This paper reports two experimental fires conducted at field-scale in Corsica, across a particular mountain shrubland. The orientation of the experimental plots was chosen in such a way that the wind was aligned along the main slope direction in order to obtain a high intensity fire. The first objective was to study the high intensity fire behavior by evaluating the propagation conditions related to its speed and intensity, as well as the geometry of the fire front and its impact on different targets. Therefore, an experimental protocol was designed to determine the properties of the fire spread using UAV cameras and its impact using heat flux gauges. Another objective was to study these experiments numerically using a fully physical fire model, namely FireStar3D. Numerical results concerning the fire dynamics, particularly the ROS, were also compared to other predictions of the FireStar2D model. The comparison with experimental measurements showed the robustness of the 3D approach with a maximum difference of 5.2% for the head fire ROS. The fire intensities obtained revealed that these experiments are representative of high intensity fires, which are very difficult to control in the case of real wildfires. Other parameters investigated numerically (flame geometry and heat fluxes) were also in fairly good agreement with the experimental measurements and confirm the capacity of FireStar3D to predict surface fires of high intensity.
A safe separation distance (SSD) needs to be considered during firefighting activities (fire suppression or people evacuation) against wildfires. The SSD is of critical interest for both humans and assets located in the wildland–urban interfaces (WUI). In most cases, the safety zone models and guidelines assume a flat terrain and only radiant heating. Nevertheless, injuries or damage do not result exclusively from radiant heating. Indeed, convection must be also considered as a significant contribution of heat transfer, particularly in the presence of the combined effects of sloping terrain and a high wind velocity. In this work, a critical case study is considered for the village of Sari-Solenzara in Corsica (France). This site location was selected by the operational staff since high-intensity fire spread is likely to occur in the WUI during wind-blown conditions. This study was carried out for 4 m high shrubland, a sloping terrain of 12° and a wind speed of 16.6 m/s. The numerical simulations were performed using a fully physical fire model, namely, FireStar2D, to investigate a case of fire spreading, which is thought to be representative of most high wildfire risk situations in Corsica. This study is based on the evaluation of the total (radiative and convective) heat flux received by two types of targets (human bodies and buildings) located ahead of the fire front. The results obtained revealed that the radiation was the dominant heat transfer mode in the evaluation of the SSD. In addition, the predictions were consistent with the criterion established by the operational experts, which assumes that in Corsica, a minimum SSD of 50 m is required to keep an equipped firefighter without injury in a fuelbreak named ZAL. This numerical work also provides correlations relating the total heat flux to the SSD.
Climate change causes more frequent and destructive wildfires even transforming them into megafire. Moreover, all biomass fires produce emissions of carbon compounds in the form of soot to the atmosphere with a significant impact on the environment and human health. Indeed, the soot is causing the formation of PAHs from (a) the high temperature thermal alteration of natural product precursors in the source organic matter and (b) the recombination of molecular fragments in the smoke. However, these molecules are known to have carcinogenic effects on human health. It is therefore interesting to quantify the 16 PAHs concentration extracted from soot emitted in open diffusion flame of biomass combustion. To achieve this objective, an analytical method developed for the study of kerosene combustion has been adapted for soot from biomass. This new method allowed to quantify the 16 PAHs defined as priority pollutants by the US EPA for their carcinogenic mutagenic effect and on human health.
25 September 2022 in Journal of Analytical and Applied Pyrolysis
This study presents the Moisture Dynamic Model (MDM), a new semi-physical formulation designed to estimate Fuel Moisture Content (FMC) using only air temperature and relative humidity. The core innovation of this work lies in the introduction of an Arrhenius-type kinetic term into a fuel moisture prediction framework, allowing temperature-driven desorption processes to be explicitly represented within a lightweight operational model. Its predictive capability was assessed through experimental campaigns on Cistus monspeliensis shrublands in Corsica and validated using FireStar3D simulations. A second major contribution is the coupling of the MDM with the physical wildfire simulator FireStar3D to quantify how FMC prediction errors propagate into fire spread predictions. The MDM accurately reproduced the seasonal variability of FMC, achieving strong correlation with experimental data during dry summer periods. When coupled with FireStar3D, discrepancies in the predicted rate of spread remained below 4% under high-risk meteorological conditions. While the model performed robustly during summer, its accuracy decreased during spring, when rainfall events and microclimatic variability introduced greater uncertainty. This work represents a proof of concept demonstrating the potential of a simple physically interpretable FMC model for operational fire behaviour prediction.