Ziyu Qi

Dr. Ziyu Qi

NEUROSURGERY, Universitätsklinikum Gießen und Marburg, Gießen, Hesse, Germany
+1
orcid
给白傻子买瓜子去!

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 August 2021 in Neurosurgical Focus
Verified
Journal Article
Closed access
PDF file
Ziyu QiZiyu Qi
Ziyu Qi
YLYe Li
Ye Li
XXXinghua Xu
Xinghua Xu
JZJiashu Zhang
Jiashu Zhang
FLFangye Li
Fangye Li
XCXiaolei Chen
Xiaolei Chen
OBJECTIVE: The authors aimed to evaluate the technical feasibility of a mixed-reality neuronavigation (MRN) system with a wearable head-mounted device (HMD) and to determine its clinical application and accuracy. METHODS: A semiautomatic registration MRN system on HoloLens smart glasses was developed and tested for accuracy and feasibility. Thirty-seven patients with intracranial lesions were prospectively identified. For each patient, multimodal imaging–based holograms of lesions, markers, and surrounding eloquent structures were created and then imported to the MRN HMD. After a point-based registration, the holograms were projected onto the patient's head and observed through the HMD. The contour of the holograms was compared with standard neuronavigation (SN). The projection of the lesion boundaries perceived by the neurosurgeon on the patient's scalp was then marked with MRN and SN. The distance between the two contours generated by MRN and SN was measured so that the accuracy of MRN could be assessed. RESULTS: MRN localization was achieved in all patients. The mean additional time required for MRN was 36.3 ± 6.3 minutes, in which the mean registration time was 2.6 ± 0.9 minutes. A trend toward a shorter time required for preparation was observed with the increase of neurosurgeon experience with the MRN system. The overall median deviation was 4.1 mm (IQR 3.0 mm–4.7 mm), and 81.1% of the lesions localized by MRN were found to be highly consistent with SN (deviation < 5.0 mm). There was a significant difference between the supine position and the prone position (3.7 ± 1.1 mm vs 5.4 ± 0.9 mm, p = 0.001). The magnitudes of deviation vectors did not correlate with lesion volume (p = 0.126) or depth (p = 0.128). There was no significant difference in additional operating time between different operators (37.4 ± 4.8 minutes vs 34.6 ± 4.8 minutes, p = 0.237) or in localization deviation (3.7 ± 1.0 mm vs 4.6 ± 1.5 mm, p = 0.070). CONCLUSIONS: This study provided a complete set of a clinically applicable workflow on an easy-to-use MRN system using a wearable HMD, and has shown its technical feasibility and accuracy. Further development is required to improve the accuracy and clinical efficacy of this system.

1 April 2021 in Quantitative Imaging in Medicine and Surgery
Verified
Journal Article
Open access
PDF file
YZYing Zou
Ying Zou
MZMeizhu Zheng
Meizhu Zheng
Ziyu QiZiyu Qi
Ziyu Qi
YGYu Guo
Yu Guo
XJXiaodong Ji
Xiaodong Ji
SXShuang Xia
Shuang Xia
Background: Dual-energy computed tomography (DECT) has been widely applied to detect lymph node (LN) and lymph node metastasis (LNM) in various cancers, including papillary thyroid carcinoma (PTC). This study aimed to quantitatively evaluate metastatic cervical lymph nodes (LNs) <0.5 cm in patients with PTC using DECT, which has not been done in previous studies. Methods: Preoperative DECT data of patients with pathologically confirmed PTC were retrospectively collected and analyzed between May 2016 and June 2018. A total of 359 LNs from 52 patients were included. Diameter, iodine concentration (IC), normalized iodine concentration (NIC), and the slope of the energy spectrum curve (λHU) of LNs in the arterial and the venous phases were compared between metastatic and non-metastatic LNs. The optimal parameters were obtained from the receiver operating characteristic (ROC) curves. The generalized estimation equation (GEE) model was used to evaluate independent diagnostic factors for LNM. Results: A total of 139 metastatic and 220 non-metastatic LNs were analyzed. There were statistical differences of quantitative parameters between the two groups (P value 0.000–0.007). The optimal parameter for diagnosing LNM was IC in the arterial phase, and its area under the curve (AUC), sensitivity, and specificity were 0.775, 71.9%, and 73.6%, respectively. When the three parameters of diameter, IC in the arterial phase, and NIC in the venous phase were combined, the prediction efficiency was better, and the AUC was 0.819. The GEE results showed that LNs located in level VIa [odds ratio (OR) 2.030, 95% confidence interval (CI): 1.134–3.634, P=0.017], VIb (OR 2.836, 95% CI: 1.597–5.038, P=0.000), diameter (OR 2.023, 95% CI: 1.158–3.532, P=0.013), IC in the arterial phase (OR 4.444, 95% CI: 2.808–7.035, P=0.000), and IC in the venous phase (OR 5.387, 95% CI: 3.449–8.413, P=0.000) were independent risk factors for LNM in patients with PTC. Conclusions: DECT had good diagnostic performance in the differentiation of cervical metastatic LNs <0.5 cm in patients with PTC.

23 July 2024 in Bioengineering
Verified
Journal Article
Open access
PDF file
Ziyu QiZiyu Qi
Ziyu Qi
FCFelix Corr
Felix Corr
DGDustin Grimm
Dustin Grimm
Christopher NimskyChristopher Nimsky
Christopher Nimsky
Miriam H. A. BoppMiriam H. A. Bopp
Miriam H. A. Bopp
Surgical education demands extensive knowledge and skill acquisition within limited time frames, often limited by reduced training opportunities and high-pressure environments. This review evaluates the effectiveness of extended reality-based head-mounted display (ExR-HMD) technology in surgical education, examining its impact on educational outcomes and exploring its strengths and limitations. Data from PubMed, Cochrane Library, Web of Science, ScienceDirect, Scopus, ACM Digital Library, IEEE Xplore, WorldCat, and Google Scholar (Year: 2014–2024) were synthesized. After screening, 32 studies comparing ExR-HMD and traditional surgical training methods for medical students or residents were identified. Quality and bias were assessed using the Medical Education Research Study Quality Instrument, Newcastle–Ottawa Scale-Education, and Cochrane Risk of Bias Tools. Results indicate that ExR-HMD offers benefits such as increased immersion, spatial awareness, and interaction and supports motor skill acquisition theory and constructivist educational theories. However, challenges such as system fidelity, operational inconvenience, and physical discomfort were noted. Nearly half the studies reported outcomes comparable or superior to traditional methods, emphasizing the importance of social interaction. Limitations include study heterogeneity and English-only publications. ExR-HMD shows promise but needs educational theory integration and social interaction. Future research should address technical and economic barriers to global accessibility.
1

30 January 2024 in Sensors
Verified
Journal Article
Open access
PDF file
Ziyu QiZiyu Qi
Ziyu Qi
HJHaitao Jin
Haitao Jin
QWQun Wang
Qun Wang
ZGZhichao Gan
Zhichao Gan
RXRuochu Xiong
Ruochu Xiong
Miriam H. A. BoppMiriam H. A. Bopp
Miriam H. A. Bopp
Addressing conventional neurosurgical navigation systems’ high costs and complexity, this study explores the feasibility and accuracy of a simplified, cost-effective mixed reality navigation (MRN) system based on a laser crosshair simulator (LCS). A new automatic registration method was developed, featuring coplanar laser emitters and a recognizable target pattern. The workflow was integrated into Microsoft’s HoloLens-2 for practical application. The study assessed the system’s precision by utilizing life-sized 3D-printed head phantoms based on computed tomography (CT) or magnetic resonance imaging (MRI) data from 19 patients (female/male: 7/12, average age: 54.4 ± 18.5 years) with intracranial lesions. Six to seven CT/MRI-visible scalp markers were used as reference points per case. The LCS-MRN’s accuracy was evaluated through landmark-based and lesion-based analyses, using metrics such as target registration error (TRE) and Dice similarity coefficient (DSC). The system demonstrated immersive capabilities for observing intracranial structures across all cases. Analysis of 124 landmarks showed a TRE of 3.0 ± 0.5 mm, consistent across various surgical positions. The DSC of 0.83 ± 0.12 correlated significantly with lesion volume (Spearman rho = 0.813, p < 0.001). Therefore, the LCS-MRN system is a viable tool for neurosurgical planning, highlighting its low user dependency, cost-efficiency, and accuracy, with prospects for future clinical application enhancements.
1

7 November 2023 in Bioengineering
Verified
Journal Article
Open access
PDF file
Ziyu QiZiyu Qi
Ziyu Qi
Miriam H. A. BoppMiriam H. A. Bopp
Miriam H. A. Bopp
Christopher NimskyChristopher Nimsky
Christopher Nimsky
XCXiaolei Chen
Xiaolei Chen
XXXinghua Xu
Xinghua Xu
JZJiashu Zhang
Jiashu Zhang
Mixed Reality Navigation (MRN) is pivotal in augmented reality-assisted intelligent neurosurgical interventions. However, existing MRN registration methods face challenges in concurrently achieving low user dependency, high accuracy, and clinical applicability. This study proposes and evaluates a novel registration method based on a laser crosshair simulator, evaluating its feasibility and accuracy. A novel registration method employing a laser crosshair simulator was introduced, designed to replicate the scanner frame’s position on the patient. The system autonomously calculates the transformation, mapping coordinates from the tracking space to the reference image space. A mathematical model and workflow for registration were designed, and a Universal Windows Platform (UWP) application was developed on HoloLens-2. Finally, a head phantom was used to measure the system’s target registration error (TRE). The proposed method was successfully implemented, obviating the need for user interactions with virtual objects during the registration process. Regarding accuracy, the average deviation was 3.7 ± 1.7 mm. This method shows encouraging results in efficiency and intuitiveness and marks a valuable advancement in low-cost, easy-to-use MRN systems. The potential for enhancing accuracy and adaptability in intervention procedures positions this approach as promising for improving surgical outcomes.

25 May 2024 in Scientific Data
Verified
Journal Article
Open access
PDF file
Ziyu QiZiyu Qi
Ziyu Qi
HJHaitao Jin
Haitao Jin
XXXinghua Xu
Xinghua Xu
QWQun Wang
Qun Wang
ZGZhichao Gan
Zhichao Gan
Miriam H. A. BoppMiriam H. A. Bopp
Miriam H. A. Bopp
Mixed reality navigation (MRN) technology is emerging as an increasingly significant and interesting topic in neurosurgery. MRN enables neurosurgeons to “see through” the head with an interactive, hybrid visualization environment that merges virtual- and physical-world elements. Offering immersive, intuitive, and reliable guidance for preoperative and intraoperative intervention of intracranial lesions, MRN showcases its potential as an economically efficient and user-friendly alternative to standard neuronavigation systems. However, the clinical research and development of MRN systems present challenges: recruiting a sufficient number of patients within a limited timeframe is difficult, and acquiring low-cost, commercially available, medically significant head phantoms is equally challenging. To accelerate the development of novel MRN systems and surmount these obstacles, the study presents a dataset designed for MRN system development and testing in neurosurgery. It includes CT and MRI data from 19 patients with intracranial lesions and derived 3D models of anatomical structures and validation references. The models are available in Wavefront object (OBJ) and Stereolithography (STL) formats, supporting the creation and assessment of neurosurgical MRN applications.
1