Raj Ramanan

Dr. Raj Ramanan

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 November 2023 in American Journal of Respiratory and Critical Care Medicine
Verified
Journal Article
Closed access
GMGennaro Martucci
Gennaro Martucci
MGMarco Giani
Marco Giani
MSMatthieu Schmidt
Matthieu Schmidt
KTKenichi Tanaka
Kenichi Tanaka
ATAli Tabatabai
Ali Tabatabai
I(International ECMO Network (ECMONet)
International ECMO Network (ECMONet)
Definitive guidelines for anticoagulation management during veno-venous extracorporeal membrane oxygenation (VV ECMO) are lacking, while bleeding complications continue to pose major challenges. To describe anticoagulation modalities and bleeding events in adults receiving VV ECMO. International prospective observational study in 41 centers, from December 2018 to February 2021. Anticoagulation was recorded daily in terms of type, dosage, and monitoring strategy. Bleeding events were reported according to site, severity, and impact on mortality. The study cohort included 652 patients, and 8471 days on ECMO were analyzed. Unfractionated heparin (UFH) was the initial anticoagulant in 77% of patients, and the most used anticoagulant during the ECMO course (6221 days, 73%). Activated partial thromboplastin time (aPTT) was the most common test for monitoring coagulation (86% of days): the median value was 52 seconds (39-61), but dropped by 5.3 seconds after the first bleeding event (95% CI -7.4 to -3.2, p< 0.01). Bleeding occurred on 1202 days (16.5 %). Overall, 342 patients (52.5 %) experienced at least one bleeding event (one episode every 215 hours on ECMO), of which 10 (1.6%) were fatal. In a multiple penalized Cox proportional hazard model, higher aPTT was a potentially modifiable risk factor for the first episode of bleeding (for 20 seconds increase, hazard ratio 1.07). Anticoagulation during VV ECMO was a dynamic process, with frequent stopping in cases of bleeding, and restart according to the clinical picture. Future studies might explore lower aPTT targets to reduce the risk of bleeding.

27 February 2021 in Membranes
Verified
Journal Article
Open access
PDF file
ASAlexander Supady
Alexander Supady
JDJeffrey D. DellaVolpe
Jeffrey D. DellaVolpe
Fabio Silvio TacconeFabio Silvio Taccone
Fabio Silvio Taccone
DSDominik Scharpf
Dominik Scharpf
MUMatthias Ulmer
Matthias Ulmer
DSDawid L. Staudacher
Dawid L. Staudacher
The role of veno-venous extracorporeal membrane oxygenation therapy (V-V ECMO) in severe COVID-19 acute respiratory distress syndrome (ARDS) is still under debate and conclusive data from large cohorts are scarce. Furthermore, criteria for the selection of patients that benefit most from this highly invasive and resource-demanding therapy are yet to be defined. In this study, we assess survival in an international multicenter cohort of COVID-19 patients treated with V-V ECMO and evaluate the performance of several clinical scores to predict 30-day survival. Methods: This is an investigator-initiated retrospective non-interventional international multicenter registry study (NCT04405973, first registered 28 May 2020). In 127 patients treated with V-V ECMO at 15 centers in Germany, Switzerland, Italy, Belgium, and the United States, we calculated the Sequential Organ Failure Assessment (SOFA) Score, Simplified Acute Physiology Score II (SAPS II), Acute Physiology And Chronic Health Evaluation II (APACHE II) Score, Respiratory Extracorporeal Membrane Oxygenation Survival Prediction (RESP) Score, Predicting Death for Severe ARDS on V-V ECMO (PRESERVE) Score, and 30-day survival. Results: In our study cohort which enrolled 127 patients, overall 30-day survival was 54%. Median SOFA, SAPS II, APACHE II, RESP, and PRESERVE were 9, 36, 17, 1, and 4, respectively. The prognostic accuracy for all these scores (area under the receiver operating characteristic—AUROC) ranged between 0.548 and 0.605. Conclusions: The use of scores for the prediction of mortality cannot be recommended for treatment decisions in severe COVID-19 ARDS undergoing V-V ECMO; nevertheless, scoring results below or above a specific cut-off value may be considered as an additional tool in the evaluation of prognosis. Survival rates in this cohort of COVID-19 patients treated with V-V ECMO were slightly lower than those reported in non-COVID-19 ARDS patients treated with V-V ECMO.

28 April 2022 in Medicina
Verified
Journal Article
Open access
PDF file
GCGarrett Nicholas Coyan
Garrett Nicholas Coyan
NANeesha Anand
Neesha Anand
MIMahnoor Imran
Mahnoor Imran
HGHernando Gomez
Hernando Gomez
RRRaj Ramanan
Raj Ramanan
JBJohannes Bonatti
Johannes Bonatti
Background and Objectives: Post-infarct ventricular septal rupture (PIVSR) continues to have significant morbidity and mortality, despite decreased prevalence. Impella and venoarterial extracorporeal membranous oxygenation (VA-ECMO) have been proposed as strategies to correct hemodynamic derangements and bridge patients to delayed operative repair when success rates are higher. This review places VA-ECMO and Impella support strategies in the context of bridging patients to successful PIVSR repair, with an additional case report of successful bridging with the Impella device. Materials and Methods: We report a case of PIVSR repair utilizing 14 days of Impella support. We additionally conducted a systematic review of contemporary literature to describe the application of VA-ECMO and Impella devices in the pre-operative period prior to surgical PIVSR correction. Expert commentary on the advantages and disadvantages of each of these techniques is provided. Results: We identified 19 studies with 72 patients undergoing VA-ECMO as a bridge to PIVSR repair and 6 studies with 11 patients utilizing an Impella device as a bridge to PIVSR repair. Overall, outcomes in both groups were better than expected from patients who were historically managed with medicine and balloon pump therapy, however there was a significant heterogeneity between studies. Impella provided for excellent left ventricular unloading, but did result in some concerns for reversal of shunting. VA-ECMO resulted in improved end-organ perfusion, but carried increased risks of device-related complications and requirement for additional ventricular unloading. Conclusions: Patients presenting with PIVSR in cardiogenic shock requiring a MCS bridge to definitive surgical repair continue to pose a challenge to the multidisciplinary cardiovascular team as the diverse presentation and management issues require individualized care plans. Both VA-ECMO and the Impella family of devices play a role in the contemporary management of PIVSR and offer distinct advantages and disadvantages depending on the clinical scenario. The limited case numbers reported demonstrate feasibility, safety, and recommendations for optimal management.

14 September 2023 in CHEST Critical Care
Verified
Journal Article
Open access
MLMichael Lu
Michael Lu
CDCallie Drohan
Callie Drohan
WBWilliam Bain
William Bain
FSFaraaz A. Shah
Faraaz A. Shah
MBMatthew Bittner
Matthew Bittner
GKGeorgios D. Kitsios
Georgios D. Kitsios
Hospitalized patients with severe COVID-19 follow heterogeneous clinical trajectories, requiring different levels of respiratory support and experiencing diverse clinical outcomes. Differences in host immune responses to SARS-CoV-2 infection may account for the heterogeneous clinical course, but we have limited data on the dynamic evolution of systemic biomarkers and related subphenotypes. Improved understanding of the dynamic transitions of host subphenotypes in COVID-19 may allow for improved patient selection for targeted therapies. We examined the trajectories of host-response profiles in severe COVID-19 and evaluated their prognostic impact on clinical outcomes. In this prospective observational study, we enrolled 323 inpatients with COVID-19 receiving different levels of baseline respiratory support: (1) low-flow oxygen (37%), (2) noninvasive ventilation (NIV) or high-flow oxygen (HFO; 29%), (3) invasive mechanical ventilation (27%), and (4) extracorporeal membrane oxygenation (7%). We collected plasma samples on enrollment and at days 5 and 10 to measure host-response biomarkers. We classified patients by inflammatory subphenotypes using two validated predictive models. We examined clinical, biomarker, and subphenotype trajectories and outcomes during hospitalization. IL-6, procalcitonin, and angiopoietin 2 persistently were elevated in patients receiving higher levels of respiratory support, whereas soluble receptor of advanced glycation end products (sRAGE) levels displayed the inverse pattern. Patients receiving NIV or HFO at baseline showed the most dynamic clinical trajectory, with 24% eventually requiring intubation and exhibiting worse 60-day mortality than patients receiving invasive mechanical ventilation at baseline (67% vs 35%; P < .0001). sRAGE levels predicted NIV failure and worse 60-day mortality for patients receiving NIV or HFO, whereas IL-6 levels were predictive in all patients regardless of level of support (P < .01). Patients classified to a hyperinflammatory subphenotype at baseline (< 10%) showed worse 60-day survival (P < .0001) and 50% of them remained classified as hyperinflammatory at 5 days after enrollment. Longitudinal study of the systemic host response in COVID-19 revealed substantial and predictive interindividual variability influenced by baseline levels of respiratory support.

12 July 2021 in The International Journal of Artificial Organs
Verified
Journal Article
Closed access
PDF file
CFCarly Fabrizio
Carly Fabrizio
MLMarissa N Levito
Marissa N Levito
RRRyan Rivosecchi
Ryan Rivosecchi
MBMichael Bashline
Michael Bashline
BSBrittany Slocum
Brittany Slocum
EHEdward T Horn
Edward T Horn
Temporary mechanical circulatory support (tMCS) devices are used for the management of cardiogenic shock. The Impella 5.0 (Abiomed; Danvers, MA) (IMP5) is a commonly used, surgically implanted, tMCS device that requires systemic anticoagulation and purge solution to avoid pump failure. To avoid heparin-induced thrombocytopenia (HIT) from unfractionated heparin (UFH) use, our program has explored the utility of bivalirudin (BIV) for systemic anticoagulation in IMP5. This single center, retrospective study included patients supported on IMP5 with BIV based AC. The efficacy and safety end points were recovery, bridge to left ventricular assist device (LVAD), cardiac transplant (HTX), or death as well as clinically significant bleeding, incidence of Tissue Plasminogen Activator (tPA) use for suspected pump thrombosis, stroke, and device failure. There were 31 patients included, and 26 (84%) received BIV purge solutions. The median duration of IMP5 was 6 (IQR 4–10) days. Most patients were bridged to LVAD (39%, 12); 16% (5) were bridged to HTX, 16% (5) recovered, and 29% (9) died. One patient (3%) suffered from ischemic stroke and 12% (4) patients developed clinically significant bleeding. tPA was administered to 8 (26%) patients. Logistic regression analysis demonstrated that duration of IMP5 was a significant predictor of tPA use (OR 1.28; 95% Confidence Interval 1.04–1.56). There were no cases of pump failure. Our experience highlights the feasibility of utilizing BIV for routine AC use in IMP5.

23 February 2024 in Artificial Organs
Verified
Journal Article
Closed access
YHYeahwa Hong
Yeahwa Hong
NANishant Agrawal
Nishant Agrawal
NHNicholas Ryan Hess
Nicholas Ryan Hess
LZLuke A. Ziegler
Luke A. Ziegler
MSMcKenzie M. Sicke
McKenzie M. Sicke
DKDavid J. Kaczorowski
David J. Kaczorowski