Josep C. Benítez-Martínez

Prof. Josep C. Benítez-Martínez

Universitat de Valencia
orcid

Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 April 2008 in Journal of Orthopaedic & Sports Physical Therapy
Verified
Journal Article
Closed access
César Fernandez-de-las-PeñasCésar Fernandez-de-las-Peñas
César Fernandez-de-las-Peñas
JAJoan C. Albert-Sanchís
Joan C. Albert-Sanchís
MBMiguel Buil
Miguel Buil
Josep C. Benítez-MartínezJosep C. Benítez-Martínez
Josep C. Benítez-Martínez
Francisco Alburquerque-SendínFrancisco Alburquerque-Sendín
Francisco Alburquerque-Sendín
Case-control study. To analyze the differences in muscle size and shape of cervical multifidus between patients with bilateral chronic neck pain and healthy subjects. Researchers have demonstrated atrophy of lumbar multifidus in patients presenting with low back pain; however, there are only few published reports on cervical multifidus muscle size in individuals with chronic neck pain. Bilateral ultrasound images of multifidus muscle from the third to sixth cervical vertebrae (C3 to C6) were taken in 20 women with bilateral chronic neck pain and 20 healthy women. Cross-sectional area (CSA [cm2]) and muscle shape ratio (ratio between lateral [Lat] and anterior-posterior [AP] dimensions, [Lat/AP]) were measured without knowledge of group assignment. Two separate 3-way (4 x 2 x 2) mixed-model analyses of variance (ANOVAs) with cervical level (C3 to C6) and side (right, left) as within-subject factors and group (patient, control) as the between-subject factor, were used to evaluate differences in CSA and muscle shape ratio between groups, sides, and cervical levels. The ANOVA for CSA indicated a significant effect for cervical level (F = 6.81, P<.001) and group (F = 20.27, P<.001), but not for side (F = 1.26, P = .36). There were no significant interactions among the variables (P>.5). Post hoc analysis showed that the CSA of the C3 multifidus was smaller than the CSA of the C4 (P = .025), C5 (P<.001) or C6 (P<.01) multifidus. There was no significant difference between C4, C5, and C6 multifidus CSA (P>.05). The patients with neck pain had a smaller CSA of the cervical multifidus at all levels compared to controls (P<.001). The ANOVA for muscle shape ratio indicated a significant effect for level (F = 7.84, P<.001) and group (F = 12.501, P<.001), but not for side (F = 0.654, P = .58). There was a significant interaction between level and group (F = 3.651, P = .01). Patients had a wider ovoid shape (greater values in muscle shape ratio) of the C3 (P<.001) and C6 (P<.01) cervical multifidus compared to controls. Further, the C4 multifidus had a smaller shape ratio compared to C6 (P<.001), but was not significantly different than the shape ratio of the C3 and C5 (P>.05) multifidus. Females with bilateral chronic neck pain had generalized smaller CSA of the cervical multifidus muscles compared to healthy females.

1 February 2016 in Manual Therapy
Verified
Journal Article
Closed access
JRJ. Rubio-Ochoa
J. Rubio-Ochoa
Josep C. Benítez-MartínezJosep C. Benítez-Martínez
Josep C. Benítez-Martínez
ELE. Lluch
E. Lluch
SSS. Santacruz-Zaragozá
S. Santacruz-Zaragozá
PGP. Gómez-Contreras
P. Gómez-Contreras
CCC.E. Cook
C.E. Cook

1 October 2014 in Journal of Bodywork and Movement Therapies
Verified
Journal Article
Closed access
GEGemma Victoria Espí-López
Gemma Victoria Espí-López
AGAntonia Gómez-Conesa
Antonia Gómez-Conesa
Anna Arnal-GómezAnna Arnal-Gómez
Anna Arnal-Gómez
Josep C. Benítez-MartínezJosep C. Benítez-Martínez
Josep C. Benítez-Martínez
Angel Oliva Pacual-VacaAngel Oliva Pacual-Vaca
Angel Oliva Pacual-Vaca
Cleofás Rodríguez BlancoCleofás Rodríguez Blanco
Cleofás Rodríguez Blanco

11 December 2023 in Experimental Gerontology
Verified
Journal Article
Open access
PGPedro Gargallo
Pedro Gargallo
ETEva Tamayo
Eva Tamayo
PMPablo Jiménez Martínez
Pablo Jiménez Martínez
ÁTÁlvaro Juesas Torres
Álvaro Juesas Torres
Jose Casaña GranellJose Casaña Granell
Jose Casaña Granell
Juan C ColadoJuan C Colado
Juan C Colado
This study aimed to explore the effects of 20 weeks of multicomponent or power training with elastic bands (EBs) on metabolic and inflammatory blood parameters, body composition, anthropometry, and physical function in older women with metabolic syndrome (MS). Ninety participants were randomly assigned to a multicomponent (MCG; n = 30), power (PG; n = 30), or a control group (CG; n = 30). The MCG performed balance, slow-speed strength, and aerobic training, twice per week. The PG completed a high-speed resistance training program twice per week, composed of three to four sets of ten repetitions of six overall body exercises at a perceived rating of effort for the first repetition of 3-4 on the OMNI-Resistance Exercise Scale EB. MS-related variables (glucose, triglycerides, and waist circumference) and cardiometabolic risk factors (high-density lipoprotein [HDL], glycosylated hemoglobin, total cholesterol, low-density lipoprotein cholesterol [LDL], C-reactive protein, and anthropometric profile) were assessed. Physical function was evaluated through balance, strength, and mobility tests. An analysis of variance revealed that both training groups similarly improved most glycemic and lipidic profile parameters (p ≤ 0.006; d ≥ 0.46), body composition and anthropometry (p < 0.001; d ≥ 0.41), and physical function (p ≤ 0.005; d ≥ 0.69). Opposed to the PG, the MCG improved balance (p < 0.001; d = 0.96) and decreased the inflammatory status by downregulating C-reactive protein (p = 0.003; d = 0.47). On the other hand, the PG exhibited improvements in handgrip strength (p = 0.006; d = 0.48), while the MCG did not. Therefore, multicomponent and power training with EBs are plausible strategies for improving the cardiometabolic health status and physical function in older women with MS.

17 May 2018 in Foot & Ankle International
Verified
Journal Article
Closed access
TFTOMAS FERNANDEZ-RODRIGUEZ
TOMAS FERNANDEZ-RODRIGUEZ
ÁFÁlvaro Fernández-Rolle
Álvaro Fernández-Rolle
STSebastián Truyols-Domínguez
Sebastián Truyols-Domínguez
Josep C. Benítez-MartínezJosep C. Benítez-Martínez
Josep C. Benítez-Martínez
Jose Casaña GranellJose Casaña Granell
Jose Casaña Granell
Chronic plantar heel pain (CPHP) is a common condition with high prevalence rates and a projected cost of treatment of US$192 to US$376 million. There are several therapeutic approaches and there is increased interest in treatments aimed at the regeneration of tissues with poor healing potential. Our purpose was to investigate the effectiveness of ultrasound-guided percutaneous needle electrolysis in chronic plantar heel pain. A total of 73 patients with a clinical and ultrasonographic diagnosis of plantar heel pain unrelated to systemic inflammatory disease who had not received any other treatment in the previous 6 months on the affected foot were randomly allocated to receive either ultrasound-guided percutaneous needle electrolysis of the fascia (experimental group, n = 39) or placebo puncture (control group, n = 34). The primary outcome was pain scored with an 11-point numeric pain rating scale (0 = no pain, 10 = maximum pain). Secondary outcomes were function and disability measured by the 21-item activities of daily living subscale of the Foot and Ankle Ability Measure questionnaire, and fascia thickness measured by ultrasound. Outcomes were measured at 1, 12, and 24 weeks. The mixed-model analysis of covariance observed significant group x time interactions from all variables: pain in numeric pain rating scale (P < .001), FAAM Activities of Daily Living Subscale scale (P < .002), and ultrasonographic measures of the plantar heel (P < .002). Patients in the experimental group had better results posttreatment at 12 and 24 weeks compared with the control group. With chronic plantar heel pain, ultrasound-guided percutaneous needle electrolysis improved pain and function. This treatment may also decrease fascia thickness. Level I, randomized controlled trial.

8 July 2021 in Diagnostics
Verified
Journal Article
Open access
PDF file
JGJavier González-Rosalén
Javier González-Rosalén
Josep C. Benítez-MartínezJosep C. Benítez-Martínez
Josep C. Benítez-Martínez
Francesc Medina-MirapeixFrancesc Medina-Mirapeix
Francesc Medina-Mirapeix
APAlba Cuerda-Del Pino
Alba Cuerda-Del Pino
ACAntonio Cervelló
Antonio Cervelló
Rodrigo Martín San AgustínRodrigo Martín San Agustín
Rodrigo Martín San Agustín
Hand held dynamometers (HHDs) are the most used method to measure strength in clinical sitting. There are two methods to realize the assessment: pull and push. The purpose of the present study was to evaluate the intra- and inter-rater reliability of a new measurement modality for pull HHD and to compare the inter-rater reliability and agreement of the measurements. Forty healthy subjects were evaluated by two assessors with different body composition and manual strength. Fifteen isometric tests were performed in two sessions with a one-week interval between them. Reliability was examined using the intra-class correlation (ICC) and the standard error of measurement (SEM). Agreement between raters was examined using paired t-tests. Intra- and inter-rater reliability for the tests performed with the pull HHD showed excellent values, with ICCs ranging from 0.991 to 0.998. For tests with values higher than 200 N, push HHD showed greater differences between raters than pull HHD. Pull HHD attached to the examiner’s body is a method with excellent reliability to measure isometric strength and showed better agreement between examiners, especially for those tests that showed high levels of strength. Pull HHD is a new alternative to perform isometric tests with less rater dependence.