Malgorzata Polacin

Dr. Malgorzata Polacin


Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 November 2022 in Diagnostics
Verified
Journal Article
Open access
PDF file
TYTetyana Yalynska
Tetyana Yalynska
MPMalgorzata Polacin
Malgorzata Polacin
Thomas FrauenfelderThomas Frauenfelder
Thomas Frauenfelder
KMKatharina Martini
Katharina Martini
Purpose: To assess the impact of virtual-monoenergetic-image (VMI) energies on the diagnosis of pulmonary embolism (PE) in photon-counting-detector computed-tomography (PCD-CT). Methods: Eighty patients (median age 60.4 years) with suspected PE were retrospectively included. Scans were performed on PCD-CT in the multi-energy mode at 120 kV. VMIs from 40–70 keV in 10 keV intervals were reconstructed. CT-attenuation was measured in the pulmonary trunk and the main branches of the pulmonary artery. Signal-to-noise (SNR) ratio was calculated. Two radiologists evaluated subjective-image-quality (noise, vessel-attenuation and sharpness; five-point-Likert-scale, non-diagnostic–excellent), the presence of hardening artefacts and presence/visibility of PE. Results: Signal was highest at the lowest evaluated VMI (40 keV; 1053.50 HU); image noise was lowest at the highest VMI (70 keV; 15.60 HU). Highest SNR was achieved at the lowest VMI (p < 0.05). Inter-reader-agreement for subjective analysis was fair to excellent (k = 0.373–1.000; p < 0.001). Scores for vessel-attenuation and sharpness were highest at 40 keV (both:5, range 4/3–5; k = 1.000); scores for image-noise were highest at 70 keV (4, range 3–5). The highest number of hardening artifacts were reported at 40 keV (n = 22; 28%). PE-visualization was rated best at 50 keV (4.7; range 4–5) and decreased with increasing VMI-energy (r = −0.558; p < 0.001). Conclusions: While SNR was best at 40 keV, subjective PE visibility was rated highest at 50 keV, potentially owing to the lower image noise and hardening artefacts.

21 July 2023 in Investigative Radiology
Verified
Journal Article
Open access
AGAna Maria Turrion Gomollon
Ana Maria Turrion Gomollon
VMVictor Mergen
Victor Mergen
TSThomas Sartoretti
Thomas Sartoretti
MPMalgorzata Polacin
Malgorzata Polacin
DNDominik Nakhostin
Dominik Nakhostin
AEAndré Euler
André Euler
Objectives: The aim of this study was to compare image quality and endoleak detection after endovascular abdominal aortic aneurysm repair between a triphasic computed tomography (CT) with true noncontrast (TNC) and a biphasic CT with virtual noniodine (VNI) images on photon-counting detector CT (PCD-CT). Materials and Methods: Adult patients after endovascular abdominal aortic aneurysm repair who received a triphasic examination (TNC, arterial, venous phase) on a PCD-CT between August 2021 and July 2022 were retrospectively included. Endoleak detection was evaluated by 2 blinded radiologists on 2 different readout sets (triphasic CT with TNC-arterial-venous vs biphasic CT with VNI-arterial-venous). Virtual noniodine images were reconstructed from the venous phase. The radiologic report with additional confirmation by an expert reader served as reference standard for endoleak presence. Sensitivity, specificity, and interreader agreement (Krippendorf α) were calculated. Image noise was assessed subjectively in patients using a 5-point scale and objectively calculating the noise power spectrum in a phantom. Results: One hundred ten patients (7 women; age, 76 ± 8 years) with 41 endoleaks were included. Endoleak detection was comparable between both readout sets with a sensitivity and specificity of 0.95/0.84 (TNC) versus 0.95/0.86 (VNI) for reader 1 and 0.88/0.98 (TNC) versus 0.88/0.94 (VNI) for reader 2. Interreader agreement for endoleak detection was substantial (TNC: 0.716, VNI: 0.756). Subjective image noise was comparable between TNC and VNI (4; IQR [4, 5] vs 4; IQR [4, 5], P = 0.44). In the phantom, noise power spectrum peak spatial frequency was similar between TNC and VNI (both fpeak = 0.16 mm−1). Objective image noise was higher in TNC (12.7 HU) as compared with VNI (11.5 HU). Conclusions: Endoleak detection and image quality were comparable using VNI images in biphasic CT as compared with TNC images in triphasic CT offering the possibility to reduce scan phases and radiation exposure.

1 January 2019 in European Journal of Radiology Open
Verified
Journal Article
Open access
MGMareike Gastl
Mareike Gastl
AGAlexander Gotschy
Alexander Gotschy
JSJochen von Spiczak
Jochen von Spiczak
MPMalgorzata Polacin
Malgorzata Polacin
FBFlorian Bönner
Florian Bönner
RMRobert Manka
Robert Manka
Hypertrophic cardiomyopathy (HCM) is characterized by a heterogeneous morphology and variable prognosis. A mismatch between left ventricular mass (LVM) and microvascular circulation with corresponding relative ischemia has been implicated to cause myocardial replacement fibrosis that deteriorates prognosis. Besides parametric T1 mapping, Cardiovascular Magnetic Resonance (CMR) T2* mapping is able to identify ischemia as well as fibrosis in cardiac and extracardiac diseases. Therefore, we aimed to investigate the value of T2* mapping to characterize structural alterations in patients with HCM. CMR was performed on a 1.5 T MR imaging system (Achieva, Philips, Best, Netherlands) using a 5-channel coil in patients with HCM (n = 103, 50.6 ± 16.4 years) and in age- and gender-matched controls (n = 20, 44.8 ± 16.9 years). T2* mapping (1 midventricular short axis slice) was acquired in addition to late gadolinium enhancement (LGE). T2* values were compared between patients with HCM and controls as well as between HCM patients with- and without fibrosis. HCM patients showed significantly decreased T2* values compared to controls (26.2 ± 4.6 vs. 31.3 ± 4.3 ms, p < 0.001). Especially patients with myocardial fibrosis presented with decreased T2* values in comparison to those without fibrosis (25.2 ± 4.0 vs. 28.7 ± 5.3 ms, p = 0.003). A regression model including maximum wall thickness, LVM and T2* values provided good overall diagnostic accuracy of 80% to diagnose HCM with and without fibrosis. In this study, parametric mapping identified lower T2* values in HCM patients compared to controls, especially in a sub-group of patients with myocardial fibrosis. As myocardial fibrosis has been suggested to influence prognosis of patients with HCM, T2* mapping may add information for identifying a higher risk sub-group of HCM patients.

18 May 2022 in BMC Cardiovascular Disorders
Verified
Journal Article
Open access
PDF file
MPMalgorzata Polacin
Malgorzata Polacin
MKMihaly Karolyi
Mihaly Karolyi
MEMatthias Eberhard
Matthias Eberhard
IMIoannis Matziris
Ioannis Matziris
HAHatem Alkadhi
Hatem Alkadhi
RMRobert Manka
Robert Manka
Background: The purpose of the study was to investigate feasibility of infarct detection in segmental strain derived from non-contrast cardiac magnetic resonance (CMR) cine sequences in patients with acute myocardial infarction (AMI) and in follow-up (FU) exams. Methods: 57 patients with AMI (mean age 61 ± 12 years, CMR 2.8 ± 2 days after infarction) were retrospectively included, FU exams were available in 32 patients (35 ± 14 days after first CMR). 43 patients with normal CMR (54 ± 11 years) served as controls. Dedicated software (Segment CMR, Medviso) was used to calculate global and segmental strain derived from cine sequences. Cine short axis stacks and segmental circumferential strain calculations of every patient and control were presented to two blinded readers in random order, who were advised to identify potentially infarcted segments, blinded to LGE and clinical information. Results: Impaired global strain was measured in AMI patients compared to controls (global peak circumferential strain [GPCS] p = 0.01; global peak longitudinal strain [GPLS] p = 0.04; global peak radial strain [GPRS] p = 0.01). In both imaging time points, mean segmental peak circumferential strain [SPCS] was impaired in infarcted tissue compared to remote segments (AMI: p = 0.03, FU: p = 0.02). SPCS values in infarcted segments were similar between AMI and FU (p = 0.8). In SPCS calculations, 141 from 189 acutely infarcted segments were accurately detected (74.6%), visual evaluation of correlating cine images detected 43.4% infarcts. In FU, 80% infarcted segments (91/114 segments) were detected in SPCS and 51.8% by visual evaluation of correlating short axis cine images (p = 0.01). Conclusion: Segmental circumferential strain derived from routinely acquired native cine sequences detects nearly 75% of acute infarcts and 80% of infarcts in subacute follow-up CMR, significantly more than visual evaluation of correlating cine images alone. Acute infarcts may display only subtle impairment of wall motion and no obvious wall thinning, thus SPCS calculation might be helpful for scar detection in patients with acute infarcts, when LGE images are not available.

4 February 2022 in European Heart Journal - Case Reports
Verified
Journal Article
Open access
PDF file
MPMalgorzata Polacin
Malgorzata Polacin
CTChristian Templin
Christian Templin
RMRobert Manka
Robert Manka
Hatem AlkadhiHatem Alkadhi
Hatem Alkadhi
A 61-year-old male with acute chest pain was referred with suspicion of acute coronary syndrome. Blood troponin T (high sensitive) was elevated (100 ng/L, norm <14 ng/L), electrocardiogram (ECG) showed no ST-elevation ( Supplementary material online , S1). Invasive coronary angiography revealed left coronary dominance with irregularities of the left anterior descending artery (LAD), but no significant stenosis or culprit lesion (Panel A). Echocardiography was normal, showing no regional wall motion abnormalities. ECG-gated computed tomography (CT) was performed using first-generation dual-source photon-counting detector CT for ruling-out pulmonary embolism and acute aortic syndrome. CT showed mild coronary calcifications (Agatston score 39) and confirmed absent obstructive coronary artery disease (PanelB). In addition, hypodense myocardium was detected in the midventricular inferolateral wall (PanelC). Dual-energy derived iodine maps from photon-counting CT overlaid onto coronary CT angiography images confirmed the area with reduced iodine concentration (PanelsD and E), yielding a reduced normalized iodine content (11.3% and 10.5% in the corresponding segments, compared to 14.3% and 12.9% in the LAD and CX territory, respectively; PanelF). Cardiac magnetic resonance imaging confirmed normal global (ejection fraction 62%) and regional left ventricular function (Video 1) and demonstrated a small ischaemic, transmural scar in the midventricular inferolateral wall in late gadolinium enhancement and native T1 maps (PanelsG–I), corresponding to the findings from photon-counting CT. Thus, myocardial infarction with non-obstructive coronary artery disease was the most probable diagnosis.

27 September 2022 in BMC Medical Imaging
Verified
Journal Article
Open access
PDF file
MPMalgorzata Polacin
Malgorzata Polacin
JGJulia Geiger
Julia Geiger
BBBarbara Burkhardt
Barbara Burkhardt
FCFraser M. Callaghan
Fraser M. Callaghan
EVEmanuela Valsangiacomo
Emanuela Valsangiacomo
CKChristian Kellenberger
Christian Kellenberger
To find the best level to measure aortic flow for quantification of aortic regurgitation (AR) in 4D flow CMR. In 27 congenital heart disease patients with AR (67% male, 31 ± 16 years) two blinded observers measured antegrade, retrograde, net aortic flow volumes and regurgitant fractions at 6 levels in 4D flow: (1) below the aortic valve (AV), (2) at the AV, (3) at the aortic sinus, (4) at the sinotubular junction, (5) at the level of the pulmonary arteries (PA) and (6) below the brachiocephalic trunk. 2D phase contrast (2DPC) sequences were acquired at the level of PA. All patients received prior transthoracic echocardiography (TTE) with AR severity grading according to a recommended multiparametric approach. After assigning 2DPC measurements into AR grading, agreement between TTE AR grading and 2DPC was good (κ = 0.88). In 4D flow, antegrade flow was similar between the six levels (p = 0.87). Net flow was higher at level 1–2 than at levels 3–6 (p < 0.05). Retrograde flow and regurgitant fraction at level 1–2 were lower compared to levels 3–6 (p < 0.05). Reproducibility (inter-reader agreement: ICC 0.993, 95% CI 0.986–0.99; intra-reader agreement: ICC 0.982, 95%CI 0.943–0.994) as well as measurement agreement between 4D flow and 2DPC (ICC 0.994; 95%CI 0.989 – 0.998) was best at the level of PA. For estimating severity of AR in 4D flow, best reproducibility along with best agreement with 2DPC measurements can be expected at the level of PA. Measurements at AV or below AV might underestimate AR.