Roberto Nascimbene

Prof. Dr. Roberto Nascimbene

IUSS Pavia, Inst Adv Study, UME Sch, ROSE Programme, Via Ferrata 1, I-27100 Pavia, Italy
+1
orcid

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 April 2018 in Bulletin of Earthquake Engineering
Verified
Journal Article
Closed access
PDF file
DPD. Perrone
D. Perrone
PCP. M. Calvi
P. M. Calvi
Roberto NascimbeneRoberto Nascimbene
Roberto Nascimbene
EFE. C. Fischer
E. C. Fischer
GMG. Magliulo
G. Magliulo

1 October 2015 in Journal of Performance of Constructed Facilities
Verified
Journal Article
Closed access
ABAndrea Belleri
Andrea Belleri
Emanuele BrunesiEmanuele Brunesi
Emanuele Brunesi
Roberto NascimbeneRoberto Nascimbene
Roberto Nascimbene
MPMarco Pagani
Marco Pagani
Paolo RivaPaolo Riva
Paolo Riva
Recent major earthquakes in the Italian territory have reaffirmed the seismic vulnerability of precast industrial buildings typical of past Italian building practices, highlighting structural deficiencies observed during previous events and primarily related to the transfer of horizontal forces between structural and nonstructural elements. An intrinsic lack of shear and ductility capacity has been observed in simply supported beam-to-joist and beam-to-column connections, primarily constituted by vertical steel dowels or solely relying on shear friction, with or without neoprene pads. These connections were designed neglecting seismic loads and their premature failure was observed during recent seismic events to cause a loss of support of beam elements, owing to the relative movements of elements, and the collapse of part of the buildings, primarily the roof. The seismic displacement demand of the industrial buildings under consideration is larger than traditional RC frame structures owing to their higher flexibility, according to both higher interstory height and to a cantilevered static scheme. Furthermore, this high flexibility may also result in displacement incompatibility between structural and nonstructural elements, such as precast cladding panels, causing their connection failure. On the basis of detailed field observations on a relevant number of buildings, collected just after the earthquakes, seven representative industrial facilities are examined to outline the primary vulnerabilities of one-story precast concrete structures not designed and detailed for seismic loads.

20 April 2011 in Bulletin of Earthquake Engineering
Verified
Journal Article
Closed access
PDF file
KWK. K. Wijesundara
K. K. Wijesundara
Roberto NascimbeneRoberto Nascimbene
Roberto Nascimbene
TSTimothy J. Sullivan
Timothy J. Sullivan

28 January 2014 in Materials and Structures
Verified
Journal Article
Closed access
PDF file
Emanuele BrunesiEmanuele Brunesi
Emanuele Brunesi
DBD. Bolognini
D. Bolognini
Roberto NascimbeneRoberto Nascimbene
Roberto Nascimbene

5 June 2017 in Bulletin of Earthquake Engineering
Verified
Journal Article
Closed access
PDF file
Emanuele BrunesiEmanuele Brunesi
Emanuele Brunesi
Roberto NascimbeneRoberto Nascimbene
Roberto Nascimbene

6 April 2018 in Bulletin of Earthquake Engineering
Verified
Journal Article
Closed access
PDF file
Emanuele BrunesiEmanuele Brunesi
Emanuele Brunesi
SPS. Peloso
S. Peloso
RPRui Pinho
Rui Pinho
Roberto NascimbeneRoberto Nascimbene
Roberto Nascimbene