Angel Ramo de Miguel

Dr. Angel Ramo de Miguel


Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 March 2022 in Audiology and Neurotology
Verified
Journal Article
Open access
PDF file
Ulrich HoppeUlrich Hoppe
Ulrich Hoppe
GBGoetz Brademann
Goetz Brademann
TSTimo Stöver
Timo Stöver
AMAngel Ramo de Miguel
Angel Ramo de Miguel
RCRobert Samuel Charles Cowan
Robert Samuel Charles Cowan
AMAngel Ramos Macías
Angel Ramos Macías
Introduction: Transimpedance measurements from cochlear implant electrodes have the potential to identify anomalous electrode array placement, such as tip fold-over (TFO) or fold-back, basal electrode kinking, or buckling. Analysing transimpedance may thus replace intraoperative or post-operative radiological imaging to detect any potential misplacements. A transimpedance algorithm was previously developed to detect deviations from a normal electrode position with the aim of intraoperatively detecting TFO. The algorithm had been calibrated on 35 forced, tip folded electrode arrays in six temporal bones to determine the threshold criterion required to achieve a sensitivity of 100%. Our primary objective here was to estimate the specificity of this TFO algorithm in patients, in a prospective study, for a series of electrode arrays shown to be normally inserted by post-operative imaging. Methods: Intracochlear voltages were intraoperatively recorded for 157 ears, using Cochlear’s Custom Sound™ EP 5 electrophysiological software (Cochlear Ltd., Sydney, NSW, Australia), for both Nucleus® CI512 and CI532 electrode arrays. The algorithm analysed the recorded 22 × 22 transimpedance matrix (TIM) and results were displayed as a heatmap intraoperatively, only visible to the technician in the operating theatre. After all clinical data were collected, the algorithm was evaluated on the bench. The algorithm measures the transimpedance gradients and corresponding phase angles (θ) throughout the TIM and calculates the gradient phase range. If this was greater than the predetermined threshold, the algorithm classified the electrode array insertion as having a TFO. Results: Five ears had no intraoperative TIM and four anomalous matrices were identified from heatmaps and removed from the specificity analysis. Using the 148 remaining data sets (n = 103 CI532 and n = 45 CI512), the algorithm had an average specificity of 98.6% (95.80%–99.75%). Conclusion: The algorithm was found to be an effective screening tool for the identification of TFOs. Its specificity was within acceptable levels and resulted in a positive predictive value of 76%, with an estimated incidence of fold-over of 4% in perimodiolar arrays. This would mean 3 out of 4 cases flagged as a fold-over would be correctly identified by the algorithm, with the other being a false positive. The measurements were applied easily in theatre allowing it to be used as a routine clinical tool for confirming correct electrode placement.

10 January 2020 in Audiology and Neurotology
Verified
Journal Article
Open access
AMAngel Ramo de Miguel
Angel Ramo de Miguel
AZAndrzej Zarowski
Andrzej Zarowski
MSMorgana Sluydts
Morgana Sluydts
AMAngel Ramos Macias
Angel Ramos Macias
FWFloris L. Wuyts
Floris L. Wuyts
Background: The peripheral vestibular end organ is considered to consist of semi-circular canals (SCC) for detection of angular accelerations and the otoliths for detection of linear accelerations. However, otoliths being phylogenetically the oldest part of the vestibular sensory organs are involved in detection of all motions. Summary: This study elaborates on this property of the otolith organ, as this concept can be of importance for the currently designed vestibular implant devices. Key Message: The analysis of the evolution of the inner ear and examination of clinical examples shows the robustness of the otolith system and inhibition capacity of the SCC. The otolith system must be considered superior to the SCC system as illustrated by evolution, clinical evidence, and physical principles.

2 April 2018 in European Archives of Oto-Rhino-Laryngology
Verified
Journal Article
Closed access
PDF file
AMAngel Ramo de Miguel
Angel Ramo de Miguel
AAAndrea A. Argudo
Andrea A. Argudo
SBSilvia A. Borkoski Barreiro
Silvia A. Borkoski Barreiro
JGJuan Carlos Falcón González
Juan Carlos Falcón González
AMAngel Ramos Macías
Angel Ramos Macías

17 October 2014 in European Archives of Oto-Rhino-Laryngology
Verified
Journal Article
Closed access
PDF file
AMAngel Ramo de Miguel
Angel Ramo de Miguel
TPTeresa Perez-Zaballos
Teresa Perez-Zaballos
DPDaniel Perez
Daniel Perez
JFJuan Carlos Falconb
Juan Carlos Falconb
ARAngel Ramosb
Angel Ramosb

31 August 2021 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
AMAngel Ramo de Miguel
Angel Ramo de Miguel
JFJuan Carlos Falcón-González
Juan Carlos Falcón-González
Ramos Macias, AngelRamos Macias, Angel
Ramos Macias, Angel
Background: The proximity of the electrode to the modiolar wall may be of interest to investigate the effect of pitch discrimination. This research establishes the relation between these factors and whether perimodiolar positions may provide benefits regarding improved electrode discrimination. Methods: A prospective randomized study including 24 post-lingual deaf adults was performed. A psychoacoustic study was done by using a psychoacoustic research platform. Radiological study, and a cone-beam computed tomography was used to assess post cochlear implantation electrodes’ position. Trans-impedance matrix (TIM) analysis was performed after cochlear implant insertion in all cases, and pupillometry test was also performed. Results: 12 patients received a slim perimodiolar electrode array, and 12 patients received a straight electrode array. Although all the patients showed similar speech test results after 12 months follow-up, those implanted with a perimodiolar electrode obtained better scores in electrode discrimination test and pupillometry test, and showed more homogenous TIM patterns. Conclusions: The better positioning of the electrode array seams to provide a better hearing resolution and less listening effort trans-impedance matrix seems to be a useful tool to analyze positioning of the perimodiolar array.

1 June 2016 in European Annals of Otorhinolaryngology, Head and Neck Diseases
Verified
Journal Article
Closed access
ÁMÁ. Ramos Macías
Á. Ramos Macías
SBS.A. Borkoski-Barreiro
S.A. Borkoski-Barreiro
JGJ.C. Falcón González
J.C. Falcón González
AMAngel Ramo de Miguel
Angel Ramo de Miguel