Suchit Kumar

Dr. Suchit Kumar

Korea University
orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 August 2021 in Applied Sciences
Verified
Journal Article
Open access
PDF file
SKSuchit Kumar
Suchit Kumar
HCHan-Jae Chung
Han-Jae Chung
YJYou-Jin Jeong
You-Jin Jeong
HLHeung-Kyu Lee
Heung-Kyu Lee
COChang-Hyun Oh
Chang-Hyun Oh
The feasibility and the development of a four-port elliptical birdcage radio frequency (RF) coil for generating a homogenous RF magnetic (B1) field is presented for a space-constrained narrow-bore magnetic resonance imaging (MRI) system. Optimization was performed for the elliptical birdcage RF coil by adjusting the position and the structure of the legs to maximize the B1+-field uniformity. Electromagnetic (EM) simulations based on RF coil circuit co-simulations were performed on a cylindrical uniform phantom and a three-dimensional human model to evaluate the B1+-field uniformity, the transmission efficiency, and the specific absorption rate (SAR) deposition. An elliptical birdcage RF coil was constructed, and its performance was evaluated through network analysis measurements such as S-parameters and Q-factor. Quadrature transmit and receive MRI experiments were conducted using both phantom and in vivo human for validation. The EM simulation results indicate reasonable B1+-field uniformity and transmission efficiency for the proposed elliptical birdcage RF coil. The signal-to-noise ratio and the flip angle maps of the uniform phantom and the in vivo human MR images acquired using an elliptical birdcage (62 cm × 58 cm) were similar to those of a commercial circular birdcage (diameter, 58 cm), thereby indicating acceptable performance. In conclusion, the proposed split-type asymmetric elliptical birdcage RF coil is useful for whole-body MRI applications and can be used for imaging larger human subjects comfortably in a spacious imaging space.

13 December 2023 in Applied Sciences
Verified
Journal Article
Open access
PDF file
YJYou-Jin Jeong
You-Jin Jeong
SKSuchit Kumar
Suchit Kumar
SPSeon-Woo Park
Seon-Woo Park
YSYoungkyu Song
Youngkyu Song
KIKorea Basic Science Institute
Korea Basic Science Institute
COChang-Hyun Oh
Chang-Hyun Oh
This study presents the feasibility of a dual-mode high-pass birdcage RF coil to acquire MR images at both 1H and 23Na frequencies at ultra-high-field MR scanner, 7 T. A dual-mode circuit (DMC) in the dual-mode birdcage (DMBC) RF coil operates at two frequencies, addressing the limitations of sensitivity reduction and isolation between two frequencies as in traditional dual-tuned RF coil. Finite-difference time-domain (FDTD) based electromagnetic (EM) simulations were performed to verify the RF coil at each frequency on the three-dimensional human head model. The DMBC RF coil resonated at proton (1H) and sodium (23Na) frequencies, and also single-tuned high-pass birdcage RF coils were constructed for both 1H and 23Na frequencies. The bench test performance of the RF coils was evaluated using network analysis parameters, including the measurement of scattering parameters (S-parameters) and quality factors (Q-factors). Q-factor of the DMBC coil at 1H port was 10.2% lower than that of 1H single-tuned birdcage (STBC) coil, with a modest SNR reduction of 6.5%. Similarly, the Q-factor for the DMBC coil at 23Na port was 12.3% less than that of 23Na STBC coil, and the SNR showed a minimal reduction of 5.4%. Utilizing the DMBC coil, promising 1H and 23Na MR images were acquired compared to those by using STBC coils. In conclusion, deploying a DMBC 1H/23Na coil has been demonstrated to overcome traditional constraints associated with dual-tuned RF coils, achieving this with only nominal signal attenuation across both nuclei operational frequencies.

24 May 2025 in Bioengineering
Verified
Journal Article
Open access
PDF file
HHHassan B. Hawsawi
Hassan B. Hawsawi
APAnastasia Papadaki
Anastasia Papadaki
VVVejay N. Vakharia
Vejay N. Vakharia
JTJohn S. Thornton
John S. Thornton
DCDavid W Carmichael
David W Carmichael
LLLouis Lemieux
Louis Lemieux
The acquisition of electroencephalography (EEG) concurrently with functional magnetic resonance imaging (fMRI) requires a careful consideration of the health hazards resulting from interactions between the scanner’s electromagnetic fields and EEG recording equipment. The primary safety concern is excessive RF-induced heating of the tissue in the vicinity of electrodes. We have previously demonstrated that concurrent intracranial EEG (icEEG) and fMRI data acquisitions (icEEG-fMRI) can be performed with acceptable risk in specific conditions using a head RF transmit coil. Here, we estimate the potential additional heating associated with the addition of scalp EEG electrodes using a body transmit RF coil. In this study, electrodes were placed in clinically realistic positions on a phantom in two configurations: (1) icEEG electrodes only, and (2) following the addition of subdermal scalp electrodes. Heating was measured during MRI scans using a body transmit coil with a high specific absorption rate (SAR), TSE (turbo spin echo), and low SAR gradient-echo EPI (echo-planar imaging) sequences. During the application of the high-SAR sequence, the maximum temperature change for the intracranial electrodes was +2.8 °C. The addition of the subdural scalp EEG electrodes resulted in a maximum temperature change for the intracranial electrodes of 2.1 °C and +0.6 °C across the scalp electrodes. For the low-SAR sequence, the maximum temperature increase across all intracranial and scalp electrodes was +0.7 °C; in this condition, the temperature increases around the intracranial electrodes were below the detection level. Therefore, in the experimental conditions (MRI scanner, electrode, and wire configurations) used at our centre for icEEG-fMRI, adding six scalp EEG electrodes did not result in significant additional localised RF-induced heating compared to the model using icEEG electrodes only.

11 April 2022 in Journal of the Korean Physical Society
Verified
Journal Article
Closed access
PDF file
SKSuchit Kumar
Suchit Kumar
JYJun-Sik Yoon
Jun-Sik Yoon
JKJong-Min Kim
Jong-Min Kim
CLChulhyun Lee
Chulhyun Lee
COChang-Hyun Oh
Chang-Hyun Oh

1 January 2023 in Investigative Magnetic Resonance Imaging
Verified
Journal Article
Open access
PDF file
SKSuchit Kumar
Suchit Kumar
JKJong-Min Kim
Jong-Min Kim
JCJang Gyu Cha
Jang Gyu Cha
JHJi Young Hwang
Ji Young Hwang
SJSeung Eun Jung
Seung Eun Jung
COChang-Hyun Oh
Chang-Hyun Oh
Kumar S, et al. Investig Magn Reson Imaging. 2023 Mar;27(1):10-20. https://doi.org/10.13104/imri.2022.1009

13 April 2023 in Concepts in Magnetic Resonance Part A
Verified
Journal Article
Open access
PDF file
SKSuchit Kumar
Suchit Kumar
KLKyu Chan Lee
Kyu Chan Lee
JKJong-Min Kim
Jong-Min Kim
JSJeunghoon Seo
Jeunghoon Seo
CLChulhyun Lee
Chulhyun Lee
COChang-Hyun Oh
Chang-Hyun Oh
Radiofrequency (RF) transmit field (B1) mapping is a promising method in mitigating the B1 inhomogeneity in various magnetic resonance imaging (MRI) applications. Although several phase- or magnitude-based B1 mapping methods have been proposed, these methods often require complex modeling, long acquisition time, or specialized MRI sequences. A recently introduced simultaneous echo refocusing (SER) technique can be applied in the B1 mapping method to extend the three-dimensional (3D) spatial coverage only without long data acquisition. Therefore, in this study, a multislice B1 mapping method using composite spin echo sequences and SER techniques is proposed to obtain more accurate B1 mapping with short data acquisition time. To evaluate the performance of the proposed B1 mapping method, computational simulations were performed and compared with Morrells method, double angle method, and Yarnykhs method. These results showed that the angle-to-noise ratio of the proposed B1 mapping method has wider B1 range compared to that of other B1 mapping methods. In addition, the proposed B1 mapping methods were compared to the multislice iterative signal intensity mapping method in both phantom and in vivo human experiments, and there was no remarkable difference between the two methods regarding the flip angle distribution in these experiments. Based on these results, this study demonstrated that the proposed B1 mapping method is suitable for accurately measuring B1 propagation under the condition providing reduced scan time and wider 3D coverage of B1 mapping by applying composite RF pulse and SER techniques into the phase-sensitive method.