Jaume Francisco-Pascual

Dr. Jaume Francisco-Pascual

orcid

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 August 2018 in JACC: Cardiovascular Interventions
Verified
Journal Article
Closed access
JRJosep Rodés-Cabau
Josep Rodés-Cabau
MUMarina Urena
Marina Urena
LNLuis Nombela-Franco
Luis Nombela-Franco
IAIgnacio Amat-Santos
Ignacio Amat-Santos
NKNeal Kleiman
Neal Kleiman
FPFrançois Philippon
François Philippon

3 February 2015 in Circulation
Verified
Journal Article
Closed access
MUMarina Urena
Marina Urena
SHSalim Hayek
Salim Hayek
ACAsim N. Cheema
Asim N. Cheema
VSVicenç Serra
Vicenç Serra
IAIgnacio J. Amat-Santos
Ignacio J. Amat-Santos
JRJosep Rodés-Cabau
Josep Rodés-Cabau
Background—: This study sought to evaluate the prevalence of previously undiagnosed arrhythmias in candidates for transcatheter aortic valve replacement (TAVR) and to determine the impact on therapy changes and arrhythmic events after the procedure. Methods and Results—: A total of 435 candidates for TAVR underwent 24-hour continuous ECG monitoring the day before the procedure. Newly diagnosed arrhythmias were observed in 70 patients (16.1%) before TAVR: paroxysmal atrial fibrillation (AF)/atrial tachycardia (AT) in 28, advanced atrioventricular block or severe bradycardia in 24, nonsustained ventricular tachycardia in 26, and intermittent left bundle-branch block in 3 patients. All arrhythmic events but one were asymptomatic and led to a therapy change in 43% of patients. In patients without known AF/AT, the occurrence of AF/AT during 24-hour ECG recording was associated with a higher rate of 30-day cerebrovascular events (7.1% versus 0.4%; P =0.030). Among the 53 patients with new-onset AF/AT after TAVR, 30.2% had newly diagnosed paroxysmal AF/AT before the procedure. In patients who needed permanent pacemaker implantation after the procedure (n=35), 31.4% had newly diagnosed advanced atrioventricular block or severe bradycardia before TAVR. New-onset persistent left bundle-branch block after TAVR occurred in 37 patients, 8.1% of whom had intermittent left bundle-branch block before the procedure. Conclusions—: Newly diagnosed arrhythmias were observed in approximately a fifth of TAVR candidates, led to a higher rate of cerebrovascular events, and accounted for a third of arrhythmic events after the procedure. This high arrhythmia burden highlights the importance of an early diagnosis of arrhythmic events in such patients to implement the appropriate therapeutic measures earlier.

1 January 2018 in International Journal of Cardiology
Verified
Journal Article
Closed access
JPJorge Pagola
Jorge Pagola
JJJesus Juega
Jesus Juega
JFJaume Francisco-Pascual
Jaume Francisco-Pascual
AMAngel Moya
Angel Moya
MSMireia Sanchis
Mireia Sanchis
AEArturo Evangelista
Arturo Evangelista

1 January 2016 in Thrombosis and Haemostasis
Verified
Journal Article
Closed access
PDF file
BBBruno García Del Blanco
Bruno García Del Blanco
MRMarisol Ruiz-Meana
Marisol Ruiz-Meana
JFJaume Francisco-Pascual
Jaume Francisco-Pascual
José BarrabésJosé Barrabés
José Barrabés
JFJaume Figueras
Jaume Figueras
ASAntonia Sambola
Antonia Sambola
Therapeutic fibrinolysis is ineffective in 40 % of ST-segment elevation acute myocardial infarction (STEMI) patients, but understanding of the mechanisms is incomplete. It was our aim to compare the composition of coronary thrombus in lysis-resistant STEMI patients with that of lysis-sensitive patients. Intracoronary thrombi (n=64) were obtained by aspiration in consecutive STEMI patients. Of them, 20 had received fibrinolysis and underwent rescue percutaneous coronary intervention (r-PCI, lysis-resistant patients) and 44 underwent primary PCI (p-PCI). Lysis-sensitivity was determined in vitro by clot permeability measurements and turbidimetric lysis in plasma of 44 patients undergoing p-PCI and 20 healthy donors. Clot-lysis sensitivity was defined as a clot-lysis time not greater than 1 SD over the mean of healthy donors. Coronary thrombus composition in 20 lysis-resistant and in 20 lysissensitive patients was analysed by immunofluorescence with confocal microscopy. Plasma biomarkers (P-selectin, VWF, PAI-1, t-PA, D-dimer, TF pathway markers, plasmin and CD34+) were measured simultaneously on peripheral blood. Lysis-resistant clots had higher levels of fibrin (p=0.02), P-selectin (p=0.03) and VWF (p=0.01) than lysis-sensitive clots. Among thrombi obtained ≤ 6 hours after onset of symptoms, those from lysis-resistant patients showed a higher content in fibrin than those from p-PCI patients (p=0.01). Plasma PAI-1 (p=0.02) and D-dimer levels were significantly higher (p=0.003) in lysis-resistant patients, whereas plasmin levels were lower (p=0.03). Multivariate analysis showed the content of fibrin and VWF within thrombus as predictors of thrombolysis resistance. In conclusion, coronary thrombi in STEMI patients resistant to fibrinolysis are characterised by higher fibrin, P-selectin and VWF content than lysis-sensitive thrombi.

29 April 2020 in European Journal of Neurology
Verified
Journal Article
Closed access
PDF file
JPJorge Pagola
Jorge Pagola
JJJesus Juega
Jesus Juega
JFJaume Francisco-Pascual
Jaume Francisco-Pascual
ABAlejandro Bustamante
Alejandro Bustamante
APAnna Penalba
Anna Penalba
TGthe Crypto‐AF study group
the Crypto‐AF study group

1 June 2018 in JACC: Clinical Electrophysiology
Verified
Journal Article
Closed access
IRIvo Roca-Luque
Ivo Roca-Luque
NRNuria Rivas-Gándara
Nuria Rivas-Gándara
LSLaura Dos Subirà
Laura Dos Subirà
JFJaume Francisco-Pascual
Jaume Francisco-Pascual
APAntònia Pijuan-Domenech
Antònia Pijuan-Domenech
AMAngel Moya Mitjans
Angel Moya Mitjans