Gustav Burström

Dr. Gustav Burström


Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 January 2021 in Acta Neurochirurgica
Verified
Journal Article
Open access
PDF file
GBGustav Burström
Gustav Burström
OPOscar Persson
Oscar Persson
EEErik Edström
Erik Edström
AEAdrian Elmi-Terander
Adrian Elmi-Terander
Background: Conventional spinal navigation solutions have been criticized for having a negative impact on time in the operating room and workflow. AR navigation could potentially alleviate some of these concerns while retaining the benefits of navigated spine surgery. The objective of this study is to summarize the current evidence for using augmented reality (AR) navigation in spine surgery.Methods: We performed a systematic review to explore the current evidence for using AR navigation in spine surgery. PubMed and Web of Science were searched from database inception to November 27, 2020, for data on the AR navigation solutions; the reported efficacy of the systems; and their impact on workflow, radiation, and cost-benefit relationships.Results: In this systematic review, 28 studies were included in the final analysis. The main findings were superior workflow and non-inferior accuracy when comparing AR to free-hand (FH) or conventional surgical navigation techniques. A limited number of studies indicated decreased use of radiation. There were no studies reporting mortality, morbidity, or cost-benefit relationships.Conclusions: AR provides a meaningful addition to FH surgery and traditional navigation methods for spine surgery. However, the current evidence base is limited and prospective studies on clinical outcomes and cost-benefit relationships are needed.

27 August 2019 in Operative Neurosurgery
Verified
Journal Article
Open access
PDF file
EEErik Edström
Erik Edström
GBGustav Burström
Gustav Burström
RNRami Nachabe
Rami Nachabe
PGPaul Gerdhem
Paul Gerdhem
AEAdrian Elmi-Terander
Adrian Elmi-Terander
BACKGROUND: Treatment of several spine disorders requires placement of pedicle screws. Detailed 3-dimensional (3D) anatomic information facilitates this process and improves accuracy. OBJECTIVE: To present a workflow for a novel augmented-reality-based surgical navigation (ARSN) system installed in a hybrid operating room for anatomy visualization and instrument guidance during pedicle screw placement. METHODS: The workflow includes surgical exposure, imaging, automatic creation of a 3D model, and pedicle screw path planning for instrument guidance during surgery as well as the actual screw placement, spinal fixation, and wound closure and intraoperative verification of the treatment results. Special focus was given to process integration and minimization of overhead time. Efforts were made to manage staff radiation exposure avoiding the need for lead aprons. Time was kept throughout the procedure and subdivided to reflect key steps. The navigation workflow was validated in a trial with 20 cases requiring pedicle screw placement (13/20 scoliosis). RESULTS: Navigated interventions were performed with a median total time of 379 min per procedure (range 232-548 min for 4-24 implanted pedicle screws). The total procedure time was subdivided into surgical exposure (28%), cone beam computed tomography imaging and 3D segmentation (2%), software planning (6%), navigated surgery for screw placement (17%) and non-navigated instrumentation, wound closure, etc (47%). CONCLUSION: Intraoperative imaging and preparation for surgical navigation totaled 8% of the surgical time. Consequently, ARSN can routinely be used to perform highly accurate surgery potentially decreasing the risk for complications and revision surgery while minimizing radiation exposure to the staff.

11 January 2022 in Sensors
Verified
Journal Article
Open access
PDF file
HFHenrik Frisk
Henrik Frisk
ELEliza Lindqvist
Eliza Lindqvist
OPOscar Persson
Oscar Persson
JWJuliane Weinzierl
Juliane Weinzierl
LBLinda K. Bruetzel
Linda K. Bruetzel
AEAdrian Elmi-Terander
Adrian Elmi-Terander
Background: To investigate the accuracy of augmented reality (AR) navigation using the Magic Leap head mounted device (HMD), pedicle screws were minimally invasively placed in four spine phantoms. Methods: AR navigation provided by a combination of a conventional navigation system integrated with the Magic Leap head mounted device (AR-HMD) was used. Forty-eight screws were planned and inserted into Th11-L4 of the phantoms using the AR-HMD and navigated instruments. Postprocedural CT scans were used to grade the technical (deviation from the plan) and clinical (Gertzbein grade) accuracy of the screws. The time for each screw placement was recorded. Results: The mean deviation between navigation plan and screw position was 1.9 ± 0.7 mm (1.9 [0.3–4.1] mm) at the entry point and 1.4 ± 0.8 mm (1.2 [0.1–3.9] mm) at the screw tip. The angular deviation was 3.0 ± 1.4° (2.7 [0.4–6.2]°) and the mean time for screw placement was 130 ± 55 s (108 [58–437] s). The clinical accuracy was 94% according to the Gertzbein grading scale. Conclusion: The combination of an AR-HMD with a conventional navigation system for accurate minimally invasive screw placement is feasible and can exploit the benefits of AR in the perspective of the surgeon with the reliability of a conventional navigation system.

5 May 2020 in Scientific Reports
Verified
Journal Article
Open access
PDF file
GBGustav Burström
Gustav Burström
MBMarcin Balicki
Marcin Balicki
APAlexandru Patriciu
Alexandru Patriciu
SKSean Kyne
Sean Kyne
APAleksandra Popovic
Aleksandra Popovic
AEAdrian Elmi-Terander
Adrian Elmi-Terander
The combination of navigation and robotics in spine surgery has the potential to accurately identify and maintain bone entry position and planned trajectory. The goal of this study was to examine the feasibility, accuracy and efficacy of a new robot-guided system for semi-automated, minimally invasive, pedicle screw placement. A custom robotic arm was integrated into a hybrid operating room (OR) equipped with an augmented reality surgical navigation system (ARSN). The robot was mounted on the OR-table and used to assist in placing Jamshidi needles in 113 pedicles in four cadavers. The ARSN system was used for planning screw paths and directing the robot. The robot arm autonomously aligned with the planned screw trajectory, and the surgeon inserted the Jamshidi needle into the pedicle. Accuracy measurements were performed on verification cone beam computed tomographies with the planned paths superimposed. To provide a clinical grading according to the Gertzbein scale, pedicle screw diameters were simulated on the placed Jamshidi needles. A technical accuracy at bone entry point of 0.48 ± 0.44 mm and 0.68 ± 0.58 mm was achieved in the axial and sagittal views, respectively. The corresponding angular errors were 0.94 ± 0.83° and 0.87 ± 0.82°. The accuracy was statistically superior (p < 0.001) to ARSN without robotic assistance. Simulated pedicle screw grading resulted in a clinical accuracy of 100%. This study demonstrates that the use of a semi-automated surgical robot for pedicle screw placement provides an accuracy well above what is clinically acceptable.

31 July 2020 in Spine
Verified
Journal Article
Closed access
GBGustav Burström
Gustav Burström
RNRami Nachabe
Rami Nachabe
RHRobert Bsc Homan
Robert Bsc Homan
JHJurgen Msc Hoppenbrouwers
Jurgen Msc Hoppenbrouwers
RHRonald Msc Holthuizen
Ronald Msc Holthuizen
AEAdrian Elmi-Terander
Adrian Elmi-Terander
Study Design.: Observational study. Objective.: The aim of this study was to evaluate the accuracy of a new frameless reference marker system for patient tracking by analyzing the effect of vertebral position within the surgical field. Summary of Background Data.: Most modern navigation systems for spine surgery rely on a dynamic reference frame attached to a vertebra for tracking the patient. This solution has the drawback of being bulky and obstructing the surgical field, while requiring that the dynamic reference frame is moved between vertebras to maintain accuracy. Methods.: An augmented reality surgical navigation (ARSN) system with intraoperative cone beam computed tomography (CBCT) capability was installed in a hybrid operating room. The ARSN system used input from four video cameras for tracking adhesive skin markers placed around the surgical field. The frameless reference marker system was evaluated first in four human cadavers, and then in 20 patients undergoing navigated spine surgery. In each CBCT, the impact of vertebral position in the surgical field on technical accuracy was analyzed. The technical accuracy of the inserted pedicle devices was determined by measuring the distance between the planned position and the placed pedicle device, at the bone entry point. Results.: The overall mean technical accuracy was 1.65 ± 1.24 mm at the bone entry point (n = 366). There was no statistically significant difference in technical accuracy between levels within CBCTs (P ≥ 0.12 for all comparisons). Linear regressions showed that null- to negligible parts of the effect on technical accuracy could be explained by the number of absolute levels away from the index vertebrae (r 2 ≤ 0.007 for all, β ≤ 0.071 for all). Conclusion.: The frameless reference marker system based on adhesive skin markers is unobtrusive and affords the ARSN system a high accuracy throughout the navigated surgical field, independent of vertebral position. Level of Evidence: 3

2 October 2020 in European Radiology
Verified
Journal Article
Open access
PDF file
GBGustav Burström
Gustav Burström
PCPaulina Cewe
Paulina Cewe
ACAnastasios Charalampidis
Anastasios Charalampidis
RNRami Nachabe
Rami Nachabe
MSMichael Söderman
Michael Söderman
EEErik Edström
Erik Edström
Objectives: To test the hypothesis that intraoperative cone beam computed tomography (CBCT) using the Allura augmented reality surgical navigation (ARSN) system in a dedicated hybrid operating room (OR) matches computed tomography (CT) for identification of pedicle screw breach during spine surgery. Methods: Twenty patients treated with spinal fixation surgery (260 screws) underwent intraoperative CBCT as well as conventional postoperative CT scans (median 12 months after surgery) to identify and grade the degree of pedicle screw breach on both scan types, according to the Gertzbein grading scale. Blinded assessments were performed by three independent spine surgeons and the CT served as the standard of reference. Screws graded as Gertzbein 0 or 1 were considered clinically accurate while grades 2 or 3 were considered inaccurate. Sensitivity, specificity, and negative predictive value were the primary metrics of diagnostic performance. Results: For this patient group, the negative predictive value of an intraoperative CBCT to rule out pedicle screw breach was 99.6% (CI 97.75–99.99%). Among 10 screws graded as inaccurate on CT, 9 were graded as such on the CBCT, giving a sensitivity of 90.0% (CI 55.5–99.75%). Among the 250 screws graded as accurate on CT, 244 were graded as such on the CBCT, giving a specificity of 97.6% (CI 94.85–99.11%). Conclusions: CBCT, performed intraoperatively with the Allura ARSN system, is comparable and non-inferior to a conventional postoperative CT scan for ruling out misplaced pedicle screws in spinal deformity cases, eliminating the need for a postoperative CT. Key Points: • Intraoperative cone beam computed tomography (CT) using the Allura ARSN is comparable with conventional CT for ruling out pedicle screw breaches after spinal fixation surgery. • Intraoperative cone beam computed tomography can be used to assess need for revisions of pedicle screws making routine postoperative CT scans unnecessary. • Using cone beam computed tomography, the specificity was 97.6% and the sensitivity was 90% for detecting pedicle screw breaches and the negative predictive value for ruling out a pedicle screw breach was 99.6%.