Chang-Hyun Oh

Prof. Chang-Hyun Oh

orcid

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2017 in Biochemical and Biophysical Research Communications
Verified
Journal Article
Closed access
CMChung-Man Moon
Chung-Man Moon
COChang-Hyun Oh
Chang-Hyun Oh
KAKyu-Youn Ahn
Kyu-Youn Ahn
JYJun-Seok Yang
Jun-Seok Yang
JKJae-Young Kim
Jae-Young Kim
GJGwang-Woo Jeong
Gwang-Woo Jeong

13 August 2021 in Applied Sciences
Verified
Journal Article
Open access
PDF file
SKSuchit Kumar
Suchit Kumar
HCHan-Jae Chung
Han-Jae Chung
YJYou-Jin Jeong
You-Jin Jeong
HLHeung-Kyu Lee
Heung-Kyu Lee
COChang-Hyun Oh
Chang-Hyun Oh
The feasibility and the development of a four-port elliptical birdcage radio frequency (RF) coil for generating a homogenous RF magnetic (B1) field is presented for a space-constrained narrow-bore magnetic resonance imaging (MRI) system. Optimization was performed for the elliptical birdcage RF coil by adjusting the position and the structure of the legs to maximize the B1+-field uniformity. Electromagnetic (EM) simulations based on RF coil circuit co-simulations were performed on a cylindrical uniform phantom and a three-dimensional human model to evaluate the B1+-field uniformity, the transmission efficiency, and the specific absorption rate (SAR) deposition. An elliptical birdcage RF coil was constructed, and its performance was evaluated through network analysis measurements such as S-parameters and Q-factor. Quadrature transmit and receive MRI experiments were conducted using both phantom and in vivo human for validation. The EM simulation results indicate reasonable B1+-field uniformity and transmission efficiency for the proposed elliptical birdcage RF coil. The signal-to-noise ratio and the flip angle maps of the uniform phantom and the in vivo human MR images acquired using an elliptical birdcage (62 cm × 58 cm) were similar to those of a commercial circular birdcage (diameter, 58 cm), thereby indicating acceptable performance. In conclusion, the proposed split-type asymmetric elliptical birdcage RF coil is useful for whole-body MRI applications and can be used for imaging larger human subjects comfortably in a spacious imaging space.

7 February 2018 in Scientific Reports
Verified
Journal Article
Open access
PDF file
DLDan Bi Lee
Dan Bi Lee
JKJong-Min Kim
Jong-Min Kim
JSJong Hyeon Seok
Jong Hyeon Seok
JLJi-Hye Lee
Ji-Hye Lee
JJJae Deok Jo
Jae Deok Jo
KKKyung Hyun Kim
Kyung Hyun Kim
Time-resolved serial femtosecond crystallography with X-ray free electron laser (XFEL) holds the potential to view fast reactions occurring at near-physiological temperature. However, production and characterization of homogeneous micron-sized protein crystals at high density remain a bottleneck, due to the lack of the necessary equipments in ordinary laboratories. We describe here supersaturation-controlled microcrystallization and visualization and analysis tools that can be easily used in any laboratory. The microcrystallization conditions of the influenza virus hemagglutinin were initially obtained with low reproducibility, which was improved by employing a rapid evaporation of hanging drops. Supersaturation-controlled microcrystallization was then developed in a vapor diffusion mode, where supersaturation was induced by evaporation in hanging drops sequentially for durations ranging from 30 sec to 3 min, depending on the protein. It was applied successfully to the microcrystal formation of lysozyme, ferritin and hemagglutinin with high density. Moreover, visualization and analysis tools were developed to characterize the microcrystals observed by light microscopy. The size and density distributions of microcrystals analyzed by the tools were found to be consistent with the results of manual analysis, further validated by high-resolution microscopic analyses. Our supersaturation-controlled microcrystallization and visualization and analysis tools will provide universal access to successful XFEL studies.

15 April 2013 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
JCJoonsung Choi
Joonsung Choi
DKDongchan Kim
Dongchan Kim
COChang-Hyun Oh
Chang-Hyun Oh
YHYeji Han
Yeji Han
HPHyunWook Park
HyunWook Park
In MRI (magnetic resonance imaging), signal sampling along a radial k-space trajectory is preferred in certain applications due to its distinct advantages such as robustness to motion, and the radial sampling can be beneficial for reconstruction algorithms such as parallel MRI (pMRI) due to the incoherency. For radial MRI, the image is usually reconstructed from projection data using analytic methods such as filtered back-projection or Fourier reconstruction after gridding. However, the quality of the reconstructed image from these analytic methods can be degraded when the number of acquired projection views is insufficient. In this paper, we propose a novel reconstruction method based on the expectation maximization (EM) method, where the EM algorithm is remodeled for MRI so that complex images can be reconstructed. Then, to optimize the proposed method for radial pMRI, a reconstruction method that uses coil sensitivity information of multichannel RF coils is formulated. Experiment results from synthetic and in vivo data show that the proposed method introduces better reconstructed images than the analytic methods, even from highly subsampled data, and provides monotonic convergence properties compared to the conjugate gradient based reconstruction method.

1 January 2018 in Brazilian Journal of Medical and Biological Research
Verified
Journal Article
Open access
PDF file
JKJ.H. Kim
J.H. Kim
YSY.D. Son
Y.D. Son
JKJ.M. Kim
J.M. Kim
HKH.K. Kim
H.K. Kim
YKY.B. Kim
Y.B. Kim
COChang-Hyun Oh
Chang-Hyun Oh
Basal ganglia have complex functional connections with the cerebral cortex and are involved in motor control, executive functions of the forebrain, such as the planning of movement, and cognitive behaviors based on their connections. The aim of this study was to provide detailed functional correlation patterns between the basal ganglia and cerebral cortex by conducting an interregional correlation analysis of the 18F-fluorodeoxyglucose (18F-FDG) positron emission tomography (PET) data based on precise structural information. Fifteen participants were scanned with 7-Tesla magnetic resonance imaging (MRI) and high resolution research tomography (HRRT)-PET fusion system using 18F-FDG. For detailed interregional correlation analysis, 24 subregions of the basal ganglia including pre-commissural dorsal caudate, post-commissural caudate, pre-commissural dorsal putamen, post-commissural putamen, internal globus pallidus, and external globus pallidus and 80 cerebral regions were selected as regions of interest on the MRI image and their glucose metabolism were calculated from the PET images. Pearson's product-moment correlation analysis was conducted for the interregional correlation analysis of the basal ganglia. Functional correlation patterns between the basal ganglia and cerebral cortex were not only consistent with the findings of previous studies, but also showed new functional correlation between the dorsal striatum (i.e., caudate nucleus and putamen) and insula. In this study, we established the detailed basal ganglia subregional functional correlation patterns using 18F-FDG PET/MRI fusion imaging. Our methods and results could potentially be an important resource for investigating basal ganglia dysfunction as well as for conducting functional studies in the context of movement and psychiatric disorders.

1 January 2018 in Investigative Magnetic Resonance Imaging
Verified
Journal Article
Open access
PDF file
JKJong-Min Kim
Jong-Min Kim
CLChulhyun Lee
Chulhyun Lee
SHSeong-Dae Hong
Seong-Dae Hong
JKJeong-Hee Kim
Jeong-Hee Kim
KSKyung Sun
Kyung Sun
COChang-Hyun Oh
Chang-Hyun Oh
Kim JM, et al. Investig Magn Reson Imaging. 2018 Dec;22(4):218-228. https://doi.org/10.13104/imri.2018.22.4.218