Yi Liu

Yi Liu

Auto-generated profile, based on publicly available information

Yi Liu

School of Electrical Engineering and Automation, Wuhan University, Wuhan, China

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 May 2023 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
MZMingshuo Zhu
Mingshuo Zhu
YLYi Liu
Yi Liu
MHmeng huang
meng huang
ZLZifan Li
Zifan Li
XZXiaoming Zha
Xiaoming Zha
The reliability of dc link capacitors is closely related to the operational safety of the whole power electronic system. To meet the application requirements, it is usually necessary to use a series or parallel structure of multiple capacitors to increase the capacity and withstand voltage, which also makes it difficult to monitor the individual capacitors in the capacitor bank. This article proposed a digital twin system for dc-link capacitor banks with PCB integrated Rogowski coils as sensors. The system uses highly integrated Rogowski coils to obtain the operating currents of individual capacitors in order to realize parameter correction of the digital twin system and ensure that the digital twin system can accurately reflect the electrothermal behavior of the dc-link capacitor bank. In addition, the effect of operating temperature on capacitor parameters is also considered, and the capacitor parameters and the operating temperature monitored by the digital twin system simultaneously are used to standardize the parameters. The standardized parameters are used as indicators to realize the health status assessment of each capacitor in the capacitor bank, which further provide an important basis for operation and maintenance.

24 May 2022 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
YLYi Liu
Yi Liu
JBJu Bai
Ju Bai
MHmeng huang
meng huang
XZXiaoming Zha
Xiaoming Zha
State-of-the-art capacitor online monitoring methods are designed for the whole dc bank. The capacitance or equivalent series resistance of the dc bank, as an aging indicator, is obtained by the sensors installed at the dc terminal, or derived from the state equation of the system. The difference of capacitor parameters from manufacturing and the arrangement of the dc bank will result in uneven thermal stress for the capacitors. Due to the restriction of the low stray inductance specification and high power density requirement, the traditional online monitoring circuits are hard to be designed for the single capacitor in the dc bank. In this article, a Rogowski coil based online monitoring circuit has been designed for the single capacitor in the dc bank. A new aging criterion has been established for aluminum electrolytic capacitors based on the accelerated aging test. To achieve a compact integration design, a six-layer printed-circuit-board-type Rogowski coil is designed under an optimized frequency. A 2-kW single-phase inverter is built to verify the theoretical analysis and practical performance of the monitoring circuit.

26 September 2019 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
YLYi Liu
Yi Liu
Huai WangHuai Wang
Huai Wang
MHmeng huang
meng huang
XZXiaoming Zha
Xiaoming Zha
GZGuo-Rong Zhu
Guo-Rong Zhu
This letter proposes a simple yet practical power loss model of DC-link capacitors used in single-phase inverters. The low-frequency and high-frequency capacitor ripple current components make the existing power loss models either over-simplified by ignoring the high-frequency effects or over-complicated with detailed analytical solutions. The proposed simplified model can achieve negligible errors with respect to the detailed model without the need of double Fast Fourier Transform (FFT). Different modulations and topologies are analyzed to show the applicability of the proposed method. A 2-kW single-phase inverter case study is presented to demonstrate the accuracy and ease of use of the proposed model.

15 February 2023 in IEEE Journal of Emerging and Selected Topics in Industrial Electronics
Verified
Journal Article
Closed access
ZHZewei Hao
Zewei Hao
JGJinwu Gong
Jinwu Gong
YLYi Liu
Yi Liu
SPShangzhi Pan
Shangzhi Pan
XZXiaoming Zha
Xiaoming Zha
Current harmonic is an important factor in power converters' DC-link design. Its accurate derivation is conducive to estimating the reliability of DC-link capacitors. In active power filter (APF), due to its wide output bandwidth, the DC link suffers current harmonics on a broader spectrum, and the coupling effects among compensated harmonics make the derivation in this application more complex. However, the traditional methods in voltage source inverters (VSIs) usually assume the output current to be a simple sinusoid, or only calculate the root mean square (RMS) values. They cannot readily illustrate the coupling effect, nor discriminate between different modulation strategies. This paper presents a general method for APF to solve the DC-link current harmonics under any operation condition. Using Double-Fourier theory, a new variable called ‘harmonic factor’ is defined to describe the coupling effect among compensated harmonics. Then the DC-link current spectrum is quantitatively derived with the low-frequency compensated harmonics and the switching-frequency ripple currents. Finally, the simulation and experiment of a 2-level 100-A APF verify the theoretical analysis.

9 February 2022 in IEEE Journal on Emerging and Selected Topics in Circuits and Systems
Verified
Journal Article
Closed access
YLYi Liu
Yi Liu
XZXuejun Zhang
Xuejun Zhang
MHmeng huang
meng huang
XZXiaoming Zha
Xiaoming Zha
The power density and reliability of the inverter can be improved with reduced DC-link capacitance by swing bus operation, etc. With insufficient DC-link capacitance, a double line frequency voltage ripple will be superimposed on the DC link, but how this voltage ripple affects the power loss of the IGBT in the inverter system has been seldom discussed. This paper analyzes the influence of voltage fluctuations on the power loss of IGBT and establishes the characteristic database of IGBTs under different operating voltages and currents using a dynamic test chamber. A switching profile-based power loss model has been proposed to evaluate the power loss of IGBT in the single-phase inverter under different DC link voltage ripples. All the theoretical analysis has been verified by a 6-kW inverter platform under swing bus operation (SBO).

15 May 2023 in IEEE Transactions on Circuits and Systems II: Express Briefs
Verified
Journal Article
Closed access
PZpeijun zhong
peijun zhong
JSJianjun Sun
Jianjun Sun
PYPan Yu
Pan Yu
YLYi Liu
Yi Liu
XZXiaoming Zha
Xiaoming Zha
Impedance measurement unit (IMU) with injection of broadband perturbations is widely used to obtain grid and converter impedance. The accuracy of measured impedance and the power quality of the measured system rely on the amplitude control of the injected perturbations. However, the accuracy of output perturbation of IMU is lack of attention especially around the fundamental frequency of the measured system. In this brief, a three-phase DC-AC type IMU is introduced and the mechanism and solution of inaccurate perturbation output of the IMU is study. First, the DC-AC type IMU with PR current controllers, DC voltage controller and phase locked loop (PLL) is introduced. Next, the mechanism of inaccurate perturbation output is analysis, which is caused by the introduction of DC voltage ripple. Then, improved DC voltage control solutions with notch filter or delay filter are proposed to achieve the accurate control of single-frequency and multi-frequency perturbation current respectively. Finally, control hardware-in-the-loop experiment results are given to demonstrate and verify the effectiveness and feasibility of the proposed method.