Chengxi Zhu

Dr. Chengxi Zhu

orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 August 2021 in Journal of Imaging
Verified
Journal Article
Open access
PDF file
MSMary Stuart
Mary Stuart
Andrew McgonigleAndrew Mcgonigle
Andrew Mcgonigle
MDMatthew Davies
Matthew Davies
MHMatthew Hobbs
Matthew Hobbs
NBNicholas Boone
Nicholas Boone
JWJon Willlmott
Jon Willlmott
Recent advances in smartphone technologies have opened the door to the development of accessible, highly portable sensing tools capable of accurate and reliable data collection in a range of environmental settings. In this article, we introduce a low-cost smartphone-based hyperspectral imaging system that can convert a standard smartphone camera into a visible wavelength hyperspectral sensor for ca. £100. To the best of our knowledge, this represents the first smartphone capable of hyperspectral data collection without the need for extensive post processing. The Hyperspectral Smartphone’s abilities are tested in a variety of environmental applications and its capabilities directly compared to the laboratory-based analogue from our previous research, as well as the wider existing literature. The Hyperspectral Smartphone is capable of accurate, laboratory- and field-based hyperspectral data collection, demonstrating the significant promise of both this device and smartphone-based hyperspectral imaging as a whole.

14 January 2020 in Measurement Science and Technology
Verified
Journal Article
Open access
PDF file
CZChengxi Zhu
Chengxi Zhu
MHMatthew Hobbs
Matthew Hobbs
JWJon Willlmott
Jon Willlmott
Emissivity is a quantity essential to consider when assessing the measurement uncertainty in non-contact temperature measurements. This paper presents a new instrument for measuring emissivity of opaque materials from 200 °C to 450 °C in the spectral range of 2.1 to 2.5 µm. These ranges are ideal for measuring the temperature of metals, such as aluminium, during manufacture or heat-treating processes. The instrument consists of a pair of hemispherical cups coated with Vantablack® and gold respectively, a custom designed radiation thermometer, and a hot plate. This instrument enables both the direct and the indirect methods for measuring emissivity of materials. Use of two identical cups allowed for quantitative analysis of the uncertainty of the instrument to determine the most suitable emissivity measurement range. The expanded uncertainty of the instrument was lower than 0.058 (k = 2) over the entire measuring temperature range. Studies were undertaken using different materials with emissivities ranging from 0.06 to 1. These included aluminium alloy 6082, stainless steel 304, and HiE-Coat 840M paint. Relative uncertainty analysis indicated that the indirect method was more accurate for measuring low-emissivity materials, whereas the direct method was more suitable for all other materials. Our instrument, with experimentally determined measurement uncertainty, aims to offer accurate emissivity references for use in radiation thermometry applications.

1 November 2024 in Optica
Verified
Journal Article
Open access
BZBoya Zhang
Boya Zhang
SDSam Daly
Sam Daly
CZChengxi Zhu
Chengxi Zhu
MLMartin O. Lenz
Martin O. Lenz
LWLucien E. Weiss
Lucien E. Weiss
KOKevin Oholleran
Kevin Oholleran
3D single-molecule imaging reveals nanoscale structures in cell volumes but is limited by the need for spectrally distinct fluorophores. We address this limitation with vortex light field microscopy (VLFM), a 3D spectral single-molecule localization technique with 25 nm spatial and 3 nm spectral precision over a 4 µm depth of field. By modifying our previous single-molecule light field microscope with an azimuthally oriented prism array, we generated spectral disparity orthogonal to axial disparity, enabling simultaneous spatial and spectral localization on a single detector. We demonstrate VLFM with four-color 3D single-particle tracking and two-color 3D dSTORM imaging in fixed cells, successfully identifying dyes with spectral peaks just 15 nm apart. This shows VLFM’s potential for enhancing spatial biology workflows requiring highly multiplexed imaging.

10 September 2018 in Optics Express
Verified
Journal Article
Open access
PDF file
MHMatthew Hobbs
Matthew Hobbs
CZChengxi Zhu
Chengxi Zhu
MGMatthew P. Grainger
Matthew P. Grainger
CTChee Hing Tan
Chee Hing Tan
JWJon Willlmott
Jon Willlmott
Conventional thermal imaging cameras, based on focal-plane array (FPA) sensors, exhibit inherent problems: such as stray radiation, cross-talk and the calibration uncertainty of ensuring each pixel behaves as if it were an identical temperature sensor. Radiation thermometers can largely overcome these issues, comprising of only a single detector element that can be optimised and calibrated. Although the latter approach can provide excellent accuracy for single-point temperature measurement, it does not provide a temperature image of the target object. In this work, we present a micromechanical systems (MEMS) mirror and silicon (Si) avalanche photodiode (APD) based single-pixel camera, capable of producing quantitative thermal images at an operating wavelength of 1 µm. This work utilises a custom designed f-theta wide-angle lens and MEMS mirror, to scan +/− 30° in both x- and y-dimensions, without signal loss due to vignetting at any point in the field of view (FOV). Our single-pixel camera is shown to perform well, with 3 °C size-of-source effect (SSE) related temperature error and can measure below 700 °C whilst achieving ± 0.5 °C noise related measurement uncertainty. Our measurements were calibrated and traceable to the International Temperature Scale of 1990 (ITS-90). The combination of low SSE and absence of vignetting enables quantitative temperature measurements over a spatial field with measurement uncertainty at levels lower than would be possible with FPA based thermal imaging cameras.

30 September 2019 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Open access
CZChengxi Zhu
Chengxi Zhu
MHMatthew Hobbs
Matthew Hobbs
RMRobert C. Masters
Robert C. Masters
CRCornelia Rodenburg
Cornelia Rodenburg
JWJon Willlmott
Jon Willlmott
Emissivity is a material property that must be measured before an accurate non-contact temperature measurement can be made. We have developed a novel instrument for measuring apparent emissivity under a controlled atmosphere, providing data for applications in radiation thermometry. Our instrument employs a split furnace, a sample-blackbody component, two custom designed radiometers and a controlled atmospheric system. We measure across the temperature range from 973 to 1423 K and spectral range from 0.85 to 1.1 lm; this range is matched to the majority of high temperature radiation thermometers. The sample and reference approximate-blackbody are heated and maintained in thermal equilibrium, with a temperature difference of better than 1 K at 1423 K. The combined standard uncertainty of the system is lower than 0.0590 (at k=2) over the whole temperature range. Apparent emissivity of type 304 stainless steel (SS304) was studied under different oxidising procedures. Nitrogen and compressed air were input into the system to control the oxidisation process. We elucidated the relationship between the apparent emissivity variations and the surface composition changes of SS304 during oxidisation. Our study aims towards accurate and traceable apparent emissivity data, with well investigated uncertainty, for use in radiation thermometry.

13 December 2018 in Applied Optics
Verified
Journal Article
Open access
PDF file
CZChengxi Zhu
Chengxi Zhu
MHMatthew Hobbs
Matthew Hobbs
MGMatthew P. Grainger
Matthew P. Grainger
JWJon Willlmott
Jon Willlmott
We present a wide field of view (FOV) infrared scanning system, designed for single-pixel near-infrared thermal imaging. The scanning system consisted of a two-axis micro-electromechanical system (MEMS) mirror that was incorporated within the lens. The optical system consisted of two groups of lenses and a silicon avalanche photodiode. The system was designed for both the production of thermal images and also to utilize the techniques of radiation thermometry to measure the absolute temperature of targets from 500°C to 1100°C. Our system has the potential for real-time image acquisition, with improved data acquisition electronics. The FOV of our scanning system was ±30° when fully utilizing the MEMS mirror’s scanning angle of ±5°. The pixel FOV (calculated from the distance to target size ratio) was 100:1. The image quality was analyzed, including the modulation transfer function, spot diagrams, ray fan plots, lateral chromatic aberrations, distortion, relative illumination, and size-of-source effect. The instrument was fabricated in our laboratory, and one of the thermal images, which was taken with the new lens, is presented as an example of the instrument optical performance.