Raphael Vallon

Dr. Raphael Vallon

Groupe de Spectrométrie Atmosphérique (GSMA) / Université de Reims Champagne-Ardenne, Reims, France

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 November 2020 in Sensors
Verified
Journal Article
Open access
PDF file
Virginie ZéninariVirginie Zéninari
Virginie Zéninari
RVRaphael Vallon
Raphael Vallon
LBLaurent Bizet
Laurent Bizet
CJClément Jacquemin
Clément Jacquemin
GAGuillaume Aoust
Guillaume Aoust
BPBertrand Parvitte
Bertrand Parvitte
Spectroscopic techniques based on Distributed FeedBack (DFB) Quantum Cascade Lasers (QCL) provide good results for gas detection in the mid-infrared region in terms of sensibility and selectivity. The main limitation is the QCL relatively low tuning range (~10 cm−1) that prevents from monitoring complex species with broad absorption spectra in the infrared region or performing multi-gas sensing. To obtain a wider tuning range, the first solution presented in this paper consists of the use of a DFB QCL array. Tuning ranges from 1335 to 1387 cm−1 and from 2190 to 2220 cm−1 have been demonstrated. A more common technique that will be presented in a second part is to implement a Fabry–Perot QCL chip in an external-cavity (EC) system so that the laser could be tuned on its whole gain curve. The use of an EC system also allows to perform Intra-Cavity Laser Absorption Spectroscopy, where the gas sample is placed within the laser resonator. Moreover, a technique only using the QCL compliance voltage technique can be used to retrieve the spectrum of the gas inside the cavity, thus no detector outside the cavity is needed. Finally, a specific scheme using an EC coherent QCL array can be developed. All these widely-tunable Quantum Cascade-based sources can be used to demonstrate the development of optical gas sensors.

17 May 2019 in Molecules
Verified
Journal Article
Open access
PDF file
BIJAL BAHULEYANBIJAL BAHULEYAN
BIJAL BAHULEYAN
KTKathleen Toussaint
Kathleen Toussaint
HRHervé Rinnert
Hervé Rinnert
RVRaphael Vallon
Raphael Vallon
michael molinarimichael molinari
michael molinari
CCCyril Cadiou
Cyril Cadiou
A new luminescent Tb-DOTAGA (1,4,7,10-tetraazacyclododecane-1-glutaric-4,7,10- triacetic acid) complex (TbL) was synthesized and covalently immobilized on a silicon wafer. The grafting process was monitored by means of IR and XPS spectroscopies and the optical properties of the functionalized silicon wafer (TbL@Si) were investigated by fluorescence experiments. A homemade setup was then implemented in order to follow TbL@Si optical properties in the presence of gaseous nitric oxide (NO). The prima facie results indicated that in the presence of NO, the wafer fluorescence was partially quenched. This quenching was reversible as soon as NO was pumped outside the fluorescence cell, which could be interesting for the further development of lanthanide labelled silicon wafers as gas phase sensors.

2 August 2022 in Sensors
Verified
Journal Article
Open access
PDF file
FLFlorian Lecasse
Florian Lecasse
RVRaphael Vallon
Raphael Vallon
FPFrédéric Polak
Frédéric Polak
CCClara Cilindre
Clara Cilindre
BPBertrand Parvitte
Bertrand Parvitte
Virginie ZéninariVirginie Zéninari
Virginie Zéninari
In wine tasting, tasters commonly swirl their glasses before inhaling the headspace above the wine. However, the consequences of wine swirling on the chemical gaseous headspace inhaled by tasters are barely known. In champagne or sparkling wine tasting, starting from the pouring step, gas-phase carbon dioxide (CO2) is the main gaseous species that progressively invades the glass headspace. We report the development of a homemade orbital shaker to replicate wine swirling and the upgrade of a diode laser sensor (DLS) dedicated to monitoring gas-phase CO2 in the headspace of champagne glasses under swirling conditions. We conduct a first overview of gas-phase CO2 monitoring in the headspace of a champagne glass, starting from the pouring step and continuing for the next 5 min, with several 5 s swirling steps to replicate the natural orbital movement of champagne tasters. The first results show a sudden drop in the CO2 concentration in the glass headspace, probably triggered by the liquid wave traveling along the glass wall following the action of swirling the glass.

7 July 2025 in Sensors and Actuators B: Chemical
Verified
Journal Article
Open access
FLFlorian Lecasse
Florian Lecasse
RVRaphael Vallon
Raphael Vallon
CJClement Jacquemin
Clement Jacquemin
VAVincent Alfonso
Vincent Alfonso
CCClara Cilindre
Clara Cilindre
GLGérard Liger-Belair
Gérard Liger-Belair

1 May 2016 in Infrared Physics & Technology
Verified
Journal Article
Closed access
RVRaphael Vallon
Raphael Vallon
BPBertrand Parvitte
Bertrand Parvitte
LBLaurent Bizet
Laurent Bizet
GNGuy Mael De Naurois
Guy Mael De Naurois
BSBouzid Simozrag
Bouzid Simozrag
Virginie ZéninariVirginie Zéninari
Virginie Zéninari

8 April 2024 in OENO One
Verified
Journal Article
Open access
PDF file
VAVincent Alfonso
Vincent Alfonso
FLFlorian Lecasse
Florian Lecasse
RVRaphael Vallon
Raphael Vallon
CCClara Cilindre
Clara Cilindre
BPBertrand Parvitte
Bertrand Parvitte
GLGérard Liger-Belair
Gérard Liger-Belair
Champagne wines are complex hydroalcoholic mixtures supersaturated with dissolved carbon dioxide (CO2). During tasting, while serving the champagne in a glass and for the few minutes that follow, the headspace of the glass is progressively invaded by many chemical species, including gas–phase CO2 (likely to disrupt the perception of the wine’s bouquet beyond a certain threshold). Real-time monitoring of gas–phase CO2 was performed through tunable diode laser absorption spectroscopy along a multipoint network in the headspace of two champagne glasses showing distinct shapes and volume capacities (namely, the standard 21 cL INAO glass and the brand new 45 cL ŒnoXpert glass, designed by the Union of French Oenologists as a universal glass for the tasting of still and sparkling wines). From the start of the pouring stage and during the several minutes following, a kind of glass type-dependent CO2 footprint was revealed in the headspace of glasses, which was discussed based on the glass geometry and headspace volume. For an identical volume of champagne dispensed in both glasses, the headspace of ŒnoXpert was found to retain gaseous CO2 more efficiently over time than INAO glass does. Therefore, and extrapolating to aromatic compounds, the chemical space of the ŒnoXpert glass should be better preserved throughout the tasting than that of the INAO glass. Moreover, by reducing the volume of champagne served in the glass, the time-dependent CO2 footprint is significantly reduced in the glass headspace, thus reducing the risk of carbon dioxide burn during tasting.