Husneni Mukhtar

Dr. Husneni Mukhtar


Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 August 2024 in Heliyon
Verified
Journal Article
Open access
HKHifsa Khurshid
Hifsa Khurshid
BMBashar Mohammed
Bashar Mohammed
Naraindas BheelNaraindas Bheel
Naraindas Bheel
Willy CahyadiWilly Cahyadi
Willy Cahyadi
HMHusneni Mukhtar
Husneni Mukhtar
Currently, the field of structural health monitoring (SHM) is focused on investigating non-destructive evaluation techniques for the identification of damages in concrete structures. Magnetic sensing has particularly gained attention among the innovative non-destructive evaluation techniques. Recently, the embedded magnetic shape memory alloy (MSMA) wire has been introduced for the evaluation of cracks in concrete components through magnetic sensing techniques while providing reinforcement as well. However, the available research in this regard is very scarce. This study has focused on the analyses of parameters affecting the magnetic sensing capability of embedded MSMA wire for crack detection in concrete beams. The response surface methodology (RSM) and artificial neural network (ANN) models have been used to analyse the magnetic sensing parameters for the first time. The models were trained using the experimental data obtained through literature. The models aimed to predict the alteration in magnetic flux created by a concrete beam that has a 1 mm wide embedded MSMA wire after experiencing a fracture or crack. The results showed that the change in magnetic flux was affected by the position of the wire and the position of the crack with respect to the position of the magnet in the concrete beam. RSM optimisation results showed that maximum change in magnetic flux was obtained when the wire was placed at a depth of 17.5 mm from the top surface of the concrete beam, and a crack was present at an axial distance of 8.50 mm from the permanent magnet. The change in magnetic flux was 9.50 % considering the aforementioned parameters. However, the ANN prediction results showed that the optimal wire and crack position were 10 mm and 1.1 mm, respectively. The results suggested that a larger beam requires a larger diameter of MSMA wire or multiple sensors and magnets for crack detection in concrete beams.

5 February 2024 in International Journal of Electrical and Electronics Research
Verified
Journal Article
Open access
PDF file
SNSifa Nurpadillah
Sifa Nurpadillah
WCWilly Anugrah Cahyadi
Willy Anugrah Cahyadi
HMHusneni Mukhtar
Husneni Mukhtar
KSKusnahadi Susanto
Kusnahadi Susanto
AIAkhmad Fauzi Ikhsan
Akhmad Fauzi Ikhsan
ANAgung Ihwan Nurdin
Agung Ihwan Nurdin
Geo-electrical resistivity methods are widely used in various fields and have significant applications in scientific and practical research. Despite the widespread use of resistivity methods, current injection is a critical step in the process of resistivity methods, and the quality of current injection significantly impacts the accuracy of the resistivity measurements. One primary challenge is optimizing current injection techniques to enhance resistivity methods. The developed current injector model for the resistivity meter instrument enhances performance by increasing the voltage source to 400 Volts, extending measurement coverage. It provides three injection current options, 0.5A, 0.8A, and 1A, for efficient accumulator use, considering electrode distances and estimating earth resistance using Contact Resistance Measurement (CRM) to estimate the earth resistance. CRM mode ensures proper electrode connection before injection, thus improving measurement efficiency. The embedded TTGO LoRa ESP32 SX1276 facilitates wireless communication over 1.5 km, addressing challenges in remote and internet-limited areas. The model demonstrates reliability, validity, and durability in CRM mode and current injection measurement. Regarding reliability, we determine the relative error of the model by carrying out measurements repeatedly. In lab-scale testing, the average Relative Error in CRM mode is 0.65%, and in earth resistance measurement testing, it is 1.58%. These relative errors are below the 2% maximum error applied in the “Supersting”, a commercial resistivity instrument. The model's validity is defined by comparing the model with the measuring instrument; we have absolute error. In lab scale testing, the average Absolute Error in CRM mode is 3.08%, and in earth resistance measurement testing, it is 3.73%. The model's durability is tested by injecting current for a minute. After one minute of current injection, the power resistor component's temperature is stable at 30°C.

17 April 2021
Verified
Book Chapter
Closed access
PDF file
AKAhmad Akbar Khatami
Ahmad Akbar Khatami
HMHusneni Mukhtar
Husneni Mukhtar
DRDien Rahmawati
Dien Rahmawati

5 February 2024 in International Journal of Electrical and Electronics Research
Verified
Journal Article
Open access
SNSifa Nurpadillah
Sifa Nurpadillah
WCWilly Anugrah Cahyadi
Willy Anugrah Cahyadi
HMHusneni Mukhtar
Husneni Mukhtar
KSKusnahadi Susanto
Kusnahadi Susanto
AIAkhmad Fauzi Ikhsan
Akhmad Fauzi Ikhsan
ANAgung Ihwan Nurdin
Agung Ihwan Nurdin
Geo-electrical resistivity methods are widely used in various fields and have significant applications in scientific and practical research. Despite the widespread use of resistivity methods, current injection is a critical step in the process of resistivity methods, and the quality of current injection significantly impacts the accuracy of the resistivity measurements. One primary challenge is optimizing current injection techniques to enhance resistivity methods. The developed current injector model for the resistivity meter instrument enhances performance by increasing the voltage source to 400 Volts, extending measurement coverage. It provides three injection current options, 0.5A, 0.8A, and 1A, for efficient accumulator use, considering electrode distances and estimating earth resistance using Contact Resistance Measurement (CRM) to estimate the earth resistance. CRM mode ensures proper electrode connection before injection, thus improving measurement efficiency. The embedded TTGO LoRa ESP32 SX1276 facilitates wireless communication over 1.5 km, addressing challenges in remote and internet-limited areas. The model demonstrates reliability, validity, and durability in CRM mode and current injection measurement. Regarding reliability, we determine the relative error of the model by carrying out measurements repeatedly. In lab-scale testing, the average Relative Error in CRM mode is 0.65%, and in earth resistance measurement testing, it is 1.58%. These relative errors are below the 2% maximum error applied in the “Supersting”, a commercial resistivity instrument. The model's validity is defined by comparing the model with the measuring instrument; we have absolute error. In lab scale testing, the average Absolute Error in CRM mode is 3.08%, and in earth resistance measurement testing, it is 3.73%. The model's durability is tested by injecting current for a minute. After one minute of current injection, the power resistor component's temperature is stable at 30°C.

17 April 2021
Verified
Book Chapter
Closed access
PDF file
GGGhifari Indra Gunawan
Ghifari Indra Gunawan
DSDesri Kristina Silalahi
Desri Kristina Silalahi
HMHusneni Mukhtar
Husneni Mukhtar
DBDandi Trianta Barus
Dandi Trianta Barus
DRDien Rahmawati
Dien Rahmawati

3 August 2025 in Engineering Science Letter
Verified
Journal Article
Open access
HMHusneni Mukhtar
Husneni Mukhtar
MZMuhammad Mugni Zaelani
Muhammad Mugni Zaelani
MNMuhammad Rafy Nasrullah
Muhammad Rafy Nasrullah
HSHesty Susanti
Hesty Susanti
Blood glucose measurement is critical to diabetes management and prevents chronic complications such as neuropathy, nephropathy, and retinopathy. However, current methods are invasive, uncomfortable, and costly. Although several non-invasive approaches have been explored, no commercially available device offers a simple, affordable, and user-friendly solution for non-invasive blood glucose estimation, particularly one suitable for self-measurement outside clinical settings. This underscores the need for practical and inclusive alternatives. This study aimed to develop and evaluate a blood glucose estimation device using infrared LEDs to measure light transmittance through the fingertip. The research was conducted in two stages: initial testing using glucose solutions with varying concentrations (0.02, 0.06, 0.10, and 0.20 g/ml) and added red dye (0.05, 0.10, and 0.15 ml) to validate the sensor's response, followed by direct validation on human fingers against commercial blood glucose test strip readings. The results showed a strong positive correlation between sensor output and glucose levels, with a Pearson correlation coefficient of r = 0.995. Using a regression-based calibration model, the system achieved a mean absolute error (MAE) of 1.63 mg/dL, and a root mean square error (RMSE) of 1.72 mg/dL. Cross-validation, such as Bland-Altman analysis and Clarke Error Grid, was conducted to verify model robustness. These preliminary results suggest that the developed system holds strong potential as a simple, affordable, and non-invasive tool for blood glucose self-monitoring, especially in resource-limited settings. However, further validation on larger, more diverse populations is necessary.