Huiqun Wang

Dr. Huiqun Wang

orcid

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 April 2018 in Atmospheric Chemistry and Physics
Verified
Journal Article
Open access
PDF file
PLPieternel F. Levelt
Pieternel F. Levelt
JJJoanna Joiner
Joanna Joiner
JTJohanna Tamminen
Johanna Tamminen
JVJ. Pepijn Veefkind
J. Pepijn Veefkind
PBPawan K. Bhartia
Pawan K. Bhartia
KWKrzysztof Wargan
Krzysztof Wargan
This overview paper highlights the successes of the Ozone Monitoring Instrument (OMI) on board the Aura satellite spanning a period of nearly 14 years. Data from OMI has been used in a wide range of applications and research resulting in many new findings. Due to its unprecedented spatial resolution, in combination with daily global coverage, OMI plays a unique role in measuring trace gases important for the ozone layer, air quality, and climate change. With the operational very fast delivery (VFD; direct readout) and near real-time (NRT) availability of the data, OMI also plays an important role in the development of operational services in the atmospheric chemistry domain.

5 January 2015 in Atmospheric Measurement Techniques
Verified
Journal Article
Open access
GAG. González Abad
G. González Abad
XLXiong Liu
Xiong Liu
KCK. Chance
K. Chance
HWHuiqun Wang
Huiqun Wang
TKT. P. Kurosu
T. P. Kurosu
RSR. Suleiman
R. Suleiman
We present and discuss the Smithsonian Astrophysical Observatory (SAO) formaldehyde (H2CO) retrieval algorithm for the Ozone Monitoring Instrument (OMI) which is the operational retrieval for NASA OMI H2CO. The version of the algorithm described here includes relevant changes with respect to the operational one, including differences in the reference spectra for H2CO, the fit of O2–O2 collisional complex, updates in the high-resolution solar reference spectrum, the use of a model reference sector over the remote Pacific Ocean to normalize the retrievals, an updated air mass factor (AMF) calculation scheme, and the inclusion of scattering weights and vertical H2CO profile in the level 2 products. The setup of the retrieval is discussed in detail. We compare the results of the updated retrieval with the results from the previous SAO H2CO retrieval. The improvement in the slant column fit increases the temporal stability of the retrieval and slightly reduces the noise. The change in the AMF calculation has increased the AMFs by 20%, mainly due to the consideration of the radiative cloud fraction. Typical values for retrieved vertical columns are between 4 × 1015 and 4 × 1016 molecules cm−2, with typical fitting uncertainties ranging between 45 and 100%. In high-concentration regions the errors are usually reduced to 30%. The detection limit is estimated at 1 × 1016 molecules cm−2.

25 November 2014 in Atmospheric Measurement Techniques
Verified
Journal Article
Open access
CMC. Chan Miller
C. Chan Miller
GAG. Gonzalez Abad
G. Gonzalez Abad
HWHuiqun Wang
Huiqun Wang
XLXiong Liu
Xiong Liu
TKT. Kurosu
T. Kurosu
KCK. Chance
K. Chance
We present an algorithm for the retrieval of glyoxal from backscattered solar radiation, and apply it to spectra measured by the Ozone Monitoring Instrument (OMI). The algorithm is based on direct spectrum fitting, and adopts a two-step fitting routine to account for liquid water absorption. Previous studies have shown that glyoxal retrieval algorithms are highly sensitive to the position of the spectral fit window. This dependence was systematically tested on real and simulated OMI spectra. We find that a combination of errors resulting from uncertainties in reference cross sections and spectral features associated with the Ring effect are consistent with the fit-window dependence observed in real spectra. This implies an optimal fitting window of 435–461 nm, consistent with previous satellite glyoxal retrievals. The results from the retrieval of simulated spectra also support previous findings that have suggested that glyoxal is sensitive to NO2 cross-section temperature. The retrieval window limits of the liquid water retrieval are also tested. A retrieval window 385–470 nm reduces interference with strong spectral features associated with sand. We show that cross-track dependent offsets (stripes) present in OMI can be corrected using offsets derived from retrieved slant columns over the Sahara, and apply the correction to OMI data. Average glyoxal columns are on average lower than those of previous studies likely owing to the choice of reference sector for offset correction. OMI VCDs (vertical column densities)are lower compared to other satellites over the tropics and Asia during the monsoon season, suggesting that the new retrieval is less sensitive to water vapour abundance. Consequently we do not see significant glyoxal enhancements over tropical oceans. OMI-derived glyoxal-to-formaldehyde ratios over biogenic and anthropogenic source regions are consistent with surface observations.

15 May 2023 in Earth and Space Science
Verified
Journal Article
Open access
CNCaroline R. Nowlan
Caroline R. Nowlan
GAGonzalo González Abad
Gonzalo González Abad
HKHyeong‐Ahn Kwon
Hyeong‐Ahn Kwon
ZAZolal Ayazpour
Zolal Ayazpour
CMChristopher Chan Miller
Christopher Chan Miller
KSKang Sun
Kang Sun
We describe new publicly available, multi‐year formaldehyde (HCHO) data records from the Ozone Mapping and Profiler Suite (OMPS) nadir mapper (NM) instruments on the Suomi NPP and NOAA‐20 satellites. The OMPS‐NM instruments measure backscattered UV light over the globe once per day, with spatial resolutions close to nadir of 50 × 50 km2 (OMPS/Suomi‐NPP) and 17 × 17 km2 or 12 × 17 km2 (OMPS/NOAA‐20). After a preliminary instrument line shape and wavelength calibration using on‐orbit observations, we use the backscatter measurements in a direct spectral fit of radiances, in combination with a nadir reference spectrum collected over a clean area, to determine slant columns of HCHO. The slant columns are converted to vertical columns using air mass factors (AMFs) derived through scene‐by‐scene radiative transfer calculations. Finally, a correction is applied to account for background HCHO in the reference spectrum, as well as any remaining high‐latitude biases. We investigate the consistency of the OMPS products from Suomi NPP and NOAA‐20 using long‐term monthly means over 12 geographic regions, and also compare the products with publicly available TROPOMI HCHO observations. OMPS/Suomi‐NPP and OMPS/NOAA‐20 monthly mean HCHO vertical columns are highly consistent (r = 0.98), with low proportional (2%) and offset (2 × 1014 molecules cm−2) biases. OMPS HCHO monthly means are also well‐correlated with those from TROPOMI (r = 0.92), although they are consistently 10% ± 16% larger in polluted regions (columns >8 × 1015 molecules cm−2). These differences result primarily from differences in AMFs.

30 June 2014 in Atmospheric Measurement Techniques
Verified
Journal Article
Open access
HWHuiqun Wang
Huiqun Wang
XLXiong Liu
Xiong Liu
KCK. Chance
K. Chance
GAG. González Abad
G. González Abad
CMC. Chan Miller
C. Chan Miller
There are distinct spectral features of water vapor in the wavelength range covered by the Ozone Monitoring Instrument (OMI) visible channel. Although these features are much weaker than those at longer wavelengths, they can be exploited to retrieve useful information about water vapor. They have an advantage in that their small optical depth leads to fairly simple interpretation as measurements of the total water vapor column density. We have used the Smithsonian Astrophysical Observatory (SAO) OMI operational retrieval algorithm to derive the slant column density (SCD) of water vapor using the 430–480 nm spectral region after extensive optimization. We convert from SCD to vertical column density (VCD) using the air mass factor (AMF), which is calculated using look-up tables of scattering weights and assimilated water vapor profiles. Our Level 2 product includes not only water vapor VCD but also the associated scattering weights and AMF. In the tropics, our standard water vapor product has a median SCD of 1.3 × 1023 molecules cm−2 and a median relative uncertainty of about 11%, about a factor of 2 better than that from a similar OMI algorithm that uses a narrower retrieval window. The corresponding median VCD is about 1.2 × 1023 molecules cm−2. We have examined the sensitivities of SCD and AMF to various parameters and compared our results with those from the GlobVapour product, the Moderate Resolution Imaging Spectroradiometer (MODIS) and the Aerosol Robotic NETwork (AERONET).

27 September 2019 in Atmospheric Measurement Techniques
Verified
Journal Article
Open access
PDF file
HWHuiqun Wang
Huiqun Wang
ASAmir Hossein Souri
Amir Hossein Souri
GAGonzalo González Abad
Gonzalo González Abad
XLXiong Liu
Xiong Liu
KCKelly Chance
Kelly Chance
Total column water vapor (TCWV) is important for the weather and climate. TCWV is derived from the Ozone Monitoring Instrument (OMI) visible spectra using the version 4.0 retrieval algorithm developed at the Smithsonian Astrophysical Observatory. The algorithm uses a retrieval window between 432.0 and 466.5 nm and includes updates to reference spectra and water vapor profiles. The retrieval window optimization results from the trade-offs among competing factors. The OMI product is characterized by comparing against commonly used reference datasets – global positioning system (GPS) network data over land and Special Sensor Microwave Imager/Sounder (SSMIS) data over the oceans. We examine how cloud fraction and cloud-top pressure affect the comparisons. The results lead us to recommend filtering OMI data with a cloud fraction less than f=0.05–0.25 and cloud-top pressure greater than 750 mb (or stricter), in addition to the data quality flag, fitting root mean square (RMS) and TCWV range check. Over land, for f=0.05, the overall mean of OMI–GPS is 0.32 mm with a standard deviation (σ) of 5.2 mm; the smallest bias occurs when TCWV = 10–20 mm, and the best regression line corresponds to f=0.25. Over the oceans, for f=0.05, the overall mean of OMI–SSMIS is 0.4 mm (1.1 mm) with σ=6.5 mm (6.8 mm) for January (July); the smallest bias occurs when TCWV = 20–30 mm, and the best regression line corresponds to f=0.15. For both land and the oceans, the difference between OMI and the reference datasets is relatively large when TCWV is less than 10 mm. The bias for the version 4.0 OMI TCWV is much smaller than that for version 3.0. As test applications of the version 4.0 OMI TCWV over a range of spatial and temporal scales, we find prominent signals of the patterns associated with El Niño and La Niña, the high humidity associated with a corn sweat event, and the strong moisture band of an atmospheric river (AR). A data assimilation experiment demonstrates that the OMI data can help improve the Weather Research and Forecasting (WRF) model skill at simulating the structure and intensity of the AR and the precipitation at the AR landfall.