Wenbo Huang

Wenbo Huang


Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 November 2021 in Sustainability
Verified
Journal Article
Open access
PDF file
JCJiwen Cen
Jiwen Cen
FLFeng Li
Feng Li
TLTingliang Li
Tingliang Li
Wenbo HuangWenbo Huang
Wenbo Huang
Juanwen ChenJuanwen Chen
Juanwen Chen
Fangming JiangFangming Jiang
Fangming Jiang
The installation and operation of enhanced geothermal systems (EGS) involves many challenges. These challenges include the high cost and high risk associated with the investment capital, potential large working-fluid leakage, corrosion of equipment, and subsiding land. A super-long heat pipe can be used for geothermal exploitation to avoid these problems. In this paper, a high aspect-ratio heat pipe (30 m long, 17 mm in inner diameter) is installed vertically. Experiments are then carried out to study its heat-transfer performance and characteristics using several filling ratios of deionized water, different heating powers, and various cooling-water flowrates. The results show that the optimal filling-ratio is about 40% of the volume of the vaporizing section of the heat pipe. Compared with a conventional short heat pipe, the extra-long heat pipe experiences significant thermal vibration. The oscillation frequency depends on the heating power and working-fluid filling ratio. With increasing cooling-water flow rate, the heat-transfer rate of the heat pipe increases before it reaches a plateau. In addition, we investigate the heat-transfer performance of the heat pipe for an extreme working-fluid filling ratio; the results indicate that the lower part of the heat pipe is filled with vapor, which reduces the heat-transfer to the top part. Based on the experimental data, guidelines for designing a heat pipe that can be really used for the exploitation of earth-deep geothermal energy are analyzed.

14 June 2023 in Energies
Verified
Journal Article
Open access
PDF file
FLFeng Li
Feng Li
Juanwen ChenJuanwen Chen
Juanwen Chen
JCJiwen Cen
Jiwen Cen
Wenbo HuangWenbo Huang
Wenbo Huang
ZLZhibin Li
Zhibin Li
Fangming JiangFangming Jiang
Fangming Jiang
The ultra-long gravity heat pipe has a long heat transfer distance and narrow working fluid flow channel within its tube. Due to these unique design features, the vapor–liquid counter-flow and heat transfer characteristics of these heat pipes are more complex than those found in conventional-size heat pipes. This paper innovatively proposes the design of a segmented visualization window structure of an ultra-long gravity heat pipe, which successfully overcomes the challenge of visualizing the internal flow during operations. A visualization experimental platform, measuring 40 m in height with an inner diameter of 7 mm and the aspect ratio up to 5714, was built to investigate the evolving characteristics of two-phase flows with an increasing heat input and the impact of the phase change flow characteristics on the thermal performance of ultra-long gravity heat pipes. The results obtained can provide guidance for the development of the internal structure of ultra-long gravity heat pipes that are being applied in exploiting geothermal energy. The results show that, at low heat input (200 W, 250 W), there are separate flow paths between the condensate return and the steam, but the high hydrostatic pressure due to the height of the liquid injection results in the presence of an unsaturated working fluid with a higher temperature in the liquid pool area, which has a lower evaporation rate, limiting the heat transfer through the heat pipe. It is found that if increasing the heat input up to 300 W, the evaporative phase change in the heating section becomes intense and stable. At the same time, despite the intermittent formation of liquid columns in the adiabatic section due to the vapor–liquid rolls, which increases the resistance to the vapor–liquid counter-flow, the liquid columns are blocked for a short period of time, and the path of steam rises and the condensate return is smooth, which does not seriously affect the steam condensation and liquid return evaporation. At this point, the overall temperature of the heat pipe is evenly distributed along the tube and the heat transfer performance is optimal. When the heat input further increases (350 W, 400 W), a large amount of condensate is trapped in the upper part of the adiabatic section and the condensing section by long liquid plugs for a long time. At this point, the condensate flow back to the heating section is significantly reduced, and the steam is seriously prevented from entering the condensation section, resulting in a significant increase in the temperature gradient between the lower part of the evaporating section and the upper part of the adiabatic section and deterioration of the heat transfer performance.