Kishore Ranganath Ramakrishnan

Dr. Kishore Ranganath Ramakrishnan

orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 December 2019 in Journal of Thermal Science and Engineering Applications
Verified
Journal Article
Closed access
PDF file
SMSrivatsan Madhavan
Srivatsan Madhavan
KRKishore Ranganath Ramakrishnan
Kishore Ranganath Ramakrishnan
PSPrashant Singh
Prashant Singh
SESrinath Ekkad
Srinath Ekkad
Array jet impingement is typically used in gas turbine blade near-wall cooling, where high rates of heat dissipation is required. The accumulated crossflow massflux results in significant reduction in jet effectiveness in the downstream rows, leading to reduced cooling performance. In this paper, a jet impingement system equipped with U-shaped ribs (hereafter referred as ‘diverter’) were used for diverting the crossflow away from the jets emanating from the nozzle plate. To this end, a baseline configuration of array jet impingement onto smooth target surface is considered, where the normalized jet-to-jet spacing (x/dj = y/dj) was 6 and the normalized jet-to-target spacing (z/dj) was 2. Crossflow diverters with thickness ‘t’ of 1.5875 mm and height ‘h’ of 2dj (= z) were installed at a distance of 2dj from the respective jet centers. Detailed heat transfer coefficients have been calculated through transient liquid crystal experiments carried out over Reynolds numbers ranging from 3500 to 12000. It has been observed that crossflow diverters protect the downstream jets from upstream jet deflection thereby maximizing their stagnation cooling potential. An average of 15-30% enhancement in Nusselt number is obtained over the flow range tested. This benefit in heat transfer came at a cost of increased pumping power to maintain similar flow rate in the system. At a given pumping power, crossflow diverters yielded an enhancement of 9 – 15% in heat transfer compared to the baseline case.

10 February 2022 in Journal of Heat Transfer
Verified
Journal Article
Closed access
PDF file
PBPratik S. Bhansali
Pratik S. Bhansali
KRKishore Ranganath Ramakrishnan
Kishore Ranganath Ramakrishnan
SESrinath Ekkad
Srinath Ekkad

18 June 2021 in Journal of Thermal Science and Engineering Applications
Verified
Journal Article
Closed access
PDF file
SAShoaib Ahmed
Shoaib Ahmed
KRKishore Ranganath Ramakrishnan
Kishore Ranganath Ramakrishnan
SESrinath Ekkad
Srinath Ekkad
Emphasis on lean premixed combustion in modern low NOX combustion chambers limits the air available for cooling the combustion liner. Hence, the development of optimized liner cooling designs is imperative for effective usage of available coolant. An effective way to cool a gas turbine combustor liner is through effusion cooling. Effusion cooling (also known as full-coverage film cooling) involves uniformly spaced holes distributed throughout the liner’s curved surface area. This study presents findings from an experimental study on the characterization of the overall cooling effectiveness of an effusion-cooled liner wall, which was representative of a can combustor under heated flow (non-reacting) and lean-combustion (reacting) conditions. The model can combustor was equipped with an industrial swirler, which subjected the liner walls to engine representative flow and combustion conditions. In this study, two different effusion cooling liners with an inline and staggered arrangement of effusion holes have been studied. Non-dimensionalized streamwise hole-to-hole spacing (z/d) and spanwise hole-to-hole spacing (r/d) of 10 were used for both the effusion liners. These configurations were tested for five different blowing ratios ranging from 0.7 to 4.0 under both reacting and non-reacting conditions. The experiments were carried out at a constant main flow Reynolds number (based on combustor diameter) of 12,500. The non-reacting experiments were carried out by heating the mainstream air, and the reacting experiments were carried out under flame conditions at a total equivalence ratio of 0.65. Infrared thermography (IRT) was used to measure the liner outer surface temperature, and detailed overall effectiveness values were determined under steady-state conditions. It was observed that overall cooling effectiveness trends were different under reacting and non-reacting conditions. The cooling effectiveness for the non-reacting experiments exhibited a decreasing trend, and no consistent location of minimum cooling effectiveness was observed for the range of blowing ratios investigated in this study. For the reacting cases, the cooling effectiveness first follows a decreasing trend, reaches a distinct minimum, and then increases till the end of the combustor. Under non-reacting conditions, the staggered configuration was 9–25% more effective than inline configuration, and under reacting conditions, the staggered configuration was 4–8% more effective than inline configuration. From this study, it is clear that the coolant flame interaction for the reacting experiments impacted the liner cooling effectiveness and led to different overall cooling effectiveness distribution on the liner when compared with the non-reacting experiments.

22 June 2021 in Journal of Thermal Science and Engineering Applications
Verified
Journal Article
Closed access
PDF file
KRKishore Ranganath Ramakrishnan
Kishore Ranganath Ramakrishnan
SAShoaib Ahmed
Shoaib Ahmed
SESrinath Ekkad
Srinath Ekkad
As stringent emissions controls are being placed on gas turbines, modern combustor design optimization is contingent on the accurate characterization of the combustor flame side heat loads. Power generation turbines are increasingly moving toward natural gas, biogas, and syngas, whose composition is highly dependent on the sourcing location. With fuel flexible nozzles, it is important to understand the heat load from various gas mixtures to optimize the cooling design to make sure the liner is not under/over cooled for some mixtures as this has a larger effect on NOx/CO emissions. In addition to knowing the heat load distribution, it is important to understand the peak heat load under start/stop transient conditions which tend to be much higher than steady-state/cruise altitude heat loads. The present work focuses on the experimental measurement of the transient heat load along a can combustor under reacting conditions for a swirl-stabilized premixed methane–air flame. Tests were carried out under various equivalence ratios, Reynolds numbers, and pilot fuel flowrate. An infrared camera was used to measure the inner and outer wall temperatures of the liner to calculate the liner heat load. Particle image velocimetry (PIV) was employed to visualize the flowfield for various reacting conditions studied in this work. Based on the heat transfer study, a detailed report of transient heat load along the length of the liner wall has been presented here. Initial start transient heat load on the liner wall is ∼10–40% more than the steady-state heat load.

15 March 2017 in Journal of Thermal Science and Engineering Applications
Verified
Journal Article
Closed access
PDF file
HBHari Subramaniam Bhaskaran
Hari Subramaniam Bhaskaran
PRPaul I. Ro
Paul I. Ro
JPJoong-Kyoo Park
Joong-Kyoo Park
KRKishore Ranganath Ramakrishnan
Kishore Ranganath Ramakrishnan
This paper analyses a novel heat transfer enhancement technique that can be used in compressors to limit the temperature rise during compression. This technique is based on the injection of external high-pressure gas into the chamber during the compression process. The impact of different factors on the effectiveness of this technique has been studied using experimental and computational methods. In the first set of trials, the location and angle of injection of the external air was varied. It was observed that the heat transfer coefficient governing the heat transfer rate from the chamber varied greatly with change in location and angle of injection. In the second set of experiments, the source pressure of the injected gas was varied from 100.66 kPa to 551.58 kPa. It was observed that the temperature rise of air in the chamber was reduced with an increase in source pressure. Additionally, the increase in chamber pressure was steeper in the higher source pressure cases. In the third set of experiments, the injection profile of the injected gas was varied. This parameter did not greatly impact the effectiveness of external gas injection. In the last set of experiments, the time of initiation of injection was varied. Earlier injection had a positive impact on reducing the temperature rise in the chamber. However, the pressure in the chamber was seen to increase more rapidly in the runs with early injection. Considering that these factors could have a positive/negative impact on the temperature and pressure in the chamber (work required for compression), it may be required to optimize the injection of external high-pressure gas depending on the application.

16 July 2021
Verified
Preprint
Open access
KRKishore Ranganath Ramakrishnan
Kishore Ranganath Ramakrishnan
SAShoaib Ahmed
Shoaib Ahmed
SESrinath Ekkad
Srinath Ekkad
FLFederico Liberatore
Federico Liberatore
YHYin-Hsiang Ho
Yin-Hsiang Ho
Modern combustor design optimization is contingent on the accurate characterization of the combustor flame side heat loads. Knowledge of regions of high and low heat loads on the liner wall helps designers optimize the cooling designs. The present work focuses on the experimental measurement of the transient heat load along a fused silica (quartz) optical can combustor under