Marcin Habrych

Dr. Marcin Habrych

Wroclaw University of Science and Technology
orcid

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 May 2022 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
MWMarek Wasowski
Marek Wasowski
Marcin HabrychMarcin Habrych
Marcin Habrych
Tomasz SikorskiTomasz Sikorski
Tomasz Sikorski
PKPaweł Kostyła
Paweł Kostyła
MJMariusz Jurczyk
Mariusz Jurczyk
MGMarcin Golemo
Marcin Golemo
The article presents the cross-sectional results of analyzes of authentic conducted disturbances introduced into public power networks by various types of loads installed at end users. The foundation for the research was a set of 260 identified cases of Power Line Communication (PLC) transmission disturbances based on the Open Smart Grid Protocol (OSGP) technology, which were recorded in the urban network of the distribution system operator covering over 400,000 smart meters. The paper presents a quantitative assessment of the share of loads that most often cause problems with transmission efficiency. Moreover, a qualitative assessment of the detected disturbance cases was carried out in terms of conditions relating to the structure of the power grid and real transmission levels and disturbance levels. The authors made a pioneering analysis in the so-called “communication path” where the PLC communication disturbance was identified, i.e., from the installation point of the PLC concentrator to the metering point where the energy meter, with which the connection was lost, was installed.

26 October 2017 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
Marcin HabrychMarcin Habrych
Marcin Habrych
Grzegorz WiśniewskiGrzegorz Wiśniewski
Grzegorz Wiśniewski
BMBogdan Miedziński
Bogdan Miedziński
ALAleksander Lisowiec
Aleksander Lisowiec
ZFZbigniew Fjalkowski
Zbigniew Fjalkowski
The article presents and discusses the results of analysis and experimental studies of the metrological characteristics of Rogowski coils made in HDI PCB (High Density Interconnect Printed Circuit Boards) technology. The purpose of the research and analysis was to determine the possibility of their use in the metering units of automated electrical power systems. Particular emphasis placed on the formation of the resonant characteristics as well as to provide suitable resistance to external interfering electromagnetic fields. This allows, inter alia, the use of Rogowski coils for detection of interfering transmissions PLC high-frequency conductive currents. Basing on the obtained results, conclusions and recommendations for practice are formulated.

15 November 2021 in Energies
Verified
Journal Article
Open access
PDF file
WKWojciech Kurpiel
Wojciech Kurpiel
PDPrzemysław Deja
Przemysław Deja
BPBartosz Polnik
Bartosz Polnik
MSMarcin Skóra
Marcin Skóra
BMBogdan Miedziński
Bogdan Miedziński
PFPrzemyslaw Falkowski-Gilski
Przemyslaw Falkowski-Gilski
To use lithium-iron-phosphate battery packs in the supply systems of any electric mining equipment and/or machines, the required conditions of work safety must be met. This applies in particular to coal mines endangered by fire and/or explosion. To meet the spark-safety conditions, the cells (together with the battery management system—BMS) must be isolated from the influence of the environment, and therefore placed in special fire-tight housings. This significantly degrades the heat dissipation, thus affecting the operating conditions of the cell-packs. Therefore, their usage without the so-called BMS is not recommended, as shown in the authors’ preliminary research. In practice, various BMS are used, most often with the so-called passive balancing. However, their application in mines is uncertain, due to the effect of heating under operation. When it comes to active BMS, they usually possess a quite complex structure and hence, are relatively expensive. Therefore, the authors conducted research for two specially developed active and one commercial passive BMS cooperating with selected lithium-iron-phosphate (LiFePO4) batteries when used in a suspended mining vehicle type PCA-1. The tests were carried out under environmental temperatures ranging from +5 °C to +60 °C. The effect of mismatching (12.5% to 37.5% of total cells number) of the cell parameters on the temperature distribution and voltage fading at the terminals of individual cells was checked. As a result of the investigations, the practical usefulness of the developed active BMS was determined, enabling the extension of the lithium-iron-phosphate battery life under onerous mine conditions, for a single recharge, which is a novelty. On the basis of the obtained results, appropriate practical conclusions were formulated.

2 February 2021 in Energies
Verified
Journal Article
Open access
PDF file
Marek WasowskiMarek Wasowski
Marek Wasowski
Tomasz SikorskiTomasz Sikorski
Tomasz Sikorski
Grzegorz WiśniewskiGrzegorz Wiśniewski
Grzegorz Wiśniewski
PKPaweł Kostyła
Paweł Kostyła
Jaroslaw SzymandaJaroslaw Szymanda
Jaroslaw Szymanda
MJMariusz Jurczyk
Mariusz Jurczyk
Knowledge of the conducted emissions in the frequency range 2–150 kHz contains some gaps related to the impact of the harmonics in the supply voltage on the nature of these emissions. It can be noticed that the conducted emissions from non-sinusoidal power supplies have not been studied sufficiently, and that the impact of this distortion may be greater than the generally known results of emission tests carried out under standardized test conditions. This paper is aimed at investigating experimental cases of the influence of supply voltage waveform distortion on non-intentional emission in the range 2–150 kHz and the efficiency of power line communication based on selected PRIME (PoweRline Intelligent Metering Evolution) power line communication (PLC) technology. A series of experimental laboratory studies were investigated, representing the operation of the investigated PLC system with different types of end-user equipment (LED—Light Emitting Diode, CFL—Compact Fluorescent Lamp, induction motor with frequency converter) working under a distorted supply voltage condition obtained by the programmable power supply for different scenarios of the admissible harmonics contribution in the range 0–2 kHz. The scenarios included limits defined in standards EN 50160 and IEC 61000-4-13. The researchers used spectral analysis with a notation to emission limits, compatibility levels, and mains signalling, as well as statistics of the PLC communication. The obtained results provide important conclusions, which may be applied both in the development of the design of the appliances in question and the higher frequency emission testing methods.

13 May 2014 in Elektronika ir Elektrotechnika
Verified
Journal Article
Closed access
PDF file
DPD. Pyda
D. Pyda
Marcin HabrychMarcin Habrych
Marcin Habrych
KRK. Rutecki
K. Rutecki
BMBogdan Miedziński
Bogdan Miedziński
Although the PLC technology is increasingly used mainly in low voltage networks, causes of interference of signal transmission have not been, as yet, sufficiently explained. It is very important for the wider use of this technology in practice. The paper presents and discusses the results of simulation analysis of transmission efficiency for narrow band PRIME standard obtained for specially developed for this purpose simulation model of the real low voltage network. This model allows both the mapping of the network parameters in the desired range as well as the modelling of physical phenomena occurring in it that may practically affect the narrow-band transmission quality. On the basis of the results the suitable conclusions for practical applications have been formulated. DOI: http://dx.doi.org/10.5755/j01.eee.20.5.7101

1 July 2015
Verified
Conference Paper
Closed access
Marcin HabrychMarcin Habrych
Marcin Habrych
Grzegorz WiśniewskiGrzegorz Wiśniewski
Grzegorz Wiśniewski
BMBogdan Miedziński
Bogdan Miedziński
ALAleksander Lisowiec
Aleksander Lisowiec
The paper discusses the possibility of obtaining the required parameters of Rogowski coils when apply of printed circuit board high density technology. Selected results of investigations are presented and examples of Rogowski coils for use in electrical power system protections are given.