Tony Yuan

Dr. Tony Yuan


Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 October 2016 in Journal of Nanomaterials
Verified
Journal Article
Open access
PDF file
TYTony Yuan
Tony Yuan
PJPhillip M. Jenkins
Phillip M. Jenkins
AFAnn Marie DiGeorge Foushee
Ann Marie DiGeorge Foushee
AJAngela R. Jockheck-Clark
Angela R. Jockheck-Clark
JSJonathan M. Stahl
Jonathan M. Stahl
Electrospinning is a simple and versatile technique for the fabrication of nonwoven fibrous materials for biomedical applications. In the present study, chitosan (CS) and polyethylene oxide (PEO) nanofibrous scaffolds were successfully prepared using three different CS/PEO mass ratios and then evaluated for their physical, chemical, and biological characteristics. Scaffold morphologies were observed by scanning electron microscopy, which showed decreasing fiber diameters with increasing CS content. Higher CS concentrations also correlated with increased tensile strength and decreased elasticity of the scaffold. Degradation studies demonstrated that PEO was solubilized from the scaffold within the first six hours, followed by CS. This profile was unaffected by changes in the CS/PEO ratio or the pH of the media. Only the 2 : 1 CS/PEO scaffold demonstrated superior inhibition of both growth and attachment of Staphylococcus aureus. Finally, all scaffolds exhibited little impact on the proliferation of murine fibroblast monolayers. These data demonstrate that the 2 : 1 CS/PEO scaffold is a promising candidate for wound dressing applications due to its excellent antibacterial characteristics and biocompatibility.

25 January 2024 in Bioengineering
Verified
Journal Article
Open access
PDF file
CHCarrie W. Hoppes
Carrie W. Hoppes
KLKaren H. Lambert
Karen H. Lambert
SWSusan L Whitney
Susan L Whitney
IEIsaac D. Erbele
Isaac D. Erbele
CECarlos Esquivel
Carlos Esquivel
TYTony Yuan
Tony Yuan
Introduction: The vestibular system, essential for gaze and postural stability, can be damaged by threats on the battlefield. Technology can aid in vestibular assessment and rehabilitation; however, not all devices are conducive to the delivery of healthcare in an austere setting. This scoping review aimed to examine the literature for technologies that can be utilized for vestibular assessment and rehabilitation in operational environments. Materials and Methods: A comprehensive search of PubMed was performed. Articles were included if they related to central or peripheral vestibular disorders, addressed assessment or rehabilitation, leveraged technology, and were written in English. Articles were excluded if they discussed health conditions other than vestibular disorders, focused on devices or techniques not conducive to the operational environment, or were written in a language other than English. Results: Our search strategy yielded 32 articles: 8 articles met our inclusion and exclusion criteria whereas the other 24 articles were rejected. Discussion: There is untapped potential for leveraging technology for vestibular assessment and rehabilitation in the operational environment. Few studies were found in the peer-reviewed literature that described the application of technology to improve the identification of central and/or peripheral vestibular system impairments; triage of acutely injured patients; diagnosis; delivery and monitoring of rehabilitation; and determination of readiness for return to duty. Conclusions: This scoping review highlighted technology for vestibular assessment and rehabilitation feasible for use in an austere setting. Such technology may be leveraged for prevention; monitoring exposure to mechanisms of injury; vestibular-ocular motor evaluation; assessment, treatment, and monitoring of rehabilitation progress; and return-to-duty determination after vestibular injury. Future Directions: The future of vestibular assessment and rehabilitation may be shaped by austere manufacturing and 3D printing; artificial intelligence; drug delivery in combination with vestibular implantation; organ-on-chip and organoids; cell and gene therapy; and bioprinting.

17 February 2022 in Journal of Clinical Laboratory Analysis
Verified
Journal Article
Open access
PDF file
ASAntonio O. Sanchez
Antonio O. Sanchez
AOAnna R. Ochoa
Anna R. Ochoa
SHSallie L. Hall
Sallie L. Hall
CVChet R. Voelker
Chet R. Voelker
RMRachel E. Mahoney
Rachel E. Mahoney
TYTony Yuan
Tony Yuan
Introduction: The World Health Organization (WHO) declared coronavirus disease 2019 (COVID‐19) a pandemic in March 2020. Initially, supply chain disruptions and increased demand for testing led to shortages of critical laboratory reagents and inadequate testing capacity. Thus, alternative means of biosample collection and testing were essential to overcome these obstacles and reduce viral transmission. This study aimed to 1) compare the sensitivity and specificity of Cepheid GeneXpert® IV and BioFire® FilmArray® 2.0 next generation detection systems to detect SARS‐CoV‐2, 2) evaluate the performance of both platforms using different biospecimen types, and 3) assess saline as an alternative to viral transport media (VTM) for sample collection.Methods: A total of 1,080 specimens consisting of nasopharyngeal (NP) swabs in VTM, NP swabs in saline, nasal swabs, oropharyngeal (OP) swabs, and saliva were collected from 216 enrollees. Limit of detection (LoD) assays, NP VTM and NP saline concordance, and saliva testing were performed on the BioFire® FilmArray® 2.0 Respiratory Panel 2.1 and Cepheid GeneXpert® Xpress SARS‐CoV‐2/Flu/RSV assays.Results: LoD and comparative testing demonstrated increased sensitivity with the Cepheid compared with the BioFire® in detecting SARS‐CoV‐2 in NP VTM and saline, nasal, and OP swabs. Conversely, saliva testing on the Cepheid showed statistically significant lower sensitivity compared to the BioFire®. Finally, NP swabs in saline showed no significant difference compared with NP swabs in VTM on both platforms.Conclusion: The Cepheid and BioFire® NGDS are viable options to address a variety of public health needs providing rapid and reliable, point‐of‐care testing using a variety of clinical matrices.

KWKaren Weis
Karen Weis
TYTony Yuan
Tony Yuan
KWKatherine Walker
Katherine Walker
TGThomas Gibbons
Thomas Gibbons
WCWenyaw Chan
Wenyaw Chan
Stress and anxiety significantly impact the hypothalamic–pituitary axis, and in pregnancy, the subsequent maternal–fetal response can lead to poor outcomes. The objective of this study was to assess the association between psychosocial measures of pregnancy-specific anxiety and physiologic inflammatory responses. Specifically, to determine the effectiveness of the Mentors Offering Maternal Support (M-O-M-STM) program to reduce psychosocial anxiety and associated inflammatory response. In conjunction with measures of pregnancy-specific anxiety and depression, serum biomarkers (IL-2, IL-6, IL-10, IL1-B, TNF-α, CRH, CRP, and cortisol) were analyzed for each trimester throughout pregnancy. Results demonstrated that women receiving the M-O-M-STM intervention had longitudinally sustained lower TNF-α/IL-10 ratios than the control group, and it was significantly associated with psychosocial measures of anxiety, specifically for fears of labor and spouse/partner relationships. Additionally, the anxiety of spouse/partner relationships was significantly associated with IL-6/IL-10 ratios. The findings highlight the important counter-regulatory relationship between anti- and pro-inflammatory cytokines and provide insight into the distinct physiologic responses to pregnancy-specific anxiety with early prenatal intervention.

5 February 2024 in Bioengineering
Verified
Journal Article
Open access
PDF file
MDMikalyn T DeFoor
Mikalyn T DeFoor
DCDaniel J. Cognetti
Daniel J. Cognetti
TYTony Yuan
Tony Yuan
ASAndrew J. Sheean
Andrew J. Sheean
Tendon injuries in military servicemembers are one of the most commonly treated nonbattle musculoskeletal injuries (NBMSKIs). Commonly the result of demanding physical training, repetitive loading, and frequent exposures to austere conditions, tendon injuries represent a conspicuous threat to operational readiness. Tendon healing involves a complex sequence between stages of inflammation, proliferation, and remodeling cycles, but the regenerated tissue can be biomechanically inferior to the native tendon. Chemical and mechanical signaling pathways aid tendon healing by employing growth factors, cytokines, and inflammatory responses. Exosome-based therapy, particularly using adipose-derived stem cells (ASCs), offers a prominent cell-free treatment, promoting tendon repair and altering mRNA expression. However, each of these approaches is not without limitations. Future advances in tendon tissue engineering involving magnetic stimulation and gene therapy offer non-invasive, targeted approaches for improved tissue engineering. Ongoing research aims to translate these therapies into effective clinical solutions capable of maximizing operational readiness and warfighter lethality.

1 March 2024 in Bioengineering
Verified
Journal Article
Open access
PDF file
DCDaniel J. Cognetti
Daniel J. Cognetti
MDMikalyn T DeFoor
Mikalyn T DeFoor
TYTony Yuan
Tony Yuan
ASAndrew J. Sheean
Andrew J. Sheean
The unique physical demands of tactical athletes put immense stress on the knee joint, making these individuals susceptible to injury. In order to ensure operational readiness, management options must restore and preserve the native architecture and minimize downtime, while optimizing functionality. Osteochondral lesions (OCL) of the knee have long been acknowledged as significant sources of knee pain and functional deficits. The management of OCL is predicated on certain injury characteristics, including lesion location and the extent of subchondral disease. Techniques such as marrow stimulation, allograft and autologous chondrocyte implantation are examined in detail, with a focus on their application and suitability in tactical athlete populations. Moreover, the restoration of the osteochondral unit (OCU) is highlighted as a central aspect of knee joint preservation. The discussion encompasses the biomechanical considerations and outcomes associated with various cartilage restoration techniques. Factors influencing procedure selection, including lesion size, location, and patient-specific variables, are thoroughly examined. Additionally, the review underscores the critical role of post-operative rehabilitation and conditioning programs in optimizing outcomes. Strengthening the surrounding musculature, enhancing joint stability, and refining movement patterns are paramount in facilitating the successful integration of preservation procedures. This narrative review aims to provide a comprehensive resource for surgeons, engineers, and sports medicine practitioners engaged in the care of tactical athletes and the field of cartilage restoration. The integration of advanced preservation techniques and tailored rehabilitation protocols offers a promising avenue for sustaining knee joint health and function in this demanding population.