To enhance the moisture damage performance of hot mix asphalt (HMA), treating the aggregate surface with a suitable additive was a more convenient approach. In this research, two types of aggregate modifiers were used to study the effect of moisture damage on HMA. Three different aggregate sources were selected based on their abundance of use in HMA. To study the impact of these aggregate modifiers on moisture susceptibility of HMA, the indirect tensile strength test and indirect tensile modulus test were used as the performance tests. Moisture conditioning of specimens was carried out to simulate the effect of moisture on HMA. The prepared samples’ tensile strength ratio (TSR) and stiffness modulus (Sm) results indicated a decrease in the strength of the HMA after moisture conditioning. After treating the aggregate surface with additives, an improvement was seen in dry and wet strength and stiffness. Moreover, an increasing trend was observed for both additives. The correlation between TSR and strength loss reveals a strong correlation (R2 = 0.7219). Also, the two additives indicate increased wettability of asphalt binder over aggregate, thus improving the adhesion between aggregate and asphalt binder.
23 May 2023 in Journal of Water and Climate Change
Global indicators have warned of freshwater scarcity in Asia. However, the utilization of freshwater resources has skyrocketed for commercial and industrial purposes without any strategy for recycling and reuse. The power plant's wastewater/reject mainly consisted of cooling tower blowdown water and reverse osmosis (RO) plant reject water. Due to the high turbid nature of reject water, pretreatment was carried out to achieve SDI15 <3 by employing multimedia filters (MMF), activated carbon filters (ACF) and ultrafiltration (UF). Operational parameters of RO membranes were optimized (11.5 bar, 29 °C) to achieve maximum water recovery along with higher rejection rates of critical scale forming species such as 81% total dissolved solids (TDS), 73% calcium hardness and 72% silica (Si). After accounting for backwash water and other concentrate rejections, the membrane treatment plant has achieved an appreciable recovery rate of more than 44%. The RO membrane-treated water was then incorporated in the cooling tower and a 16% reduction in freshwater makeup was achieved. Reduction of microbial growth rate as well as corrosion and scaling in the cooling tower was observed due to the reuse of treated water. This is to confirm here that brackish water RO membranes can act as a strong contender for reject water reclamation and effective utilization.