Heart failure (HF) and left ventricular hypertrophy (LVH) are linked to fibroblast growth factor 23 (FGF23). This study aims to analyze whether FGF23 can predict postoperative outcomes in unselected left ventricular assist device (LVAD) candidates. Methods: We conducted a prospective observational study that included 27 patients (25 HeartMate3 and 2 HeartMateII) with a median follow-up of 30 months. We measured preoperative FGF23 plasma levels and computed the HeartMateII risk score (HMRS), the HeartMate3 risk score (HM3RS) and the EuroSCOREII with respect to postoperative mortality, as well as the Michigan right heart failure risk score (MRHFS), the Euromacs RHF risk score (EURORHFS), the CRITT score with respect to RHF prediction and the kidney failure risk equation (KFRE) with respect to kidney failure. Multivariate logistic regression and receiver operating characteristic (ROC) analyses were performed. Results: In the multivariate logistic regression, preoperative FGF23 level was found to be a predictor of postoperative RHF (OR: 1.37, 95-CI: 0.78–2.38; p = 0.031), mortality (OR: 1.10, 95%-CI: 0.90–1.60; p = 0.025) and the need for postoperative dialysis (OR: 1.09, 95%-CI: 0.91–1.44; p = 0.032). In the ROC analysis, FGF23 as a predictor of post-LVAD RHF had an area under the curve (AUC) of 0.81. Conclusions: FGF23 improves the prediction of clinically significant patient outcomes—such as need for dialysis, RHF and mortality—after HM3 and HMII implantation, as adding FGF23 to established risk scores increased their predictive value.
Introduction: Despite the improvements in standardized cardiopulmonary resuscitation, survival remains low, mainly due to initial myocardial dysfunction and hemodynamic instability. Our goal was to compare the efficacy of two left ventricular assist devices on resuscitation and hemodynamic supply in a porcine model of ventricular fibrillation (VF) cardiac arrest. Methods: Seventeen anaesthetized pigs had 12 min of untreated VF followed by 6 min of chest compression and boluses of epinephrine. Next, a first defibrillation was attempted and pigs were randomized to any of the three groups: control (n = 5), implantation of an percutaneous left ventricular assist device (Impella, n = 5) or extracorporeal membrane oxygenation (ECMO, n = 7). Hemodynamic and myocardial functions were evaluated invasively at baseline, at return of spontaneous circulation (ROSC), after 10–30–60–120–240 min post-resuscitation. The primary endpoint was the rate of ROSC. Results: Only one of 5 pigs in the control group, 5 of 5 pigs in the Impella group, and 5 of 7 pigs in the ECMO group had ROSC (p < 0.05). Left ventricular ejection fraction at 240 min post-resuscitation was 37.5 ± 6.2% in the ECMO group vs. 23 ± 3% in the Impella group (p = 0.06). No significant difference in hemodynamic parameters was observed between the two ventricular assist devices. Conclusion: Early mechanical circulatory support appeared to improve resuscitation rates in a shockable rhythm model of cardiac arrest. This approach appears promising and should be further evaluated.