Anas Ben Achour

Anas Ben Achour


Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 February 2024 in Frontiers in Bioengineering and Biotechnology
Verified
Journal Article
Open access
AAAnas Ben Achour
Anas Ben Achour
FAFlorian Apfeld
Florian Apfeld
GLGünter Lauer
Günter Lauer
CBChristian Bräuer
Christian Bräuer
HLHenry Leonhardt
Henry Leonhardt
TSTom Alexander Schröder
Tom Alexander Schröder
Purpose: The aim of this study is to develop a test bench, which integrates different complexity levels and enables in that way a flexible and dynamic testing for mid and long term intervals as well as testing of maximum loads till implant failure of different osteosynthesis systems on the mandible.Material and Methods: For this purpose, an analysis of the state of the art regarding existing test benches was combined with interviews of clinical experts to acquire a list of requirements. Based on these requirements a design for a modular test bench was developed. During the implementation of the test stand, functional tests were continuously carried out and improvements made. Depending on the level of complexity, the test bench can be used either as an incorporated variant or as a standalone solution. In order to verify the performance and the degree of fulfilment of the requirements of these two variants of the test bench, preliminary studies were carried out for all levels of complexity. In these preliminary studies, commercially available osteosynthesis and reconstruction plates were investigated for their biomechanical behaviour and compared with data from the literature.Results: In total, fourteen test runs were performed for the different levels of complexity. Firstly, five test runs were executed to test the simplified load scenario in the incorporated variant of the test bench. High forces could be transmitted without failure of the miniplates. Secondly a quasi-static test scenario was examined using the incorporated variant with simplified load insertion. Five experiments with a number of cycles between 40,896 and 100,000 cycles were carried out. In one case the quasi-static testing resulted in a fracture of the tested reconstruction plate with a failure mode similar to the clinical observations of failure. The last four test runs were carried out using the standalone variant of the test bench simulating complex load patterns via the insertion of forces through imitated muscles. During the test runs joint forces were measured and the amplitude and vector of the resulting joint forces were calculated for both temporomandibular joints. Differences in the force transmission depending on the implant system in comparison to the zero sample could be observed.Conclusion: The presented modular test bench showed to be applicable for examination of the biomechanical behavior of the mandible. It is characterized by the adjustability of the complexity regarding the load patterns and enables the subsequent integration of further sensor technologies. Follow-up studies are necessary to further qualify and optimize the test bench.

Verified
Journal Article
Open access
PDF file
TSTom Alexander Schröder
Tom Alexander Schröder
MMMartin Maiwald
Martin Maiwald
ARAxel Reinicke
Axel Reinicke
UTUwe Teicher
Uwe Teicher
ASAndré Seidel
André Seidel
AAAnas Ben Achour
Anas Ben Achour
Cleft lip and palate belong to the most frequent craniofacial anomalies. Secondary osteoplasty is usually performed between 7 and 11 years with the closure of the osseus defect by autologous bone. Due to widespread occurrence of the defect in conjunction with its social significance due to possible esthetic impairments, the outcome of treatment is of substantial interest. The success of the treatment is determined by the precise rebuilding of the dental arch using autologous bone from the iliac crest. A detailed analysis of retrospective data disclosed a lack of essential and structured information to identify success factors for fast regeneration and specify the treatment. Moreover, according to the current status, no comparable process monitoring is possible during osteoplasty due to the lack of sensory systems. Therefore, a holistic approach was developed to determine the parameters for a successful treatment via the incorporation of patient data, the treatment sequences and sensor data gained by an attachable sensor module into a developed Dental Tech Space (DTS). This approach enables heterogeneous data sets to be linked inside of DTS, archiving and analysis, and is also for future considerations of respective patient-specific treatment plans.

2 September 2021 in Biomechanics
Verified
Journal Article
Open access
PDF file
AAAnas Ben Achour
Anas Ben Achour
CPCarola Petto
Carola Petto
HMHeike Meissner
Heike Meissner
AMAnita Mostofa
Anita Mostofa
UTUwe Teicher
Uwe Teicher
GLGünter Lauer
Günter Lauer
Background: The aim is to evaluate methods to quantify the interstitial splitting force and thermal load input of self-tapping and self-drilling osteosynthesis screws. Methods: A specialized modular test bench was developed to measure the induced splitting force of self-drilling and self-tapping osteosynthesis screws using porcine mandibular bone. In addition, a fundamentally new approach to measure the temperature near the contact zone of osteosynthesis screws (fiber-optic sensor in the axis of the screw) was established. Results: The self-drilling screw type induces a splitting force of about 200 N in the surrounding tissue, so that microdamage of the bone and increased resorption can be assumed. Even pre-drilling induces a short-time force into the tissue, which is comparable to the splitting force of the self-tapping screw. The temperature increase in the screw is clearly higher compared to the temperature increase in the surrounding tissue, but no significant difference in temperature between the two screw types could be measured. Based on the measured temperatures of both screw types, the temperature increase in the contact zone is considered critical. Complications during the screwing process caused by the manual tool guidance resulted in numerous breakages of the fiber-optic sensors. Conclusions: The developed methods provide additional insight regarding the thermomechanical load input of self-drilling and self-tapping screws. However, based upon the optical fiber breakages, additional refinement of this technique may still be required.