peijun zhong

Dr. peijun zhong


Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 August 2022 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
PZpeijun zhong
peijun zhong
JSJianjun Sun
Jianjun Sun
LQLifeng Qu
Lifeng Qu
PYPan Yu
Pan Yu
XZXiaoming Zha
Xiaoming Zha
The wide-bandwidth grid impedance measurement is a vital way in the resonance and stability analysis of the grid-tied system. However, the grid inevitably suffers from some nonideal conditions, such as voltage unbalance, frequency deviation, harmonics, and interharmonics, which has not been fully considered and well handled in grid impedance measurement using pseudorandom binary sequences. To address this challenge, a three-stage interpolation-based measurement method for grid impedance measurement is presented in this letter. The proposed method adopts the cubic spline interpolation to reconstruct the sampled signal and use the Hanning-window-based interpolated fast Fourier transform (FFT) to remove some undesired components to deal with the spectral leakage caused by the FFT. Simulation and hardware-in-the-loop experimental results are presented to demonstrate the performance of the proposed method.

22 April 2020 in IEEE Journal of Emerging and Selected Topics in Power Electronics
Verified
Journal Article
Closed access
PZpeijun zhong
peijun zhong
JSJianjun Sun
Jianjun Sun
ZTZhen Tian
Zhen Tian
MHmeng huang
meng huang
PYPan Yu
Pan Yu
XZXiaoming Zha
Xiaoming Zha
The impedance of inverter and grid is to determine the stability of grid-connected inverter systems. Therefore, it is of great importance to obtain accurate grid impedance and inverter impedance. However, the previous studies on impedance measurement are easily subject to background harmonics and grid frequency deviation, which brings to nonunique identification and inaccurate extraction of current or voltage perturbations. In this article, an improved impedance measurement method is investigated for the grid-connected inverter systems. First, a novel selection principle of frequency for injected perturbation is proposed to avoid the impact of background harmonics on impedance measurement. Moreover, a two-stage series multiple-complex coefficient filter (TSMCCF) is also proposed to accurately extract these perturbations considering system may subject to harmonics and grid frequency deviation. Compared with the conventional MCCF, the proposed TSMCCF improves the dynamic performance and accuracy of impedance measurement without increasing the complexity. It is worth noting that the proposed method is not affected by background harmonics and grid frequency deviation, and could be applied in both three-phase and single-phase systems for impedance measurement. To validate the effectiveness and feasibility of the proposed impedance measurement method, real-time digital simulation results are presented based on the RT-LAB platform.

8 September 2021 in IEEE Transactions on Power Systems
Verified
Journal Article
Closed access
PYPan Yu
Pan Yu
ZTZhen Tian
Zhen Tian
XZXiaoming Zha
Xiaoming Zha
JSJianjun Sun
Jianjun Sun
PZpeijun zhong
peijun zhong
MHmeng huang
meng huang
As the crucial interface of renewable energy integration, the grid-tied inverter is a complicated system with a multi-timescale feature, containing both fast dynamics and slow dynamics that determine the system stability. However, previous researches on stability analysis mainly focus on the slow dynamics without considering the impact of fast dynamics, which may bring to inaccurate stability prediction. In this paper, the impact of fast dynamics on stability is investigated for grid-tied inverter from a physical perspective. Considering the dynamics of the current control loop and network, a two degrees-of-freedom oscillator model is firstly established to extract the fast dynamics separately. The damping torque analysis is then applied to analyze the impact of the extracted fast dynamics on the damping and spring coefficients of slow dynamics. Moreover, based on the fast dynamic analysis, a novel reduced-order model is proposed with the consideration of the dominant characteristics of fast dynamics, which improves the model accuracy without increasing the complexity. Eventually, both numerical evaluations and experiments are performed to validate the proposed analysis method.

27 October 2021 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
PZpeijun zhong
peijun zhong
JSJianjun Sun
Jianjun Sun
ZTZhen Tian
Zhen Tian
PYPan Yu
Pan Yu
XZXiaoming Zha
Xiaoming Zha
The wide bandwidth impedance of grid and inverter are the critical parameters for small-signal stability analysis and control optimization of grid-tied inverter systems. The impedance measurement is an effective way to obtain the grid and inverter impedance by injecting a series of perturbations into the measured system. However, previous studies fail to fully consider the adverse grid voltage conditions; including harmonics, unbalance, frequency deviation, voltage sag, and phase jump; which may bring errors to the measured impedance. In this article, a cascaded delayed signal cancellation (CDSC)-based method is proposed to accurately obtain the impedance of the measured system under adverse grid voltage conditions. The proposed CDSC-based method is mainly composed of the perturbation extraction module (PEM) and frequency adaptive module (FAM). Different CDSC blocks are applied to implement the PEM and FAM to extract the injected perturbations adaptively, under various adverse grid voltage conditions. Simulation and hardware-in-the-loop experiment results are presented to validate the effectiveness and feasibility of the proposed impedance measurement method.

15 February 2022 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
PYPan Yu
Pan Yu
XZXiaoming Zha
Xiaoming Zha
ZTZhen Tian
Zhen Tian
PZpeijun zhong
peijun zhong
JSJianjun Sun
Jianjun Sun
MHmeng huang
meng huang
Phase–locked loop (PLL) is commonly used for the grid-connected voltage-source converter (VSC) to synchronize with the grid. Under weak grid conditions, it has been found that the frequency-dependent characteristic of the network impedance inherently introduces a positive feedback loop into PLL. Previous studies focused on the PLL analysis intuitively believe that the positive feedback loop will deteriorate the dynamic performance of the PLL. However, this conclusion is not rigorous since only the dynamic of the PLL is considered and the theoretical analysis is insufficiency to reveal the influence of the positive feedback loop on system stability. In this paper, the impact of the frequency-dependent network on VSC stability is quantified in terms of the overall system based on the damping torque analysis. It is found that the influence of the positive feedback loop on stability depends on the parameters of the PLL and the damping of the dominant eigenvalues. Besides, an angular frequency feedback scheme is proposed to eliminate the adverse effect of the frequency-dependent network and enhance the stability of the VSC under weak grid conditions. Time-domain numerical simulations and reduced-scale experiments are performed to validate the effectiveness of the proposed scheme.

15 May 2023 in IEEE Transactions on Circuits and Systems II: Express Briefs
Verified
Journal Article
Closed access
PZpeijun zhong
peijun zhong
JSJianjun Sun
Jianjun Sun
PYPan Yu
Pan Yu
YLYi Liu
Yi Liu
XZXiaoming Zha
Xiaoming Zha
Impedance measurement unit (IMU) with injection of broadband perturbations is widely used to obtain grid and converter impedance. The accuracy of measured impedance and the power quality of the measured system rely on the amplitude control of the injected perturbations. However, the accuracy of output perturbation of IMU is lack of attention especially around the fundamental frequency of the measured system. In this brief, a three-phase DC-AC type IMU is introduced and the mechanism and solution of inaccurate perturbation output of the IMU is study. First, the DC-AC type IMU with PR current controllers, DC voltage controller and phase locked loop (PLL) is introduced. Next, the mechanism of inaccurate perturbation output is analysis, which is caused by the introduction of DC voltage ripple. Then, improved DC voltage control solutions with notch filter or delay filter are proposed to achieve the accurate control of single-frequency and multi-frequency perturbation current respectively. Finally, control hardware-in-the-loop experiment results are given to demonstrate and verify the effectiveness and feasibility of the proposed method.