Ahmed Abdelghany

Prof. Ahmed Abdelghany

Minia University, Faculty of Medicine
orcid

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 August 2017 in Ophthalmology and Therapy
Verified
Journal Article
Open access
PDF file
JBJorge L. Alió del Barrio
Jorge L. Alió del Barrio
ARAlejandra E. Rodriguez
Alejandra E. Rodriguez
RFRenan Ferreira-Oliveira
Renan Ferreira-Oliveira
DWDominika Wróbel-Dudzińska
Dominika Wróbel-Dudzińska
Ahmed AbdelghanyAhmed Abdelghany
Ahmed Abdelghany
The objective of this study was to evaluate the use of autologous platelet-rich plasma (PRP) eye drops as monotherapy for the treatment of moderate to severe cases of dry eye disease.

14 October 2014 in Eye and Vision
Verified
Journal Article
Open access
PDF file
Ahmed AbdelghanyAhmed Abdelghany
Ahmed Abdelghany
JBJorge L. Alió del Barrio
Jorge L. Alió del Barrio
Refractive errors are frequently found following cataract surgery and refractive lens exchange. Accurate biometric analysis, selection and calculation of the adequate intraocular lens (IOL) and modern techniques for cataract surgery all contribute to achieving the goal of cataract surgery as a refractive procedure with no refractive error. However, in spite of all these advances, residual refractive error still occasionally occurs after cataract surgery and laser in situ keratomileusis (LASIK) can be considered the most accurate method for its correction. Lens-based procedures, such as IOL exchange or piggyback lens implantation are also possible alternatives especially in cases with extreme ametropia, corneal abnormalities, or in situations where excimer laser is unavailable. In our review, we have found that piggyback IOL is safer and more accurate than IOL exchange. Our aim is to provide a review of the recent literature regarding target refraction and residual refractive error in cataract surgery.

18 October 2015 in BioMed Research International
Verified
Journal Article
Open access
PDF file
JBJorge L. Alió del Barrio
Jorge L. Alió del Barrio
Ahmed AbdelghanyAhmed Abdelghany
Ahmed Abdelghany
RBRafael Barraquer
Rafael Barraquer
LHLaila M. Hammouda
Laila M. Hammouda
ASAhmed M. Sabry
Ahmed M. Sabry
The purpose of the study is to report the visual, refractive, and wound healing pattern outcomes of femtosecond assisted deep anterior lamellar keratoplasty (DALK) compared to the conventional manual technique. DALK was performed on 50 eyes of 47 advanced keratoconus patients. The patients were divided into two groups, 25 eyes each, depending on whether femtosecond assisted or manual DALK technique was performed for the side cut of the procedure only. Patients were followed up at 1 month, 6 months, and 1 year for visual acuity, clinical refraction, corneal cylinder, date of suture removal, and side cut corneal healing pattern according to new grading classification of the side cut scar (Grade 0 = transparent scar, 1 = faint healing opacity, 2 = evident healing opacity, 3 = significant opacity with some cosmetic imbalance, and 4 = highly significant opacity with very significant cosmetic imbalance). Outcomes are reported at one year. In conclusion, femtosecond assisted and manual DALK show comparable visual and refractive outcomes but femtosecond assisted DALK shows more evident corneal wound healing patterns at the side cut. This observation may indicate that an activated cornea wound healing might allow earlier suture removal when femtosecond technology is used to perform the side cut for DALK.

1 July 2014 in Current Opinion in Ophthalmology
Verified
Journal Article
Closed access
JAJorge L. Alio
Jorge L. Alio
Ahmed AbdelghanyAhmed Abdelghany
Ahmed Abdelghany
RFRoberto Fernández-Buenaga
Roberto Fernández-Buenaga
To provide a review of the recent literature on the management of residual refractive error after cataract surgery. Laser in-situ keratomileusis (LASIK) is the most accurate procedure to correct residual refractive error after cataract surgery. Lens-based procedures, such as intraocular lens (IOL) exchange or piggyback lens implantation, are also possible alternatives in cases with extreme ametropia, corneal abnormalities, or in situations where excimer laser is not available. In this review, we found that Piggyback IOL were safer and more accurate than IOL exchange. Emmetropia is our main target today in modern cataract surgery. Accurate biometric analysis, selection and calculation of the adequate IOL, and modern techniques for cataract surgery all help surgeons to move toward the goal of cataract surgery as a refractive procedure free from refractive error. However, in spite of all these inputs, residual refractive error still occasionally occurs after cataract surgery and LASIK seems to be the most accurate method for its correction.

12 December 2017 in Journal of Ophthalmology
Verified
Journal Article
Open access
PDF file
JBJorge L. Alió del Barrio
Jorge L. Alió del Barrio
ARAlejandra E. Rodriguez
Alejandra E. Rodriguez
Ahmed AbdelghanyAhmed Abdelghany
Ahmed Abdelghany
RORenan F. Oliveira
Renan F. Oliveira
Purpose. To evaluate the efficacy of autologous platelet-rich plasma (E-PRP) eye drops for the treatment of chronic ocular surface syndrome (OSS) following laser in situ keratomileusis (LASIK).Methods. This prospective interventional consecutive clinical study include 156 eyes of 80 patients affected by post-LASIK chronic OSS who were treated with autologous E-PRP 6 times a day as monotherapy for 6 weeks.Results. Dry eye symptoms improved in 85% of the cases. A decrease in at least one quadrant to total disappearance on CFS was observed in 89.6% of the patients who had positive CFS before treatment. Three eyes presented severe punctate keratitis (1.9%) at baseline, all of which healed completely. Conjunctival hyperemia improved in 93.3% of the patients with previous signs of ocular surface inflammation. There was a significant improvement in logMAR CDVA from 0.14 ± 0.19 to 0.06 ± 0.12 (p=0.000), and 74 (71.4%) eyes improved at least 1 line in CDVA.Conclusion. Monotherapy with autologous E-PRP is a well-tolerated, safe, and effective treatment for the management of post-LASIK ocular surface syndrome.Precis. Monotherapy with autologous platelet-rich plasma eye drops has been shown to be an adequate option for the treatment of post-LASIK chronic ocular surface syndrome. This trial is registered withNCT03322917.

1 November 2016 in Survey of Ophthalmology
Verified
Journal Article
Closed access
JBJorge L. Alió del Barrio
Jorge L. Alió del Barrio
Ahmed AbdelghanyAhmed Abdelghany
Ahmed Abdelghany
AAAhmed A Abdou
Ahmed A Abdou
MMM J Maldonado
M J Maldonado