Felix Corr

Mr. Felix Corr

orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 September 2022 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
Miriam H. A. BoppMiriam H. A. Bopp
Miriam H. A. Bopp
BSBenjamin Saß
Benjamin Saß
Mirza PojskicMirza Pojskic
Mirza Pojskic
FCFelix Corr
Felix Corr
DGDustin Grimm
Dustin Grimm
Christopher NimskyChristopher Nimsky
Christopher Nimsky
The aim of this study was to report on the clinical experience with microscope-based augmented reality (AR) in transsphenoidal surgery compared to the classical microscope-based approach. AR support was established using the head-up displays of the operating microscope, with navigation based on fiducial-/surface- or automatic intraoperative computed tomography (iCT)-based registration. In a consecutive single surgeon series of 165 transsphenoidal procedures, 81 patients underwent surgery without AR support and 84 patients underwent surgery with AR support. AR was integrated straightforwardly within the workflow. ICT-based registration increased AR accuracy significantly (target registration error, TRE, 0.76 ± 0.33 mm) compared to the landmark-based approach (TRE 1.85 ± 1.02 mm). The application of low-dose iCT protocols led to a significant reduction in applied effective dosage being comparable to a single chest radiograph. No major vascular or neurological complications occurred. No difference in surgical time was seen, time to set-up patient registration prolonged intraoperative preparation time on average by twelve minutes (32.33 ± 13.35 vs. 44.13 ± 13.67 min), but seems justifiable by the fact that AR greatly and reliably facilitated surgical orientation and increased surgeon comfort and patient safety, not only in patients who had previous transsphenoidal surgery but also in cases with anatomical variants. Automatic intraoperative imaging-based registration is recommended.

Verified
Journal Article
Open access
PDF file
FCFelix Corr
Felix Corr
DGDustin Grimm
Dustin Grimm
BSBenjamin Saß
Benjamin Saß
Mirza PojskicMirza Pojskic
Mirza Pojskic
Jörg Walter BartschJörg Walter Bartsch
Jörg Walter Bartsch
Miriam H. A. BoppMiriam H. A. Bopp
Miriam H. A. Bopp
Glioblastoma, as the most aggressive brain tumor, is associated with a poor prognosis and outcome. To optimize prognosis and clinical therapy decisions, there is an urgent need to stratify patients with increased risk for recurrent tumors and low therapeutic success to optimize individual treatment. Radiogenomics establishes a link between radiological and pathological information. This review provides a state-of-the-art picture illustrating the latest developments in the use of radiogenomic markers regarding prognosis and their potential for monitoring recurrence. Databases PubMed, Google Scholar, and Cochrane Library were searched. Inclusion criteria were defined as diagnosis of glioblastoma with histopathological and radiological follow-up. Out of 321 reviewed articles, 43 articles met these inclusion criteria. Included studies were analyzed for the frequency of radiological and molecular tumor markers whereby radiogenomic associations were analyzed. Six main associations were described: radiogenomic prognosis, MGMT status, IDH, EGFR status, molecular subgroups, and tumor location. Prospective studies analyzing prognostic features of glioblastoma together with radiological features are lacking. By reviewing the progress in the development of radiogenomic markers, we provide insights into the potential efficacy of such an approach for clinical routine use eventually enabling early identification of glioblastoma recurrence and therefore supporting a further personalized monitoring and treatment strategy.

23 July 2024 in Bioengineering
Verified
Journal Article
Open access
PDF file
Ziyu QiZiyu Qi
Ziyu Qi
FCFelix Corr
Felix Corr
DGDustin Grimm
Dustin Grimm
Christopher NimskyChristopher Nimsky
Christopher Nimsky
Miriam H. A. BoppMiriam H. A. Bopp
Miriam H. A. Bopp
Surgical education demands extensive knowledge and skill acquisition within limited time frames, often limited by reduced training opportunities and high-pressure environments. This review evaluates the effectiveness of extended reality-based head-mounted display (ExR-HMD) technology in surgical education, examining its impact on educational outcomes and exploring its strengths and limitations. Data from PubMed, Cochrane Library, Web of Science, ScienceDirect, Scopus, ACM Digital Library, IEEE Xplore, WorldCat, and Google Scholar (Year: 2014–2024) were synthesized. After screening, 32 studies comparing ExR-HMD and traditional surgical training methods for medical students or residents were identified. Quality and bias were assessed using the Medical Education Research Study Quality Instrument, Newcastle–Ottawa Scale-Education, and Cochrane Risk of Bias Tools. Results indicate that ExR-HMD offers benefits such as increased immersion, spatial awareness, and interaction and supports motor skill acquisition theory and constructivist educational theories. However, challenges such as system fidelity, operational inconvenience, and physical discomfort were noted. Nearly half the studies reported outcomes comparable or superior to traditional methods, emphasizing the importance of social interaction. Limitations include study heterogeneity and English-only publications. ExR-HMD shows promise but needs educational theory integration and social interaction. Future research should address technical and economic barriers to global accessibility.
1

7 December 2022 in Sensors
Verified
Journal Article
Open access
PDF file
Miriam H. A. BoppMiriam H. A. Bopp
Miriam H. A. Bopp
FCFelix Corr
Felix Corr
BSBenjamin Saß
Benjamin Saß
Mirza PojskicMirza Pojskic
Mirza Pojskic
AKAndré Kemmling
André Kemmling
Christopher NimskyChristopher Nimsky
Christopher Nimsky
This study aims to report on the capability of microscope-based augmented reality (AR) to evaluate registration and navigation accuracy with extracranial and intracranial landmarks and to elaborate on its opportunities and obstacles in compensation for navigation inaccuracies. In a consecutive single surgeon series of 293 patients, automatic intraoperative computed tomography-based registration was performed delivering a high initial registration accuracy with a mean target registration error of 0.84 ± 0.36 mm. Navigation accuracy is evaluated by overlaying a maximum intensity projection or pre-segmented object outlines within the recent focal plane onto the in situ patient anatomy and compensated for by translational and/or rotational in-plane transformations. Using bony landmarks (85 cases), there was two cases where a mismatch was seen. Cortical vascular structures (242 cases) showed a mismatch in 43 cases and cortex representations (40 cases) revealed two inaccurate cases. In all cases, with detected misalignment, a successful spatial compensation was performed (mean correction: bone (6.27 ± 7.31 mm), vascular (3.00 ± 1.93 mm, 0.38° ± 1.06°), and cortex (5.31 ± 1.57 mm, 1.75° ± 2.47°)) increasing navigation accuracy. AR support allows for intermediate and straightforward monitoring of accuracy, enables compensation of spatial misalignments, and thereby provides additional safety by increasing overall accuracy.

13 September 2023 in World Neurosurgery
Verified
Journal Article
Closed access
FCFelix Corr
Felix Corr
FKFatma Kilinç
Fatma Kilinç
JOJan Oros
Jan Oros
LQLina-Elisabeth Qasem
Lina-Elisabeth Qasem
AAAli Al-Hilou
Ali Al-Hilou
JQJohanna Quick-Weller
Johanna Quick-Weller

Verified
Journal Article
Open access
PDF file
FCFelix Corr
Felix Corr
YAYasser F Almealawy
Yasser F Almealawy
SHSilvio Achim Heinig
Silvio Achim Heinig
LBLinda Bättig
Linda Bättig
ESErik Schulz
Erik Schulz
SMStefan Motov
Stefan Motov
Background/Objectives: Retained epidural catheter fragments are an infrequent but clinically relevant complication of neuraxial anesthesia. Optimal management remains undefined, with limited evidence guiding treatment selection or risk stratification. This systematic review synthesized individual patient data to compare treatment strategies, examine surgical outcomes, and determine predictors of intervention. Methods: A systematic review was conducted across six databases in accordance with PRISMA guidelines (PROSPERO: CRD420025638305). Adult cases of retained epidural catheter fragments were included. Functional outcomes were standardized using modified MacNab, McCormick, and Therapy–Disability–Neurology (TDN) scores. Predictors of surgery and detectability were assessed using univariate and multivariate logistic regression models with Firth correction. Results: Forty studies comprising 51 patients were included. Conservative management was chosen in 23 cases (45%); 39.1% (n = 9) ultimately required delayed surgery due to symptom onset during follow-up. Surgical removal (n = 28, 55%) was safe and yielded excellent outcomes in 95.8% of cases. Fragment length was significantly associated with increased odds of surgery (OR = 1.05, 95% CI: 1.01–1.10, p = 0.04), while catheter material was associated with surgery in univariate analysis (OR = 2.49, 95% CI: 1.08–9.00, p = 0.03). An MRI demonstrated the highest diagnostic accuracy (AUC = 0.859, cutoff = 70 mm catheter length), outperforming CT (AUC = 0.611) and X-ray (AUC = 0.533). Across all patients, 84.3% achieved “Excellent” recovery per MacNab, with no neurological deterioration in any surgical case. Conclusions: Surgical removal of retained epidural catheter fragments is safe and effective in symptomatic patients. Conservative management is viable for asymptomatic cases under structured surveillance. Catheter material and fragment length may dictate imaging selection and treatment decisions.