Yilong Qiu

Dr. Yilong Qiu


Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 September 2021 in Processes
Verified
Journal Article
Open access
PDF file
YQYilong Qiu
Yilong Qiu
HCHuiyu Chen
Huiyu Chen
WLWangxu li
Wangxu li
FWFeng Wu
Feng Wu
ZLzhenggui Li
zhenggui Li
When a PIV flowmeter is used to measure a large flow of natural gas, the flow field fluctuation and particle distribution have a significant influence on the measurement accuracy and the particle injection mode plays a key role in the flow field fluctuation and particle distribution. To improve the measurement accuracy of PIV flowmeters, the method of filling tracer particles in single pipes, multiple pipes, and L pipes of a natural gas DN100 pipeline under high-pressure working conditions was compared and analyzed through numerical calculation and testing. The results show that the disturbance distance of filling particles in L pipes was the shortest, but the particle distribution area was small, whereas the flow metering error was large. By shortening the intersection distance between the L tube injection flow field and the main flow field, the problem that the particles failed to fill the test area was effectively solved, and the peak turbulence intensity at the intersection of the flow field decreased from 13.4% to 8%. Furthermore, the optimized structure was used to measure a flow of 100–600 m3/h with different flow rates. The relative error between the flowmeter and the ultrasonic flowmeter was approximately 2%, and the metering deviation was significantly improved.

19 February 2024 in Processes
Verified
Journal Article
Open access
PDF file
LLLihao Li
Lihao Li
JLJiaxing Lu
Jiaxing Lu
HZHaoyu Zhao
Haoyu Zhao
YQYilong Qiu
Yilong Qiu
The impact of particle addition jets on the flow field in natural gas pipelines was investigated, and the structural information of the flow field at different flow velocities in a symmetric jet flow was analyzed via numerical simulation. The results of coherent structures in the high-pressure natural gas pipeline reveal vortex structures of varying sizes both upstream and downstream of the jet flow. To determine the spatial distribution of the main vortex structures in the flow field, proper orthogonal decomposition (POD) mode analysis was performed on the unsteady numerical results. Moreover, the detailed spatial characteristics of the coherent vortex structures represented by each mode were obtained. The results indicate that the large-scale vortex structures within the pipeline are balanced and stable, with their energy increasing as the jet flow velocity increases. Additionally, higher-order modes exhibit significant shedding of small-scale vortex structures downstream of the jet flow. In this research, coherent structures present in symmetric particle addition jets are provided, offering theoretical support for future investigations on the distribution of particle image velocimetry (PIV) flowmeters.

7 January 2024 in Processes
Verified
Journal Article
Open access
PDF file
HCHuiyu Chen
Huiyu Chen
YQYilong Qiu
Yilong Qiu
HWHui Wang
Hui Wang
MGMengjie Gao
Mengjie Gao
The application of particle image velocimetry (PIV) technology for monitoring natural gas flow is a new method of flow measurement. Since the principle of this technology was proposed, there are still some potential issues. This article investigates the influence of a manifold structure on the measurement results of a PIV flowmeter. A comparison is performed between concentric and eccentric manifold structures, using a circular straight pipe as reference, in terms of the measurement error of the PIV flowmeter and the internal flow state of the natural gas. The results demonstrate that the manifold structure significantly affects the measurement reliability of the PIV flowmeter, especially the eccentric manifold structure. Under flow conditions ranging from 100 to 600 m3/h, the maximum measurement errors caused by the concentric and eccentric manifold structures are 2.49% and 3.05%, respectively, which show a noticeable increase compared to the maximum measurement error of 2.08% observed for the circular straight pipe. Additionally, the influence of the manifold structure on the downstream flow field is also evident, as the eccentric manifold structure increases the turbulence intensity of the downstream fluid by nearly twofold. The addition of a rectifier can effectively improve the flow state and enhance the measurement reliability of the PIV flowmeter. For the concentric manifold structure under the condition of a 600 m3/h flow rate, the inclusion of a rectifier produces highly accurate measurement results, similar to those obtained by an ultrasonic flowmeter, with an error value close to zero. This study provides technical support for further promoting the practical application of PIV flowmeters.

1 December 2023 in AIP Advances
Verified
Journal Article
Open access
PDF file
YQYilong Qiu
Yilong Qiu
JRJia Ren
Jia Ren
XZXi Zhang
Xi Zhang
SCSiyu Chen
Siyu Chen
To research the flow-induced vibration characteristics of the natural gas loop, unsteady numerical simulation is carried out on the loop calculation model under different ambient temperatures and different flow rates, and the influence of different flow rates on the dynamic characteristics of the flow field and its induced vibration characteristics is obtained. The results show that the inherent frequency of the natural gas loop increases slightly under the action of heat–fluid–solid coupling. The maximum equivalent stress of the loop increases with the increase in ambient temperature under low flow conditions, but it is almost constant under high flow conditions. The smaller the cross-sectional area of the loop pipeline inlet, the greater the pressure, and the more significant the pressure gradient along the flow direction. The pressure pulsation of monitoring points in the pipeline under different flow rates presents different rules, and the pulsation amplitude of pipes with different diameters is different, among which the amplitude of the pipe with a diameter of 250 mm is the largest and that of the pipe with a diameter of 150 mm is the smallest. The pressure pulsation signals are concentrated in the low-frequency band of 0–10 Hz, and the range of the band decreases with the increase in the flow rate. The vibration frequency of the loop structure is close to the fluid pressure pulsation frequency and the inherent frequency under the action of heat–fluid–solid coupling, which causes a resonance of about 2 Hz.

1 April 2023 in AIP Advances
Verified
Journal Article
Open access
PDF file
HCHuiyu Chen
Huiyu Chen
YQYilong Qiu
Yilong Qiu
HWHui Wang
Hui Wang
To measure the natural gas flow in the natural gas pipeline, a flow measurement method based on a laser Doppler velocimeter (LDV) is proposed, and the flow field in the natural gas pipeline is accurately measured. The flow laws of the flow field in the pipeline are obtained. In this paper, the influence of the jet flow on the flow field in the main pipe during the injection of tracer particles is analyzed by numerical calculations, and the reliability of the calculation is verified by the LDV test. The results show that the influence of the jet on the flow field in the main pipe weakens rapidly within a short distance, which provides good conditions for measuring the flow in the LDV test pipeline. The error between the flow measured by LDV and the turbine standard device is within 0.47%. Meanwhile, the uncertainty of the LDV measurement test system of a natural gas pipeline is evaluated. The system uncertainty is less than 2%, which satisfies the uncertainty requirements of the metering system, verifying the feasibility of the LDV metering flow and providing a reliable basis for the accurate metering of natural gas.