Ana-Maria Iordache

Dr. Ana-Maria Iordache

Optospintronics Department, National Institute for Research and Development for Optoelectronics—INOE 2000, 077125 Magurele, Romania
orcid

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 June 2014 in Materials Science and Engineering: C
Verified
Journal Article
Closed access
MBMarcela-Elisabeta Barbinta-Patrascu
Marcela-Elisabeta Barbinta-Patrascu
CUCamelia Ungureanu
Camelia Ungureanu
SIStefan-Marian Iordache
Stefan-Marian Iordache
AIAna-Maria Iordache
Ana-Maria Iordache
IȘIoana-Raluca Șuică-Bunghez
Ioana-Raluca Șuică-Bunghez
ISIoan Stamatin
Ioan Stamatin

17 August 2022 in Diagnostics
Verified
Journal Article
Open access
PDF file
Gatin EduardGatin Eduard
Gatin Eduard
SIStefan-Marian Iordache
Stefan-Marian Iordache
EMElena Matei
Elena Matei
CLCatalin Romeo Luculescu
Catalin Romeo Luculescu
AIAna-Maria Iordache
Ana-Maria Iordache
RIRoxana Romanita Ilici
Roxana Romanita Ilici
(1) Background: The treatment of dental cavities and restoration of tooth shape requires specialized materials with specific clinical properties, including being easy to model, light-cured, having a natural color, reduced shrinkage, a hardness similar to hydroxyapatite, and no leakage. The dimensional stability of resin composite materials is affected by polymerization shrinkage, degree of conversion (number of π carbon bonds converted into σ ones), thermal contraction and expansion, and interactions with an aqueous environment. (2) Methods: The materials used in our investigation were two composite resins with similar polymer matrices, but different filler (micro/nano filler). To evaluate the properties of samples, we employed the pycnometer technique (pycnometer from Paul Marienfeld Gmbh, Lauda-Königshofen, Germany), RAMAN spectroscopy technique (MiniRam Equipment from B&W Tek Inc., Plainsboro Township, NJ, USA; 785 nm laser source), SEM and EDX (FEI Inspect S.). (3) Results: The size of the filler plays an important role in the polymerization: for the pycnometric results, the larger particle filler (Sample 1) seems to undergo a rapid polymerization during the 45 s curing, while the nanoparticle filer (Sample 2) needs additional curing time to fully polymerize. This is related to a much larger porosity, as proved by SEM images. The lower degree of conversion, as obtained by Raman spectroscopy, in the same geometry means that the same volume is probed for both samples, but Sample 1 is more porous, which means less amount of polymer is probed for Sample 1. (4) Conclusions: For the two composites, we obtained a degree of conversion of 59% for Sample 1 and 93% for Sample 2, after 45 s of curing.

19 January 2022 in Diagnostics
Verified
Journal Article
Open access
PDF file
RBRoxana Elena Bohîlțea
Roxana Elena Bohîlțea
VDVlad Dima
Vlad Dima
IDIonita Ducu
Ionita Ducu
AIAna-Maria Iordache
Ana-Maria Iordache
BSBianca-Margareta Salmen
Bianca-Margareta Salmen
Radu VladareanuRadu Vladareanu
Radu Vladareanu
Umbilical cord abnormalities are not rare, and are often associated with structural or chromosomal abnormalities, fetal intrauterine growth restriction, and poor pregnancy outcomes; the latter can be a result of prematurity, placentation deficiency or, implicitly, an increased index of cesarean delivery due to the presence of fetal distress, higher admission to neonatal intensive care, and increased prenatal mortality rates. Even if the incidence of velamentous insertion, vasa praevia and umbilical knots is low, these pathologies increase the fetal morbidity and mortality prenatally and intrapartum. There is a vast heterogeneity among societies’ guidelines regarding the umbilical cord examination. We consider the mandatory introduction of placental cord insertion examination in the first and second trimester to practice guidelines for fetal ultrasound scans. Moreover, during the mid-trimester scan, we recommend a transvaginal ultrasound and color Doppler assessment of the internal cervical os for low-lying placentas, marginal or velamentous cord insertion, and the evaluation of umbilical cord entanglement between the insertion sites whenever it is incidentally found. Based on the pathological description and the neonatal outcome reported for each entity, we conclude our descriptive review by establishing a new, clinically relevant classification of these umbilical cord anomalies.

18 September 2020 in Nanomaterials
Verified
Journal Article
Open access
PDF file
MEMihail Elisa
Mihail Elisa
RSRaluca Constantina Stefan
Raluca Constantina Stefan
CVCristina Vasiliu
Cristina Vasiliu
SIStefan-Marian Iordache
Stefan-Marian Iordache
AIAna-Maria Iordache
Ana-Maria Iordache
VKVictor Kuncser
Victor Kuncser
This work investigates the structural, magnetic and magneto-optical properties of a new zinc phosphate-tellurite glass belonging to the 45ZnO-10Al2O3-40P2O5-5TeO2 system. The glass was prepared by a wet method of processing the starting reagents followed by suitable melting–stirring–quenching–annealing steps. Specific parameters such as density, average molecular mass, molar volume, oxygen packaging density, refractive index, molar refractivity, electronic polarizability, reflection loss, optical transmission, band gap and optical basicity have been reported together with thermal, magnetic and magneto-optical characteristics. Absorption bands appear in the blue and red visible region, while over 600 nm the glass becomes more transparent. FTIR and Raman spectra evidenced phosphate-tellurite vibration modes proving the P2O5 and TeO2 network forming role. Magnetic measurements reveal the diamagnetic character of the Te-doped glass with an additional weak ferromagnetic signal, specific to diluted ferromagnetic oxides. Positive Faraday rotation angle with monotonous decreasing value at increasing wavelength was evidenced from magneto-optical measurements. The final product is a composite material comprising of a non-crystalline vitreous phase and Te-based nanoclusters accompanied by oxygen vacancies. The metallic-like Te colloids are responsible for the dark reddish color of the glass whereas the accompanying oxygen vacancies might be responsible for the weak ferromagnetic signal persisting up to room temperature.

7 December 2021 in Medicina
Verified
Journal Article
Open access
PDF file
Tiberiu Augustin GeorgescuTiberiu Augustin Georgescu
Tiberiu Augustin Georgescu
RBRoxana Elena Bohiltea
Roxana Elena Bohiltea
OMOctavian Munteanu
Octavian Munteanu
FFFlorentina Ligia Furtunescu
Florentina Ligia Furtunescu
AGAntonia Carmen Georgescu
Antonia Carmen Georgescu
AIAna-Maria Iordache
Ana-Maria Iordache
Neuroendocrine neoplasms (NENs) are particularly rare in all sites of the gynecological tract and include a variety of neoplasms with variable prognosis, dependent on histologic subtype and site of origin. Following the expert consensus proposal of the International Agency for Research on Cancer (IARC), the approach in the latest World Health Organization (WHO) Classification System of the Female Genital Tumours is to use the same terminology for NENs at all body sites. The main concept of this novel classification framework is to align it to all other body sites and make a clear distinction between well-differentiated neuroendocrine tumors (NETs) and poorly differentiated neuroendocrine carcinomas (NECs). The previous WHO Classification System of the Female Genital Tumours featured more or less the same principle, but used the terms ‘low-grade neuroendocrine tumor’ and ‘high-grade neuroendocrine carcinoma’. Regardless of the terminology used, each of these two main categories include two distinct morphological subtypes: NETs are represented by typical and atypical carcinoid and NEC are represented by small cell neuroendocrine carcinoma (SCNEC) and large cell neuroendocrine carcinoma (LCNEC). High-grade NECs, especially small cell neuroendocrine carcinoma tends to be more frequent in the uterine cervix, followed by the endometrium, while low-grade NETs usually occur in the ovary. NENs of the vulva, vagina and fallopian tube are exceptionally rare, with scattered case reports in the scientific literature.

26 October 2022 in Diagnostics
Verified
Journal Article
Open access
PDF file
AZAlexei Zubarev
Alexei Zubarev
MCMarina Cuzminschi
Marina Cuzminschi
AIAna-Maria Iordache
Ana-Maria Iordache
SIStefan-Marian Iordache
Stefan-Marian Iordache
CRConstantin Rizea
Constantin Rizea
CGCarmen Giuglea
Carmen Giuglea
In this work, we study the sensing properties of multi-layer graphene combined with pyrrole in order to elaborate low-cost, high-sensitive material for cortisol detection. Graphene nanoplatelets and pyrrole were dispersed in a solution containing 1M HNO3 by using a powerful ultrasound probe for 10 min, then centrifuged for 30 min at 4000 rpm; polymerization was performed by cyclic voltammetry. The graphene–pyrrole composite was tested to ultra-low levels of cortisol in artificial saliva, consistent to the levels excreted in human salivary samples. The composite was further investigated by Raman spectroscopy and we modeled the interaction between the sensitive layer and cortisol using MarvinBeans software. It shows a good sensitivity for salivary values of cortisol cyclic voltammetry being able to detect a level down to 0.5 ng/mL cortisol.