When a PIV flowmeter is used to measure a large flow of natural gas, the flow field fluctuation and particle distribution have a significant influence on the measurement accuracy and the particle injection mode plays a key role in the flow field fluctuation and particle distribution. To improve the measurement accuracy of PIV flowmeters, the method of filling tracer particles in single pipes, multiple pipes, and L pipes of a natural gas DN100 pipeline under high-pressure working conditions was compared and analyzed through numerical calculation and testing. The results show that the disturbance distance of filling particles in L pipes was the shortest, but the particle distribution area was small, whereas the flow metering error was large. By shortening the intersection distance between the L tube injection flow field and the main flow field, the problem that the particles failed to fill the test area was effectively solved, and the peak turbulence intensity at the intersection of the flow field decreased from 13.4% to 8%. Furthermore, the optimized structure was used to measure a flow of 100–600 m3/h with different flow rates. The relative error between the flowmeter and the ultrasonic flowmeter was approximately 2%, and the metering deviation was significantly improved.
With increasing global energy demand and depletion of onshore oil–gas resources, deep-sea hydrocarbon exploration and development have become strategically vital. As core subsea transportation equipment, the performance of helico-axial multiphase pumps directly determines the efficiency and economic feasibility of deep-sea extraction. However, non-uniform inflow patterns caused by uneven gas–liquid distribution in pipelines degrade pressure-boosting capability and reduce pump efficiency under actual operating conditions. To address this, an optimization method employing helical static mixers was developed. A mixer with a 180° helical angle was designed and installed upstream of the pump inlet. Numerical simulations demonstrate that the mixer enhances gas-phase distribution uniformity in stratified flow, improving efficiency and head across varying gas void fractions (GVFs). At a stratification height ratio (Ψ) of 0.32, efficiency increased by 15.41% and head rose by 15.64 m, while turbulent kinetic energy (TKE) at the impeller outlet decreased by up to 50%. For slug flow conditions, the mixer effectively suppressed gas volume fraction fluctuations, consistently improving efficiency under different slug flow coefficients (φ) with a maximum head increase of 9.82%. The optimized flow field exhibits uniform gas–liquid velocity distribution, stable pressure boosting, and significantly reduced TKE intensity within impeller passages.
The application of particle image velocimetry (PIV) technology for monitoring natural gas flow is a new method of flow measurement. Since the principle of this technology was proposed, there are still some potential issues. This article investigates the influence of a manifold structure on the measurement results of a PIV flowmeter. A comparison is performed between concentric and eccentric manifold structures, using a circular straight pipe as reference, in terms of the measurement error of the PIV flowmeter and the internal flow state of the natural gas. The results demonstrate that the manifold structure significantly affects the measurement reliability of the PIV flowmeter, especially the eccentric manifold structure. Under flow conditions ranging from 100 to 600 m3/h, the maximum measurement errors caused by the concentric and eccentric manifold structures are 2.49% and 3.05%, respectively, which show a noticeable increase compared to the maximum measurement error of 2.08% observed for the circular straight pipe. Additionally, the influence of the manifold structure on the downstream flow field is also evident, as the eccentric manifold structure increases the turbulence intensity of the downstream fluid by nearly twofold. The addition of a rectifier can effectively improve the flow state and enhance the measurement reliability of the PIV flowmeter. For the concentric manifold structure under the condition of a 600 m3/h flow rate, the inclusion of a rectifier produces highly accurate measurement results, similar to those obtained by an ultrasonic flowmeter, with an error value close to zero. This study provides technical support for further promoting the practical application of PIV flowmeters.