Three-dimensional (3D) printing has become broadly available and can be utilized to customize clamping mechanisms in biomechanical experiments. This report will describe our experience using 3D printed clamps to mount soft tissues from different anatomical regions. The feasibility and potential limitations of the technology will be discussed. Tissues were sourced in a fresh condition, including human skin, ligaments and tendons. Standardized clamps and fixtures were 3D printed and used to mount specimens. Inquasi-statictensile tests combined with digital image correlation andfatiguetrials we characterized the applicability of the clamping technique. Scanning electron microscopy was utilized to evaluate the specimens to assess the integrity of the extracellular matrix following the mechanical tests. 3D printed clamps showed no signs of clamping-related failure during thequasi-statictests, and intact extracellular matrix was found in the clamping area, at the transition clamping area and the central area from where the strain data was obtained. In thefatiguetests, material slippage was low, allowing for cyclic tests beyond 105cycles. Comparison to other clamping techniques yields that 3D printed clamps ease and expedite specimen handling, are highly adaptable to specimen geometries and ideal for high-standardization and high-throughput experiments in soft tissue biomechanics.
1 January 2014 in Journal of the Mechanical Behavior of Biomedical Materials
Treating proximal humerus fractures can be challenging because of large metaphyseal defects that conceal anatomical landmarks. In such cases, medial cortical support with, for example, calcar screws, is mandatory. Nevertheless, varus dislocations and implant failures in patients with impaired bone quality persist. Thus, the need for effective treatment of these patients exists. Hybrid double plate osteosynthesis was introduced as an alternative, yielding similar results as calcar screws. However, a biomechanical comparison of the stability of these two techniques is pending. Cadaveric humeral specimens were treated with plate osteosynthesis and calcar screws (group 1, n = 9) or hybrid double plate osteosynthesis (group 2, n = 9) using a proximal humerus fracture model with a two-part fracture. Displacement, stiffness, failure mode, and ultimate load were examined biomechanically in a cyclic compressive-loading scenario. Although the hybrid double plate osteosynthesis (group 2) tended to confer higher stiffnesses than the medial support screws at higher cycles (group 1), this trend was below the level of significance. The displacement revealed non-significantly lower values for group 1 as compared with group 2 for cycles 50 and 2000, but at 5000 cycles, group 2 offered non-significantly lower displacement values than group 1. The ultimate load tended to be non-significantly higher in the hybrid double plate osteosynthesis group (group 2: 1342±369 N, group 1: 855±408 N). Both groups yielded similar failure rates, with the majority of failures in group 2 being gap closures (n = 8), whereas those in group 1 being plate dislocations (n = 4). The use of an additive plate osteosynthesis in the region of the bicipital groove may be a potential alternative to the previously-established method of using calcar screws. The biomechanical data obtained in this study suggests that hybrid double plate osteosynthesis is as rigid and robust as calcar screws.
To provide a close-to-reality simulation model, such as for improved surgery planning, this model has to be experimentally verified. The present article describes the use of a 3D laser vibrometer for determining modal parameters of human pelvic bones that can be used for verifying a finite elements model. Compared to previously used sensors, such as acceleration sensors or strain gauges, the laser vibrometric procedure used here is a non-contact and non-interacting measuring method that allows a high density of measuring points and measurement in a global coordinate system. Relevant modal parameters were extracted from the measured data and provided for verifying the model. The use of the 3D laser vibrometer allowed the establishment of a process chain for experimental examination of the pelvic bones that was optimized with respect to time and effort involved. The transfer functions determined feature good signal quality. Furthermore, a comparison of the results obtained from pairs of pelvic bones showed that repeatable measurements can be obtained with the method used.