial parameter setting with predefined pulse amplitude, width and fixed frequency parameters. In parallel, an RL algorithm with a decayed-epsilon-greedy strategy was implemented to randomly explore nine different variations of pulse amplitude and width parameters over the same stimulation setting, aiming to adjust the injected electrical charge according to a predefined policy. The performance of this global control strategy was evaluated in two different RL settings and explored in two different cycling scenarios. The participant was able to pedal overground for distances over 3.5 km, and the results evidenced the RL agent learned to modify the stimulation pattern according to the predefined policy and was simultaneously able to track a predefined pedaling cadence. Despite the simplicity of our approach and the existence of more sophisticated RL algorithms, our method can be used to reduce the time needed to define stimulation patterns. Our results suggest interesting research possibilities to be explored in the future to improve cycling performance since more efficient stimulation cost dynamics can be explored and implemented for the agent to learn.

1 January 2013 in Research on Biomedical Engineering
Verified
Journal Article
Open access
HMHenrique Resende Martins
Henrique Resende Martins
RZRenato Zanetti
Renato Zanetti
CSClarissa Cardoso dos Santos
Clarissa Cardoso dos Santos
GMGilberto Mastrocola Manzano
Gilberto Mastrocola Manzano
CTCarlos Julio Tierra-Criollo
Carlos Julio Tierra-Criollo
INTRODUCTION: The Perception Sensory Threshold (ST) for sinusoidal current stimuli at 5, 250, and 2,000 Hz is commonly used in the assessment of peripheral nerve fibers (C, Aδ, and Aβ, respectively). However, the neuroselectivity of these frequencies is far from consensus. In addition, Reaction Time (RT) measurements suggest that 2,000 Hz stimuli excite Aβ-fibers, 250 Hz Aβ- or Aδ-fibers, as well as 5 Hz Aβ-, Aδ- or C-fibers. Therefore, we suppose that the sinusoidal current neuroselectivity may be better observed if ST and RT parameters are jointly evaluated. In addition, we have investigated whether there are other sets of frequencies that could be used. METHODS: Thus this work investigates ST and RT for stimuli with frequency ranging from 1 to 3,000 Hz, on 28 healthy subjects aged from 19 to 44 years old (27.1±5.49). ST and RT dissimilarity among different frequencies was evaluated applying bi-dimensional Fisher Quadratic Discriminant. RESULTS: The lowest classification error (3.6%) was obtained for 1, 250, and 3,000 Hz. Error for 5, 250, and 2,000Hz was 16.7%. Stimulation frequency at 1 Hz evoked more sensations related to C-fibers (53% of reports) than to Aβ-fibers (36%). However, this behavior did not repeat itself at 5 Hz (only 21% of perceptions were related to C-fibers against 64% to Aβ-fibers). Sensations related to Aβ-fibers prevailed for the highest frequencies presented to the subjects (2,000 Hz - 82% and 3,000 Hz - 93%). Mean RT values showed a decreasing trend with frequency. CONCLUSION: These results suggest that frequencies 1, 250, and 3,000 Hz are more neuroselective than 5, 250, and 2,000 Hz for the evaluation of peripheral sensitive fibers. Furthermore, they show RT usefulness.Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)Fundação de Amparo à Pesquisa do Estado de Minas Gerais (FAPEMIG)Universidade Federal de Minas Gerais Programa de Pós-Graduação em Engenharia ElétricaUniversidade de Brasília Faculdade de CeilândiaUniversidade Federal de São Paulo (UNIFESP)Universidade Federal do Rio de Janeiro Centro de Tecnologia Programa de Engenharia BiomédicaUNIFESPSciEL

1 August 2024 in IEEE Transactions on Medical Robotics and Bionics
Verified
Journal Article
Closed access
CTClément Trotobas
Clément Trotobas
FFFernanda Márcia Rodrigues Martins Ferreira Ferreira
Fernanda Márcia Rodrigues Martins Ferreira Ferreira
JBJoão Paulo Fernandes Bonfim
João Paulo Fernandes Bonfim
MMMaria Rosália de Faria Moraes
Maria Rosália de Faria Moraes
APAdriana Maria Valladão Novais Van Pette
Adriana Maria Valladão Novais Van Pette
CCChristine Azevedo Coste
Christine Azevedo Coste

3 July 2021 in Sensors
Verified
Journal Article
Open access
PDF file
RGRonan Le Guillou
Ronan Le Guillou
MSMartin Schmoll
Martin Schmoll
BENOIT SIJOBERTBENOIT SIJOBERT
BENOIT SIJOBERT
DBDavid Lobato Borges
David Lobato Borges
EFEmerson Fachin-Martins
Emerson Fachin-Martins
CCChristine Azevedo Coste
Christine Azevedo Coste
Functional electrical stimulation (FES) is a technique used in rehabilitation, allowing the recreation or facilitation of a movement or function, by electrically inducing the activation of targeted muscles. FES during cycling often uses activation patterns which are based on the crank angle of the pedals. Dynamic changes in their underlying predefined geometrical models (e.g., change in seating position) can lead to desynchronised contractions. Adaptive algorithms with a real-time interpretation of anatomical segments can avoid this and open new possibilities for the automatic design of stimulation patterns. However, their ability to accurately and precisely detect stimulation triggering events has to be evaluated in order to ensure their adaptability to real-case applications in various conditions. In this study, three algorithms (Hilbert, BSgonio, and Gait Cycle Index (GCI) Observer) were evaluated on passive cycling inertial data of six participants with spinal cord injury (SCI). For standardised comparison, a linear phase reference baseline was used to define target events (i.e., 10%, 40%, 60%, and 90% of the cycle’s progress). Limits of agreement (LoA) of ±10% of the cycle’s duration and Lin’s concordance correlation coefficient (CCC) were used to evaluate the accuracy and precision of the algorithm’s event detections. The delays in the detection were determined for each algorithm over 780 events. Analysis showed that the Hilbert and BSgonio algorithms validated the selected criteria (LoA: +5.17/−6.34% and +2.25/−2.51%, respectively), while the GCI Observer did not (LoA: +8.59/−27.89%). When evaluating control algorithms, it is paramount to define appropriate criteria in the context of the targeted practical application. To this end, normalising delays in event detection to the cycle’s duration enables the use of a criterion that stays invariable to changes in cadence. Lin’s CCC, comparing both linear correlation and strength of agreement between methods, also provides a reliable way of confirming comparisons between new control methods and an existing reference.

1 September 2022 in Fisioterapia e Pesquisa
Verified
Journal Article
Open access
JFJanaina Almeida Fernandes
Janaina Almeida Fernandes
MSMarianne Lucena da Silva
Marianne Lucena da Silva
ATAna Cristina Trancho
Ana Cristina Trancho
JMJosé Roberto de Deus Macedo
José Roberto de Deus Macedo
HMHenrique Resende Martins
Henrique Resende Martins
PSPaulo Eugênio Silva
Paulo Eugênio Silva
Transcutaneous neuromuscular electrical stimulation (NMES) is considered an important tool to prevent muscle mass and strength loss in patients admitted to intensive care units (ICU). This study aimed to evaluate physical therapists’ profile and knowledge of NMES and identify the main barriers to its use in ICUs. This observational cross-sectional study was conducted via a structured questionnaire created by the authors. It consisted of 12 objective questions to analyze physical therapists’ knowledge of NMES use in critically ill patients. Physical therapists were invited to participate in this study during an international symposium on NMES. In total, 56 physical therapists, with a mean age of 33.5±7.2 years and working an average of 9.7±7 years after graduation, completed the survey. Overall, 34 respondents worked in ICUs, of which only four (12%) reported regular NMES use in their ICUs. We found a low average of correct answers to our questionnaire (25%; 3/12). The main barriers reported to using NMES in ICUs were lack of knowledge (28; 50%) and equipment (24; 43%). The number of correct answers expert and non-expert physical therapists was not statistically significant (p=0.68). Thus, we observed participants’ poor knowledge of NMES use in critically ill patients. Respondents showed that NMES has been underused in their ICUs. Lack of knowledge and equipment seems to be the main barriers for the use of NMES in ICUs.