10 min.). Uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), spherical equivalent (SE), simulated keratometry (Sim K-1, Sim K-2, K-max, K-mean), cylindrical (CYL), pachymetry and Q-value were evaluated preoperatively and for 3 years postoperatively

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 June 2014 in Journal of Refractive Surgery
Verified
Journal Article
Closed access
PDF file
JBJorge L. Alió del Barrio
Jorge L. Alió del Barrio
AAAhmed A. Abdou
Ahmed A. Abdou
APAlfonso Arias Puente
Alfonso Arias Puente
MZMiguel Angel Zato
Miguel Angel Zato
ZNZoltan Nagy
Zoltan Nagy
PURPOSE: To describe femtosecond laser cataract surgery and discuss the published peer-reviewed articles to have a fair evaluation of this new technology and its comparisons to conventional phacoemulsification surgery. METHODS: The technology information released in this article comes from the key individuals in each of the U.S. Food and Drug Administration-approved companies and from the available commercial information. Bibliographic research was performed in PubMed and MEDLINE for the published prospective or retrospective clinical studies. RESULTS: The femtosecond laser has been reported to be safe intraoperatively and postoperatively, with less cornea and macula effect than conventional phacoemulsification. The incision is integrated, stable, and aberration free. Many studies reported the high precision of the capsulotomy over manual continuous curvilinear capsulorhexis, which favors less intraocular lens tilt, higher optical quality, and more accurate premium intraocular lens centration. The lens fragmentation is effective with significant reduction of the phacoemulsification power and effective phacoemulsification time. The refractive difference between femtosecond laser and standard phacoemulsification is minimal, with no difference in corrected distance visual acuity, but the optical quality and the internal aberrations results are significantly better for femtosecond laser phacoemulsification. CONCLUSIONS: Femtosecond laser cataract surgery is a good addition to cataract surgery despite its few remarkable advantages among experienced phacoemulsification surgeons. [ J Refract Surg. 2014;30(6):420–427.]

1 September 2013 in Journal of Refractive Surgery
Verified
Journal Article
Closed access
PDF file
JBJorge L. Alió del Barrio
Jorge L. Alió del Barrio
AAAhmed A. Abdou
Ahmed A. Abdou
FSFelipe Soria
Felipe Soria
JJJaime Javaloy
Jaime Javaloy
RFRoberto Fernández-Buenaga
Roberto Fernández-Buenaga
TFTamás Filkorn
Tamás Filkorn
PURPOSE: Analysis of the femtosecond laser refractive lens surgery corneal incision configuration and corneal higher-order aberration (HOA) effect from the first postoperative day.METHODS: High-resolution anterior segment optical coherence tomography was used to assess 20 eyes undergoing femtosecond laser refractive lens surgery with 2.2-mm minimal incision. The primary incision (tri-planar) actual length, cord length, surface angle, surface irregularity, and regional pachymetry values and the secondary incision (uni-planar) length, angle, surface irregularity, and pachymetry values were analyzed. Hartmann-Shack aberrometer was used to assess corneal HOAs to correlate the effect. Assessment was done preoperatively and 1 month postoperatively.RESULTS: The actual length, cord length, and surface angle means for the primary incision in the first postoperative day and month were 1.50 ± 0.1 and 1.47 ± 0.2 mm (P= .5), 1.41 ± 0.1 and 1.42 ± 0.2 mm (P= .8), and 27° ± 4° and 23° ± 5° (P= .07), respectively. The length and surface angle for the secondary incision in the first postoperative day and month were 1.17 ± 0.01 and 1.04 ± 0.1 mm (P= .05) and 52° ± 3° and 42° ± 5° (P= .007). The regional pachymetry values for the primary and secondary incisions were significantly increased in the first postoperative day and then significantly decreased after 1 month. All irregularities occurred in the posterior surface (endothelium): 2 cases of posterior gap (first day) and 1 case of posterior retraction (first month). The HOAs had not significantly changed preoperatively and after 1 month.CONCLUSIONS: The femtosecond laser refractive lens surgery incision is stable and does not significantly change the HOA.[J Refract Surg.2013;29(9):590–595.]

1 November 2016 in Survey of Ophthalmology
Verified
Journal Article
Closed access
JBJorge L. Alió del Barrio
Jorge L. Alió del Barrio
Ahmed AbdelghanyAhmed Abdelghany
Ahmed Abdelghany
AAAhmed A Abdou
Ahmed A Abdou
MMM J Maldonado
M J Maldonado

1 November 2020 in Clinical Ophthalmology
Verified
Journal Article
Open access
PDF file
IAIbrahim Amer
Ibrahim Amer
AEAbdelhakeem Elaskary
Abdelhakeem Elaskary
AMAli Mostafa
Ali Mostafa
HHHazem A Hazem
Hazem A Hazem
AOAhmed Omar
Ahmed Omar
AAAhmed Abdou
Ahmed Abdou
Purpose: To compare the visual, refractive and topographic outcomes of standard and accelerated corneal collagen cross-linking (CXL) in pediatric keratoconus patients. Methods: Prospective, comparative observational study on 68 eyes of 35 pediatric keratoconus patients (< 18 years). Patients were classified into two groups, group (I) included 34 eyes and received standard “Epi-Off” CXL (3 mW/cm2, 30 min.) and group (II) included 34 eyes and received accelerated “Epi-Off” CXL (9 mW/cm2, 10 min.). Uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), spherical equivalent (SE), simulated keratometry (Sim K-1, Sim K-2, K-max, K-mean), cylindrical (CYL), pachymetry and Q-value were evaluated preoperatively and for 3 years postoperatively. Results: Postoperative UDVA and CDVA did not significantly change in both groups after 3 years. Postoperative SE was increased significantly in accelerated CXL (p=0.012) with no significant change in the postoperative cylinder in both procedures. Standard CXL had greater “significant” effect in decreasing Sim K-1, K-max and K-mean. The mean reduction in postoperative corneal pachymetry (at thinnest location) was significant in standard CXL (18.4 μm) (p=0.001). No significant change was noticed in postoperative Q-value. Conclusion: Standard and accelerated CXL protocols are efficient in pediatric keratoconus management with better outcomes in the standard procedure.

1 January 2016 in Journal of Refractive Surgery
Verified
Journal Article
Closed access
APAna B. Plaza-Puche
Ana B. Plaza-Puche
AAAmr El Aswad
Amr El Aswad
SASamuel Arba-Mosquera
Samuel Arba-Mosquera
DWDominika Wróbel-Dudzińska
Dominika Wróbel-Dudzińska
AAAhmed A. Abdou
Ahmed A. Abdou
JAJorge L. Alió
Jorge L. Alió
PURPOSE: To evaluate corneal higher order aberrations after LASIK for the correction of high hyperopia using a 500-Hz excimer laser and optimized ablation profile. METHODS: Retrospective consecutive study including 51 eyes of 28 patients (age range: 21 to 54 years) with high hyperopia or hyperopic astigmatism (sphere ≥ 5.00 diopters). All cases underwent LASIK using the sixth generation Amaris excimer laser (SCHWIND eye-tech-solutions, Kleinostheim, Germany) and a femtosecond laser platform for flap creation. Postoperative changes in corneal higher order aberrations for the 4-, 5-, and 6-mm pupil diameters and corneal asphericity for 4.5 and 8 mm were represented at the end of the 6-month follow-up. RESULTS: A significant increase in corneal root mean square higher order, spherical, and coma aberrations was observed 6 months after surgery ( P < .01). Corneal asphericity for the 4.5-mm (Q45) and 8-mm (Q8) corneal diameter also changed significantly during the postoperative period ( P < .01). Strehl ratio change was not statistically significant ( P = .77). CONCLUSIONS: Correction of high hyperopia with LASIK significantly induces corneal higher order aberrations regardless of the physiologic level of photopic and mesopic pupil conditions. [ J Refract Surg. 2016(1);6–13.]

1 January 2014 in Current Opinion in Ophthalmology
Verified
Journal Article
Closed access
JAJorge L. Alio
Jorge L. Alio
FSFelipe Soria
Felipe Soria
AAAhmed A. Abdou
Ahmed A. Abdou
This review outlines the advantages and the differences of femtosecond laser-assisted cataract surgery (FLACS) following a coaxial or microincision cataract surgery phacoemulsification in the surgical outcome and greater control of cataract surgery. FLACS offers minimal tissue damage and extreme precision during corneal incision creation, continuous circular capsulorhexis (CCC) and nuclear fragmentation. It also allows diminishing the mean average ultrasound power to emulsify the nucleus followed by a coaxial or a biaxial procedure. The impact of reduced phacoemulsification energy on the corneal endothelium is an interesting topic that is being investigated. Despite its benefits, this technology has relevant financial issues and a high learning curve. FemtoMICS appears to be surgically and statistically more efficient than the FemtoCoaxial technique and Femtoincisions prove to be stable and do not change the corneal high order aberration significantly with favorable results of the triplanar configuration.