Javier González-Rosalén

Mr. Javier González-Rosalén

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 July 2021 in Diagnostics
Verified
Journal Article
Open access
PDF file
JGJavier González-Rosalén
Javier González-Rosalén
Josep C. Benítez-MartínezJosep C. Benítez-Martínez
Josep C. Benítez-Martínez
Francesc Medina-MirapeixFrancesc Medina-Mirapeix
Francesc Medina-Mirapeix
APAlba Cuerda-Del Pino
Alba Cuerda-Del Pino
ACAntonio Cervelló
Antonio Cervelló
Rodrigo Martín San AgustínRodrigo Martín San Agustín
Rodrigo Martín San Agustín
Hand held dynamometers (HHDs) are the most used method to measure strength in clinical sitting. There are two methods to realize the assessment: pull and push. The purpose of the present study was to evaluate the intra- and inter-rater reliability of a new measurement modality for pull HHD and to compare the inter-rater reliability and agreement of the measurements. Forty healthy subjects were evaluated by two assessors with different body composition and manual strength. Fifteen isometric tests were performed in two sessions with a one-week interval between them. Reliability was examined using the intra-class correlation (ICC) and the standard error of measurement (SEM). Agreement between raters was examined using paired t-tests. Intra- and inter-rater reliability for the tests performed with the pull HHD showed excellent values, with ICCs ranging from 0.991 to 0.998. For tests with values higher than 200 N, push HHD showed greater differences between raters than pull HHD. Pull HHD attached to the examiner’s body is a method with excellent reliability to measure isometric strength and showed better agreement between examiners, especially for those tests that showed high levels of strength. Pull HHD is a new alternative to perform isometric tests with less rater dependence.

29 October 2021 in Diagnostics
Verified
Journal Article
Open access
PDF file
JGJavier González-Rosalén
Javier González-Rosalén
Francesc Medina-MirapeixFrancesc Medina-Mirapeix
Francesc Medina-Mirapeix
APAlba Cuerda-Del Pino
Alba Cuerda-Del Pino
Noemí Moreno SeguraNoemí Moreno Segura
Noemí Moreno Segura
MGMariano Gacto-Sánchez
Mariano Gacto-Sánchez
Rodrigo Martín San AgustínRodrigo Martín San Agustín
Rodrigo Martín San Agustín
Quantifying training variables of a physical exercise modality is essential for an appropriate dosage. In training with elastic bands, time under tension (TUT) and force represent the duration and intensity of this force-training modality. The aims of this study were to evaluate the degree of compliance to TUT prescription for three different scenarios of two exercises and the comparison of the force values obtained versus the estimate values. A total of 29 healthy volunteers were evaluated in a clinical environment under controlled conditions in 3 different scenarios (different velocities or ROMs) of both shoulder abduction and knee extension in 2 sets of 10 repetitions per scenario within a single session. Concentric and isometric phases showed a higher degree of compliance for their TUTs than the eccentric phase TUTs for all scenarios of both exercises, whereas the degree of compliance was higher for the total TUT than for the phases’ TUTs. Additionally, the eccentric phase showed a general tendency to develop for longer time periods than prescribed, whilst the fast scenario showed a higher degree of compliance for isometric phase TUTs and total TUTs than the extant two scenarios in both exercises. On the other hand, the force of the elastic bands tends to be overestimated according to the estimates of the manufacturers. These findings, both those related to the degree of compliance with TUTs and the force analysis, can be used by physiotherapists and other exercise professionals as a reference to achieve a good dosage of routine exercises with elastic bands.