Paolo Riva

Prof. Dr. Paolo Riva

Department of Engineering and Applied Sciences, University of Bergamo, Bergamo, Italy
orcid

Research Focus & Metrics

Academic Career Length

39Years (1988-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 October 2014 in Engineering Structures
Verified
Journal Article
Closed access
AMAlberto Meda
Alberto Meda
SMSerena Mostosi
Serena Mostosi
ZRZila Rinaldi
Zila Rinaldi
Paolo RivaPaolo Riva
Paolo Riva

1 October 2015 in Journal of Performance of Constructed Facilities
Verified
Journal Article
Closed access
ABAndrea Belleri
Andrea Belleri
Emanuele BrunesiEmanuele Brunesi
Emanuele Brunesi
Roberto NascimbeneRoberto Nascimbene
Roberto Nascimbene
MPMarco Pagani
Marco Pagani
Paolo RivaPaolo Riva
Paolo Riva
Recent major earthquakes in the Italian territory have reaffirmed the seismic vulnerability of precast industrial buildings typical of past Italian building practices, highlighting structural deficiencies observed during previous events and primarily related to the transfer of horizontal forces between structural and nonstructural elements. An intrinsic lack of shear and ductility capacity has been observed in simply supported beam-to-joist and beam-to-column connections, primarily constituted by vertical steel dowels or solely relying on shear friction, with or without neoprene pads. These connections were designed neglecting seismic loads and their premature failure was observed during recent seismic events to cause a loss of support of beam elements, owing to the relative movements of elements, and the collapse of part of the buildings, primarily the roof. The seismic displacement demand of the industrial buildings under consideration is larger than traditional RC frame structures owing to their higher flexibility, according to both higher interstory height and to a cantilevered static scheme. Furthermore, this high flexibility may also result in displacement incompatibility between structural and nonstructural elements, such as precast cladding panels, causing their connection failure. On the basis of detailed field observations on a relevant number of buildings, collected just after the earthquakes, seven representative industrial facilities are examined to outline the primary vulnerabilities of one-story precast concrete structures not designed and detailed for seismic loads.

1 January 2012 in PCI Journal
Verified
Journal Article
Closed access
ABAndrea Belleri
Andrea Belleri
Paolo RivaPaolo Riva
Paolo Riva
PCI Journal Paper Title: Seismic performance and retrofit of precast concrete grouted sleeve connections

13 May 2015 in Materials and Structures
Verified
Journal Article
Closed access
PDF file
AMAlberto Meda
Alberto Meda
SMSerena Mostosi
Serena Mostosi
ZRZila Rinaldi
Zila Rinaldi
Paolo RivaPaolo Riva
Paolo Riva

1 April 2019 in Cement and Concrete Composites
Verified
Journal Article
Closed access
DSDavide Sirtoli
Davide Sirtoli
MWMateusz Wyrzykowski
Mateusz Wyrzykowski
Paolo RivaPaolo Riva
Paolo Riva
STSergio Tortelli
Sergio Tortelli
MMMaurizio Marchi
Maurizio Marchi
PLPietro Lura
Pietro Lura

1 April 2005 in Materials and Structures
Verified
Journal Article
Closed access
PDF file
AMA. Meda
A. Meda
FMF. Minelli
F. Minelli
GPG. A. Plizzari
G. A. Plizzari
Paolo RivaPaolo Riva
Paolo Riva