Phillip M. Jenkins

Phillip M. Jenkins

Auto-generated profile, based on publicly available information

Phillip M. Jenkins

Division of Trauma Surgery and Surgical Critical Care, Department of General Surgery, Hurley Medical Center, MI, USA

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 June 2015 in Discover Nano
Verified
Journal Article
Open access
PDF file
PJPhillip M Jenkins
Phillip M Jenkins
MLMelissa R Laughter
Melissa R Laughter
DLDavid J Lee
David J Lee
YLYoung M Lee
Young M Lee
CFCurt R Freed
Curt R Freed
DPDaewon Park
Daewon Park
Despite major advances in the pathophysiological understanding of peripheral nerve damage, the treatment of nerve injuries still remains an unmet medical need. Nerve guidance conduits present a promising treatment option by providing a growth-permissive environment that 1) promotes neuronal cell survival and axon growth and 2) directs axonal extension. To this end, we designed an electrospun nerve guidance conduit using a blend of polyurea and poly-caprolactone with both biochemical and topographical cues. Biochemical cues were integrated into the conduit by functionalizing the polyurea with RGD to improve cell attachment. Topographical cues that resemble natural nerve tissue were incorporated by introducing intraluminal microchannels aligned with nanofibers. We determined that electrospinning the polymer solution across a two electrode system with dissolvable sucrose fibers produced a polymer conduit with the appropriate biomimetic properties. Human neural stem cells were cultured on the conduit to evaluate its ability to promote neuronal growth and axonal extension. The nerve guidance conduit was shown to enhance cell survival, migration, and guide neurite extension.

19 October 2016 in Journal of Nanomaterials
Verified
Journal Article
Open access
PDF file
TYTony Yuan
Tony Yuan
PJPhillip M. Jenkins
Phillip M. Jenkins
AFAnn Marie DiGeorge Foushee
Ann Marie DiGeorge Foushee
AJAngela R. Jockheck-Clark
Angela R. Jockheck-Clark
JSJonathan M. Stahl
Jonathan M. Stahl
Electrospinning is a simple and versatile technique for the fabrication of nonwoven fibrous materials for biomedical applications. In the present study, chitosan (CS) and polyethylene oxide (PEO) nanofibrous scaffolds were successfully prepared using three different CS/PEO mass ratios and then evaluated for their physical, chemical, and biological characteristics. Scaffold morphologies were observed by scanning electron microscopy, which showed decreasing fiber diameters with increasing CS content. Higher CS concentrations also correlated with increased tensile strength and decreased elasticity of the scaffold. Degradation studies demonstrated that PEO was solubilized from the scaffold within the first six hours, followed by CS. This profile was unaffected by changes in the CS/PEO ratio or the pH of the media. Only the 2 : 1 CS/PEO scaffold demonstrated superior inhibition of both growth and attachment of Staphylococcus aureus. Finally, all scaffolds exhibited little impact on the proliferation of murine fibroblast monolayers. These data demonstrate that the 2 : 1 CS/PEO scaffold is a promising candidate for wound dressing applications due to its excellent antibacterial characteristics and biocompatibility.

4 February 2022 in American Journal of Infection Control
Verified
Journal Article
Open access
RBRoxanne Buterakos
Roxanne Buterakos
PJPhillip M Jenkins
Phillip M Jenkins
JCJames Cranford
James Cranford
RHRobert Stephen Haake
Robert Stephen Haake
MMMichelle Maxson
Michelle Maxson
GSGul R Sachwani-Daswani
Gul R Sachwani-Daswani
Ventilator-associated pneumonia (VAP) is considered the most common hospital acquired infection seen in critical care settings and leading cause of death in Intensive Care Units (ICU). The objective of this study was to assess whether specimen collection impacted diagnosis and if implementation of a VAP bundle would decrease rates at our center. This single center study design is a retrospective chart review from 2017 to 2020 utilizing the electronic medical record. A pre-/postintervention comparison was performed following implementation of a unit wide VAP bundle and nursing education. Descriptive statistics and continuous variables were analyzed with independent group t -tests, and categorical variables were analyzed with chi-squared tests. Ventilator-associated pneumonia rates decreased in the postimplementation time (20.8%, n = 74 vs 12.2%, n = 15; P = .03). There were no significant differences in the patient profile of those who acquired VAP (ie, males 79.7% vs 86.7%, blunt injuries 63.5% vs 86.7% and severity scores 24.8 vs 25.1, pre vs postimplementation, respectively, all P-values greater than .05). Reduction in VAP rates were achieved by implementing a standardized, evidence based, prevention protocol. Further research is warranted as studies have noted that patients requiring mechanical ventilation are at greater risk for VAP than other ICU patients due to the nature of their injuries and increased risk of prolonged mechanical ventilation ≥ 21 days.

25 November 2013 in Journal of Biomaterials Science, Polymer Edition
Verified
Journal Article
Closed access
DYDonghwa Yun
Donghwa Yun
AFAmin Famili
Amin Famili
YLYoung Mook Lee
Young Mook Lee
PJPhillip M. Jenkins
Phillip M. Jenkins
CFCurt R. Freed
Curt R. Freed
DPDaewon Park
Daewon Park
Nerve function recovery is a major technical challenge in the rehabilitation of patients suffering from severe neuropathies. Facilitating functional recovery requires the creation of a growth-permissive environment that directs the extension and myelination of surviving neurons. To this end, an electrospun nanofiber scaffold composed of arginine–glycine–aspartate-modified poly(serinol hexamethylene urea)-blend-poly-ε-caprolactone (PSHU-RGD/PCL) has been employed. Initially, we investigated the cytotoxicity of PSHU in PC12 cell culture. This was followed by functional examinations of PSHU-RGD for cell viability, proliferation, differentiation, and neurite outgrowth, and finally we examined electrospun scaffolds for guided neurite sprouting. MTT proliferation assays indicated no cytotoxic effects of polymer as compared to laminin-coated surfaces. Functional testing revealed PSHU-RGD surfaces to be comparable to the positive control, laminin-coated surface, in neurite outgrowth studies with average neurite lengths of 84.6 μm (laminin), 218.2 μm (PSHU-RGD), 570.2 μm (laminin + NGF), and 958.2 μm (PSHU-RGD + NGF) after two weeks on homogeneously modified surfaces, and 554.8 μm (nonwoven mats) and 1512.3 μm (uniaxially aligned mats) for PSHU-RGD/PCL + NGF scaffolds after one week. We created PSHU functionalized with the tripeptide, RGD, which provided chemical and physical cues to PC12 cell proliferation and differentiation. We expect that PSHU-RGD will be capable of directing and promoting neurite outgrowth in many neuropathy models.

20 February 2021 in Journal of Burn Care & Research
Verified
Journal Article
Open access
PDF file
PJPhillip M Jenkins
Phillip M Jenkins
FDFadi Al Daoud
Fadi Al Daoud
LMLeo Mercer
Leo Mercer
DSDonald Scholten
Donald Scholten
KWKristoffer Wong
Kristoffer Wong
GSGul R Sachwani-Daswani
Gul R Sachwani-Daswani
Nucleated red blood cells (NRBCs) have been studied in critically ill and injured patients as a predictor of increased in-hospital mortality and poor clinical outcomes. While prior studies have demonstrated the prognostic power of NRBCs in the critical patient, there has been a paucity of literature available describing their value as a prognostic indicator in the severely burned patient. This retrospective observational study was conducted from 2012 to 2017. Inclusion criteria for this study included all burn patients with total body surface area > 10% who were aged ≥ 15 years. Demographic and clinical data were collected from the electronic medical record system. Data analysis consisted of descriptive and comparative analysis using SPSS. Two hundred and nineteen patients (17.5%) met inclusion criteria with 51 (23.3%) patients positive for NRBCs. The presence of NRBCs had an increased mortality rate with an odds ratio of 6.0 (P = .001; 2.5, 14.5); was more likely to appear in older patients (P < .001); and was associated with increased hospital length of stay (P < .001), injury severity scores (P < .001), and complications. The presence of NRBCs even at the low concentrations reported in our study showed a 6-fold increase in the rate of mortality. With the current improvements in burn care leading to higher survival rates, the need to improve upon the numerous models that have been developed to predict mortality in severe burn patients is clear given the significantly increased risk of death that the presence of NRBCs portends.

30 March 2022 in Violence and Victims
Verified
Journal Article
Closed access
PDF file
JMJennifer L. Mercer
Jennifer L. Mercer
JRJori A. Reigle
Jori A. Reigle
PJPhillip M. Jenkins
Phillip M. Jenkins
JCJames A. Cranford
James A. Cranford
CCConstance J. Creech
Constance J. Creech
LMLeo C. Mercer
Leo C. Mercer
Background Wraparound referrals are a cornerstone of hospital-based violence intervention programs, which have proven to be an effective public health approach for mitigating violence and recidivism. We hypothesized that replacing a manual referral process with an electronic referral application would increase the number of generated referrals and improve compliance with follow-up visits. Study Design The population for this single center quantitative study was a convenience sample of firearm-injured patients. Data from 74 patients were collected using the electronic health record, the electronic referral application, and the trauma registry before and after the intervention. Results Post-implementation of the electronic referral application showed an increased number of generated referrals, increased emergency department and inpatient utilization of trauma recovery center services, and an increase in second follow-up visit compliance. Conclusion This study demonstrated an increase in the number of referrals and greater likelihood of completion of post-injury follow-up visits after implementing the electronic referral system.