Ibrahim ALHAMARNEH

Prof. Ibrahim ALHAMARNEH

orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 August 2016 in Journal of Environmental Radioactivity
Verified
Journal Article
Closed access
IAIbrahim ALHAMARNEH
Ibrahim ALHAMARNEH
NAN. Alkhomashi
N. Alkhomashi
Fahad Ibraheem AlmasoudFahad Ibraheem Almasoud
Fahad Ibraheem Almasoud

14 July 2021 in Materials
Verified
Journal Article
Open access
PDF file
Mohamed ElsafiMohamed Elsafi
Mohamed Elsafi
MAMuteb Alrashedi
Muteb Alrashedi
Mohammad Ibrahim AbualsayedMohammad Ibrahim Abualsayed
Mohammad Ibrahim Abualsayed
IAIbrahim ALHAMARNEH
Ibrahim ALHAMARNEH
Mohamed ElnahalMohamed Elnahal
Mohamed Elnahal
AAAhmad Askary
Ahmad Askary
This paper aims to study the radiation shielding characteristics and buildup factor of some types of granite in Egypt. The mass attenuation coefficient (MAC) for three types of granite (gandola, white halayeb, and red aswani) was experimentally determined, and the experimental results were validated by XCOM software. The relative deviation between the two methods does not exceed 3% in all discussed granite samples, which means that MAC calculated through the experimental and XCOM are in suitable agreement. The effective atomic number (Zeff) varies from 13.64 to 10.69, 13.68 to 10.59, and 13.45 and 10.66 for gandola, white halayeb, and red aswani, respectively. As well as the equivalent atomic number (Zeq) was calculated in a wide range of energy to deduce the exposure (EBF) and energy absorption (EABF) buildup factors for the studied granite materials. The linear attenuation coefficient (LAC), half-value layer (HVL), mean free path (MFP) were calculated at each investigated energy and showed that the most effective shielding ability at high energy was red aswani, while at low energy, the shielding ability was nearly constant for studied granites. The present study forms the first endeavor to obtain the radiation shielding properties of the studied materials to be used in practical applications.

1 February 2016 in Chemosphere
Verified
Journal Article
Closed access
NAN. Alkhomashi
N. Alkhomashi
IAIbrahim ALHAMARNEH
Ibrahim ALHAMARNEH
Fahad Ibraheem AlmasoudFahad Ibraheem Almasoud
Fahad Ibraheem Almasoud

31 July 2017 in Environmental Earth Sciences
Verified
Journal Article
Closed access
PDF file
IAIbrahim ALHAMARNEH
Ibrahim ALHAMARNEH

25 October 2017 in Nuclear Science and Techniques
Verified
Journal Article
Closed access
PDF file
IAIbrahim ALHAMARNEH
Ibrahim ALHAMARNEH
MMMohammad W. Marashdeh
Mohammad W. Marashdeh
Fahad Ibraheem AlmasoudFahad Ibraheem Almasoud
Fahad Ibraheem Almasoud
AAAhmad Alkaoud
Ahmad Alkaoud

15 November 2021 in Materials
Verified
Journal Article
Open access
PDF file
MMMohammad Marashdeh
Mohammad Marashdeh
IAIbrahim ALHAMARNEH
Ibrahim ALHAMARNEH
In this study, the gamma radiation properties of four types of surgical-grade stainless steel (304, 304L, 316 and 316L) were investigated. The effective atomic number Zeff, effective electron density Neff and half-value layer (HVL) of four types of surgical-grade stainless steel were determined via the mass attenuation coefficient (μ/ρ). The μ/ρ coefficients were determined experimentally using an X-ray fluorescence (XRF) technique and theoretically via the WinXCOM program. The Kα1 of XRF photons in the energy range between 17.50 and 25.29 keV was used from pure metal plates of molybdenum (Mo), palladium (Pd), silver (Ag) and tin (Sn). A comparison between the experimental and theoretical values of μ/ρ revealed that the experimental values were lower than the theoretical calculations. The relative differences between the theoretical and experimental values were found to decrease with increasing photon energy. The lowest percentage difference between the experimental and theoretical values of μ/ρ was between −6.17% and −9.76% and was obtained at a photon energy of 25.29 keV. Sample 316L showed the highest value of μ/ρ at the energies 21.20, 22.19 and 25.29 keV. In addition, the measured results of Zeff and Neff for all samples behaved similarly in the given energy range and were found to be in good agreement with the calculations. The equivalent atomic number (Zeff) of the investigated stainless-steel samples was calculated using the interpolation method to compare the samples at the same source energy. The 316L stainless steel had higher values of μ/ρ, Zeff and Zeq and lower values of HVL compared with the other samples. Therefore, it is concluded that the 316L sample is more effective in absorbing gamma radiation.