Fengjuan Wang

Prof. Dr. Fengjuan Wang

orcid

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 February 2020 in IEEE Transactions on Terahertz Science and Technology
Verified
Journal Article
Closed access
FWFengjuan Wang
Fengjuan Wang
Vasilis F. PavlidisVasilis F. Pavlidis
Vasilis F. Pavlidis
NYNingmei Yu
Ningmei Yu
A miniaturized substrate integrated waveguide (SIW) bandpass filter with an area of 0.682×0.210 mm2 is proposed based on Through-Silicon Via (TSV) technology for terahertz (THz) applications. The design method of the THz cavity filter based on rectangular TSV is introduced and the filtering characteristics are investigated by the finite element method (FEM) and mode matching method (MMM). The rectangular TSV is substituted by cylindrical structures and the THz cavity filter is fabricated and measured in order to investigate the possibility of integration with typical 3D IC manufacturing processes. The cavity filter utilizing cylindrical TSV exhibits a bandwidth of 0.051 THz centered at 0.331 THz, an insertion loss of 1.5 dB, and a reflection of higher than 15 dB in the passband.

27 June 2014 in IEEE Transactions on Electron Devices
Verified
Journal Article
Closed access
FWFengjuan Wang
Fengjuan Wang
ZZZhangming Zhu
Zhangming Zhu
YYYintang Yang
Yintang Yang
XYXiangkun Yin
Xiangkun Yin
XLXiaoxian Liu
Xiaoxian Liu
RDRuixue Ding
Ruixue Ding
Keep-out-zone (KOZ) is a conservative way to prevent any devices/cells from being impacted by the through-silicon via (TSV)-induced stress. In this paper, an effective approach was proposed of reducing the KOZ induced by coaxial TSV, by using the structure of coaxial-annular TSV, without decreasing the electrical performance of coaxial TSV. The analytical model was developed appropriate for the thermal stress induced by both coaxial and coaxial-annular TSVs, and was verified by the finite element method. The KOZs induced by coaxial and coaxial-annular TSVs were compared in detail, and the effects of Cu plasticity, TSV material, TSV size, and inner metal plating ratio of coaxial-annular TSV were also studied. The electrical characteristics of different TSVs were compared by employing ANSYS' HFSS, and a feasible fabrication process for coaxial-annular TSV was suggested. It could be concluded that: 1) a 1.6-μm (22.2%) drop of KOZ for coaxial-annular TSV could be reached as compared with that of coaxial TSV; 2) coaxialannular TSV was proved to offer the same superior signal integrity with coaxial TSV, improving S21 by about 93% at 5 GHz and 60% at 20 GHz compared with ordinary cylindrical and annular TSVs; and 3) the coaxial-annular TSV is realizable.

22 August 2019 in Evidence-Based Complementary and Alternative Medicine
Verified
Journal Article
Open access
CZChengcheng Zhang
Chengcheng Zhang
BZBaoju Zhang
Baoju Zhang
GLGang Li
Gang Li
LLLing Lin
Ling Lin
CZCuiping Zhang
Cuiping Zhang
FWFengjuan Wang
Fengjuan Wang
Effect of Polysaccharides from Bletilla striata on the Healing of Dermal Wounds in Mice: Bletilla striata has been largely used in traditional folk medicine in China as a wound healing agent and to treat gastritis and several other health problems. Some studies have shown that plant polysaccharides may have the ability to promote wound healing. The aim of this work was to evaluate the wound healing activity of the polysaccharide extracted from Bletilla striata. Firstly, a Bletilla striata polysaccharide was extracted by water extraction and alcohol precipitation and characterized by Fourier transform infrared spectroscopy. The Bletilla striata polysaccharide was then tested for cell migration and proliferation using the mouse fibroblast cell line. Then, the Bletilla striata hydrogel was fabricated for acute wound health care of the mouse full-thickness excision. The results showed that the BSP enhanced the proliferation and migration of L929 cells. The superior wound healing capacity of the BSP hydrogel was demonstrated that it significantly accelerated the wound healing process in vivo in full-thickness skin defect wounded models. Compared to the saline group, the BSP hydrogel could accelerate wound healing and promote re-epithelialization and collagen deposition by means of TGF-β/Smad signal pathway activation. Taken together, BSP hydrogel would be a useful pharmaceutic candidate for acute cutaneous wound health care.

5 December 2025 in IEEE Microwave and Wireless Technology Letters
Verified
Journal Article
Closed access
LLLe Liu
Le Liu
FWFengjuan Wang
Fengjuan Wang
XYXiangkun Yin
Xiangkun Yin
MXMing Xu
Ming Xu
YYYuan Yang
Yuan Yang
YLYan Li
Yan Li
This letter presents a compact, low-loss flexible filter based on a double-interdigital coupling stepped-impedance resonator (SIR) and through-polyimide via (TPV) technology. With a fractional bandwidth (FBW) of 12.5% at 2.5 GHz, the filter achieves a low insertion loss of 1.8 dB in the flat state and only 1.95 dB under bending. Its electrical performance remains highly stable under deformation, while the structure attains a 40% size reduction over the state-of-the-art designs, offering a promising solution for wearable wireless systems demanding flexibility and spectral selectivity.

4 October 2021 in IEEE Microwave and Wireless Components Letters
Verified
Journal Article
Closed access
XYXiangkun Yin
Xiangkun Yin
FWFengjuan Wang
Fengjuan Wang
QLQijun Lu
Qijun Lu
XLXiaoxian Liu
Xiaoxian Liu
YLYang Liu
Yang Liu
Yintang YangYintang Yang
Yintang Yang
By using integrated lumped elements based on through-silicon via (TSV) technology, a 3-D low-pass filter (LPF) with ultracompact size and ultrawide stopband is proposed. The 3-D magnetic coupling is enhanced between microsize spiral inductors to increase the mutual inductance and improve the high-frequency performance. A coaxial TSV with enhanced capacitance in high resistivity silicon (HRS) is utilized both as capacitor and as a vertical interconnection without any overhead in area and routing. The 3-D nature of the proposed filter yields a miniaturized size of $0.2\times0.10$ mm 2 . The LPF is analyzed with equivalent circuit model and validated with the well-matched $S$ -parameters obtained by finite element method simulation and measurement. With −3-dB cutoff frequency at 2.6 GHz, the LPF exhibits an insertion loss below 1 dB, a reflection loss over 17 dB in the passband, and a suppression level over 20 dB from 5.28 up to 40 GHz in the stopband.

20 November 2024 in IEEE Transactions on Components, Packaging and Manufacturing Technology
Verified
Journal Article
Closed access
YDYue Deng
Yue Deng
FWFengjuan Wang
Fengjuan Wang
XYXiangkun Yin
Xiangkun Yin
YYYuan Yang
Yuan Yang
NYNingmei Yu
Ningmei Yu
YLYan Li
Yan Li
Transformers are the key passive devices in many radio frequency integrated circuit (RF IC) applications. In this paper, a kind of ultra-high coupling coefficient and symmetric transformer based on through-silicon via (TSV) is proposed. HFSS software is used to model and simulate the transformers with turn ratios of 1:1, 1:2 and 1:3, and the three structures are manufactured and measured. The measurement results show that the coupling coefficients of the three are 0.956, 0.971 and 0.954, and the areas are 0.007 mm 2 , 0.012 mm 2 and 0.015 mm 2 . Compared with other literatures, it has the characteristics of high coupling and miniaturization.