On the basis of previous studies, a staggered honeycomb-like flow field with drop-shaped gas distribution zone is proposed in this paper, and the staggered honeycomb-like flow channel can make the oxygen concentration higher, and the drop-shaped gas distribution zone can improve the uniformity of reaction gas in the flow field. A three-dimensional (3D), non-isothermal two-phase numerical model is established to study the flow field performance. First, the reaction gases in the flow field are analyzed, and it is found that the proposed flow field structure can effectively improve the concentration and uniformity of reactants. Second, the volume fraction of liquid water at the (GDL)/channel (CH) interface is analyzed, and it is found that compared with the model of the symmetrical honeycomb channel without considering the gas distribution zone, the proposed model has better water removal effect at the cathode. Finally, the effects of the proposed flow field structure on the membrane properties are discussed. In addition, the temperature uniformity and liquid water removal of PEMFC are improved under the condition of reverse flow of cathode and anode reaction gases. Graphical Abstract
8 February 2021 in International Journal of Thermophysics
Passive thermal management using a phase-change material (PCM) for proton exchange membrane fuel cells (PEMFCs) has been proposed and widely used in the thermal management of Li-ion batteries. A three-dimensional and nonisothermal numerical model of a PEMFC with a PCM cooling channel (PCC) is established in this study. The PCC is better than an air-cooling channel (ACC) in terms of reactant distribution and water removal. Its temperature at the interface of the gas diffusion layer and catalyst layer is lower, and the uniformity of temperature is better. The peak current and power density of the PCC are 4.60% and 5.14% higher than those of the ACC, respectively. Furthermore, the PCC does not increase parasitic power, unlike the ACC. In addition, owing to the high temperature near the outlet, the cooling effects of filling 1/3 PCM and filling 2/3 PCM near the outlet and filling of all PCM are investigated, which shows that the filling of 2/3 PCM provides a better cooling performance.
Boron and its alloys have long been explored as potential fuel and increasingly replace pure aluminum powder in high-energy formulations. The ignition and burning properties of boron can be improved by making boron alloys. In this study, an Mg–Al–B alloy was synthesized from magnesium, aluminum and boron powders in a 1:1:4 molar ratio by preheating to 600 °C for 30 min, followed by high-temperature sintering in a tube furnace. The effects of sintering temperature (700–1000 °C) and holding time (0.5–10 h) on the phase composition of mixed powders were studied. After the samples were cooled to room temperature, they were ground into powder. The phase composition, micromorphology and the bonding forms of elements of the synthesized samples were studied using XRD, SEM and XPS. The results show that each element exists in the form of simple substance in the alloy. The influence of the sintering temperature on the synthesis reaction of Mg0.5Al0.5B2 is very important, but holding time has little effect on it. With the increase of sintering temperature, the content of the Mg0.5Al0.5B2 phase gradually increases, and the phase content of residual metal gradually decreases. The phase and morphology analyses show that the optimum sintering temperature is 1000 °C with a minimum holding time of 0.5 h. It is expected to be used in gunpowder, propellant, explosives and pyrotechnics with improved characteristics.
Heat exchangers have a very wide range of applications in many industrial fields, so the rational design and the performance are to improve the heat exchanger energy efficiency and reduce the production cost of an important means. In this paper, the heat transfer mechanism of pulsation is revealed by simulating and analyzing the effects of three pulsation parameters: volumetric flow rate, pulsation frequency, and pulsation amplitude on the flow and heat transfer of a wavy-walled tube heat exchanger, with the study focusing on the instability behavior that affects the heat transfer mechanism. The results reveal that the combined heat transfer performance of the wavy-walled tube heat exchanger is about 8.2% higher than that of the straight-walled tube heat exchanger. The flow field of the heat exchanger is more fully developed under the pulsating flow field, and its performance evaluation coefficients (PECs) are all greater than 1. It is also found that with the increase in the volume flow rate Qv, the heat transfer enhancement coefficient and PEC first increase and then decrease, and reach the maximum value near Qv = 2.0 m3/h; with the increase in the amplitude A, the vortex and heat transfer enhancement coefficient inside the heat exchanger increase, but the integrated heat transfer performance of the heat exchanger is gradually weakened; with the increase in the frequency fT, the heat transfer enhancement coefficient and PEC first increase gradually, but the increase gradually decreases and levels off in the later stages, reaching a maximum value near fT = 0.5 Hz. Meanwhile, the field coefficients of the wavy-walled tube heat exchanger were analyzed and found to be much smaller than 1, with an order of magnitude of 10−4, and the results also showed that the field coefficients were inversely proportional to the volume flow rate and directly proportional to the amplitude of pulsation and that the field coefficients showed a tendency of increasing and then decreasing with the change of pulsation frequency and reached a maximum value near fT = 0.5 Hz. This work provides an important reference for current manufacturing industries to optimize heat exchanger sizing and develop efficient thermal management systems.