Carola Petto

Mrs. Carola Petto


Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 December 2020 in Molecules
Verified
Journal Article
Open access
PDF file
KWKatarzyna Walczak
Katarzyna Walczak
GSGeorg Schierz
Georg Schierz
SBSabine Basche
Sabine Basche
CPCarola Petto
Carola Petto
KBKlaus Boening
Klaus Boening
Mieszko WieckiewiczMieszko Wieckiewicz
Mieszko Wieckiewicz
Chitosan (CS) and its derivatives show antimicrobial properties. This is of interest in preventing and treating denture stomatitis, which can be caused by fungi. Therefore, the aim of this study was the development of a novel antifungal denture base material by modifying polymethyl methacrylate (PMMA) with CS-salt and characterizing its antifungal and surface properties in vitro. For this purpose, the antifungal effect of chitosan-hydrochloride (CS-HCl) or chitosan-glutamate (CS-G) as solutions in different concentrations was determined. To obtain modified PMMA resin specimens, the CS-salts were added to the PMMA before polymerization. The roughness of these specimens was measured by contact profilometry. For the evaluation of the antifungal properties of the CS-salt modified resins, a C. albicans biofilm assay on the specimens was performed. As solutions, both the CS-G and CS-HCl-salt had an antifungal effect and inhibited C. albicans growth in a dose-dependent manner. In contrast, CS-salt modified PMMA resins showed no significant reduced C. albicans biofilm formation. Furthermore, the addition of CS-salts to PMMA significantly increased the surface roughness of the specimens. This study shows that despite the antifungal effect of CS-salts in solution, a modification of PMMA resin with these CS-salts does not improve the antifungal properties of PMMA denture base material.

9 November 2019 in Materials
Verified
Journal Article
Open access
PDF file
AAAnas Ben Achour
Anas Ben Achour
CPCarola Petto
Carola Petto
HMHeike Meissner
Heike Meissner
DHDominik Hipp
Dominik Hipp
ANAndreas Nestler
Andreas Nestler
UTUwe Teicher
Uwe Teicher
Bone drill chips that are collected during implant site preparation can be reused as autologous bone-grafting material for alveolar ridge augmentation. This study characterized five market-leading implant drill sets regarding their geometric properties and ability to produce vital bone chips. The drill geometry of each tool of five commercial implant drill sets was characterized while using optical profile projector devices and SEM. Bone chips were collected during the in vitro preparation of porcine jaw bone with the various drill sets. Produced bone chip masses were measured. The bone chips were cultured in vitro and the number of outgrown cells was determined and measurand for vitality. Furthermore, the thrust force and cutting torque were recorded to examine the mechanical loads of the manual drilling process. The tool geometry and set configuration of one out of five implant drill sets appears to be superior regarding chip mass, vitality, and thrust force. It could be proven that there is a correlation between vitality and thrust force. The thrust force is influenced by the cutting behavior of the tool, which in turn depends on the geometry of the tool. The tool geometry has an influence on the vitality of the augmentation material due to this relationship.

1 April 2017 in Journal of Cranio-Maxillofacial Surgery
Verified
Journal Article
Closed access
MMMaya Marewski
Maya Marewski
CPCarola Petto
Carola Petto
MSMatthias Schneider
Matthias Schneider
WHWinfried Harzer
Winfried Harzer

2 September 2021 in Biomechanics
Verified
Journal Article
Open access
PDF file
AAAnas Ben Achour
Anas Ben Achour
CPCarola Petto
Carola Petto
HMHeike Meissner
Heike Meissner
AMAnita Mostofa
Anita Mostofa
UTUwe Teicher
Uwe Teicher
GLGünter Lauer
Günter Lauer
Background: The aim is to evaluate methods to quantify the interstitial splitting force and thermal load input of self-tapping and self-drilling osteosynthesis screws. Methods: A specialized modular test bench was developed to measure the induced splitting force of self-drilling and self-tapping osteosynthesis screws using porcine mandibular bone. In addition, a fundamentally new approach to measure the temperature near the contact zone of osteosynthesis screws (fiber-optic sensor in the axis of the screw) was established. Results: The self-drilling screw type induces a splitting force of about 200 N in the surrounding tissue, so that microdamage of the bone and increased resorption can be assumed. Even pre-drilling induces a short-time force into the tissue, which is comparable to the splitting force of the self-tapping screw. The temperature increase in the screw is clearly higher compared to the temperature increase in the surrounding tissue, but no significant difference in temperature between the two screw types could be measured. Based on the measured temperatures of both screw types, the temperature increase in the contact zone is considered critical. Complications during the screwing process caused by the manual tool guidance resulted in numerous breakages of the fiber-optic sensors. Conclusions: The developed methods provide additional insight regarding the thermomechanical load input of self-drilling and self-tapping screws. However, based upon the optical fiber breakages, additional refinement of this technique may still be required.