Objectives: 1) To quantify the audiometric differences between the preoperative tests with the Bone-Anchored Hearing Aid (BAHA) attached to the headband or the testband and the final postoperative result with the BAHA positioned at the implanted abutment. 2) To compare the results obtained with the headband and the testband. 3) To quantify the magnitude of the damping through the skin for the BAHA placed at the testband (important for comparison with the implantable hearing aids). Study Design: Prospective. Setting: Tertiary otological referral centre. Patients: Ten adult (≥14 yr old) BAHA patients (6 male and 4 female subjects) with bilateral air-bone gaps of minimum 40-dB hearing loss and with more than 6 months of BAHA experience with the BAHA "Compact." Methods: Audiometric free-field thresholds and speech audiometry scores (Consonant-Vowel-Consonant lists, phonemic score) have been evaluated for 3 conditions: BAHA attached to the implanted "Snap" abutment, to the headband, or to the testband. Results: For frequencies 1 to 4 kHz, significant differences in the range of 5 to 20 dB were found between the BAHA coupled with the Snap abutment and the preoperative testing conditions with the BAHA positioned at the headband or the testband. These differences were also reflected in the speech audiometry with a difference in speech reception threshold of approximately 4 to 7 dB. Conclusion: 1) Significant differences in the audiometric thresholds and the speech understanding scores were found between the preoperative test conditions and the final postoperative result. 2) Audiometric results obtained with the headband and the testband are comparable; therefore, the more comfortable headband is also suitable for the preoperative audiologic evaluation. 3) The magnitude of the skin damping must be accounted for when referring to the audiometric results obtained with the BAHA attached to the testband or headband.
Individuals with single-sided deafness (SSD) have no access to binaural hearing, which limits their ability to localize sounds and understand speech in noisy environments. In addition, children with prelingual SSD are at risk for neurocognitive and academic difficulties. Early cochlear implantation may lead to improved hearing outcomes by restoring bilateral hearing. However, its longitudinal impact on the development of children with SSD remains unclear. In the current study, a group of young children with prelingual SSD received a cochlear implant at an early age. From the age of four, the children’s spatial hearing skills could be assessed using a spatial speech perception in noise test and a sound localization test. The results are compared to those of two control groups: children with SSD without a cochlear implant and children with bilateral normal hearing. Overall, the implanted group exhibited improved speech perception in noise abilities and better sound localization skills, compared to their non-implanted peers. On average, the children wore their device approximately nine hours a day. Given the large contribution of maturation to the development of spatial hearing skills, further follow-up is important to understand the long-term benefit of a cochlear implant for children with prelingual SSD.
The acoustic voice quality index (AVQI) is a multiparametric tool based on six acoustic measurements to quantify overall voice quality in an objective manner, with the smoothed version of the cepstral peak prominence (CPPS) as its main contributor. In the last decade, many studies demonstrated its robust diagnostic accuracy and high sensitivity to voice changes across voice therapy in different languages. The aim of the present study was to provide information regarding AVQI’s and CPPS’s performance in normophonic non-treatment-seeking subjects, since these data are still scarce; concatenated voice samples, consisting of sustained vowel phonation and continuous speech, from 123 subjects (72 females, 51 males; between 20 and 60 years old) without vocally relevant complaints were evaluated by three raters and run in AVQI v.02.06. According to this auditory-perceptual evaluation, two cohorts were set up (normophonia versus slight perceived dysphonia). First, gender effects were investigated. Secondly, between-cohort differences in AVQI and CPPS were investigated. Thirdly, with the number of judges giving G = 1 to partition three sub-levels of slight hoarseness as an independent factor, differences in AVQI and CPPS across these sub-levels were investigated; for AVQI, no significant gender effect was found, whereas, for CPPS, significant trends were observed. For both AVQI and CPPS, no significant differences were found between normophonic and slightly dysphonic subjects. For AVQI, however, this difference did approach significance; these findings emphasize the need for a normative study with a greater sample size and subsequently greater statistical power to detect possible significant effects and differences.
Background Fitting cochlear implants in babies and noncooperative patients is cumbersome and time consuming. Therefore, objective parameters have been sought in order to predict the subjective threshold (T) and maximum comfort (C) levels. Measurements of the electrically evoked compound action potentials (ECAPs) have been widely used for this purpose, yet the correlation between these objective measures and the subjective T/C levels is weak to moderate. Purpose This article aims (1) to evaluate correlations between the subjective parameters of the fitting maps such as thresholds (T level) and maximum comfort levels (C level), the impedance of the electrode contacts, and the ECAP thresholds, and (2) to compare the value of the electrode impedances and the ECAP measures for prediction of the T/C levels. Research
Design Case review study in a quaternary otologic referral center. Study Sample Ninety-eight consecutive CI patients were enrolled. The average age of the patients was 49 years. All patients were users of the Nucleus 24RECA (Freedom, Contour Advance-of-Stylet electrode) cochlear implant. Data Collection and Analysis Data on impedance of the electrode contacts and the behavioral T/C levels at the first fitting session (2‐5 weeks after surgery) and at the 5th fitting session (4‐6 months after surgery) have been retrospectively collected in 98 consecutive CI patients. Additionally, the intraoperative impedance values and the ECAP thresholds (tNRT) have been recorded. Results Impedances of electrode contacts show significant strong negative correlations with the stabilized T/C levels at 4 to 6 months after implantation and are an important predictor for the behavioral T/C levels. They can explain R2 = 28 to 41% of the variability of the behavioral T/C levels. In multiple regression analysis electrode contact impedances can explain twice as much of the variability of the stabilized T/C levels than the tNRT values. The electrode impedances together with the tNRT values are able to explain R2 = 37 to 40% of the global variability of the T/C levels while the tNRT thresholds solely are able to explain only R2 = 5 to 14% of the T/C levels variability. Conclusion Impedances of electrode contacts correlate strongly with the stabilized behavioral T/C levels and may be used as an objective measure for fitting of cochlear implants.
16 December 2019 in The Journal of International Advanced Otology
OBJECTIVES: This study aimed to investigate the effect of canal wall up with bony obliteration tympanoplasty (CWU-BOT) on the health-related quality of life (HRQOL) in patients with chronic otitis media with cholesteatoma by using the chronic otitis media questionnaire 12 (COMQ-12). MATERIALS and METHODS: This study is a retrospective analysis of the COMQ-12 of 26 patients who completed the COMQ-12 before and after a CWU-BOT with eradication of cholesteatoma followed by obliteration of the mastoid and paratympanic space with bone chips and bone pâté and reconstruction of the tympanic membrane and ossicular chain. RESULTS: All patients were operated upon in our institute between 2014 and 2017. The median score of the 12 questions was preoperatively and postoperatively calculated, and then compared. A large effect was observed in the total score and the questions about running ear, discharge, and visits to the general practitioner. A medium positive size effect was observed in the questions about hearing in noisy surroundings, discomfort, dizziness, tinnitus, medication use, and the mental aspect of the patient. In the questions about the hearing at home and quality of life and impact on work, we noted a small positive size effect. In 50% of patients, the HRQOL became normal; the remaining 50% improved to a level very close to normal. CONCLUSION: Canal wall up with bony obliteration tympanoplasty (CWU-BOT) showed a clear decrease in the severity of the symptoms, life and work impact, and health care after surgery. Cite this article as: Baetens W, van Dinther J, Vanspauwen R, Maryn Y, Zarowski A, Offeciers E. Health Related Quality of Life after the Bony Obliteration Tympanoplasty for COM with Cholesteatoma using the COMQ12 - A Disease Specific PROM. J Int Adv Otol 2019; 15(3): 396-9.