Juan Carlos Falcón-González

Dr. Juan Carlos Falcón-González

orcid

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
31 August 2021 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
AMAngel Ramo de Miguel
Angel Ramo de Miguel
JFJuan Carlos Falcón-González
Juan Carlos Falcón-González
Ramos Macias, AngelRamos Macias, Angel
Ramos Macias, Angel
Background: The proximity of the electrode to the modiolar wall may be of interest to investigate the effect of pitch discrimination. This research establishes the relation between these factors and whether perimodiolar positions may provide benefits regarding improved electrode discrimination. Methods: A prospective randomized study including 24 post-lingual deaf adults was performed. A psychoacoustic study was done by using a psychoacoustic research platform. Radiological study, and a cone-beam computed tomography was used to assess post cochlear implantation electrodes’ position. Trans-impedance matrix (TIM) analysis was performed after cochlear implant insertion in all cases, and pupillometry test was also performed. Results: 12 patients received a slim perimodiolar electrode array, and 12 patients received a straight electrode array. Although all the patients showed similar speech test results after 12 months follow-up, those implanted with a perimodiolar electrode obtained better scores in electrode discrimination test and pupillometry test, and showed more homogenous TIM patterns. Conclusions: The better positioning of the electrode array seams to provide a better hearing resolution and less listening effort trans-impedance matrix seems to be a useful tool to analyze positioning of the perimodiolar array.

27 September 2022 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
IMISAURA RODRIGUEZ MONTESDEOCA
ISAURA RODRIGUEZ MONTESDEOCA
AMAngel Ramo de Miguel
Angel Ramo de Miguel
JFJuan Carlos Falcón-González
Juan Carlos Falcón-González
SBSilvia Andrea Borkoski Barreiro
Silvia Andrea Borkoski Barreiro
SBSusana Benítez-Robaina
Susana Benítez-Robaina
Ramos Macias, AngelRamos Macias, Angel
Ramos Macias, Angel
(1) Background. Patients with bilateral vestibular disease (BVD) experience oscillopsia with a detriment to visual acuity (VA). This VA is driven mainly by the VOR that has two components: rotational and translational. VA can be tested by using dynamic visual acuity (DVA) on a treadmill because both systems are activated. The aim of this study is to compare VA before and after chronic electrical stimulation of the otolith organ. (2) Materials and Method. Five patients suffering from bilateral vestibular dysfunction (BVD), previously implanted with a new vestibular implant prototype, were included in this study with the aim to check VA with and without vestibular implant use (W and W/O) in static, 2 km/h and 4 km/h walking situations. DVAtreadmill was measured on a treadmill with a dynamic illegible E (DIE) test in static and dynamic conditions (while walking on the treadmill at 2 and 4 km/h). The DVA score was registered in a logarithm of the minimum angle of resolution (LogMAR) for each speed. In addition, every patient completed the oscillopsia severity questionnaire (OSQ) and video head impulse test (vHIT) before and after activation of the vestibular implant. (3) Results. The analysis shows a significant difference in OSQ scores and DVA with an improvement in dynamic conditions. Organized corrective saccades during the use of a vestibular implant with no changes in gain were also detected in the video head impulse tests (vHIT). (4) Conclusion. The vestibular implant with otolithic stimulation offers changes in the response of DVA, which makes this paper one of the first to address the possible restoration of it. It is not possible to rule out other contributing factors (presence of covert saccades, somatosensory system, …). More work seems necessary to understand the neurophysiological basis of these findings, but this implant is added as a therapeutic alternative for the improvement of oscillopsia.

1 September 2014 in Acta Otorrinolaringológica Española
Verified
Journal Article
Closed access
JFJuan Carlos Falcón-González
Juan Carlos Falcón-González
SBSilvia Borkoski-Barreiro
Silvia Borkoski-Barreiro
JLJosé María Limiñana-Cañal
José María Limiñana-Cañal
ÁRÁngel Ramos-Macías
Ángel Ramos-Macías

Verified
Journal Article
Open access
PDF file
ÁMÁngel Ramos de Miguel
Ángel Ramos de Miguel
DSDiego Riol Sancho
Diego Riol Sancho
JFJuan Carlos Falcón-González
Juan Carlos Falcón-González
JPJoana Milagros Pavone
Joana Milagros Pavone
LHLeandro Rodríguez Herrera
Leandro Rodríguez Herrera
Ramos Macias, AngelRamos Macias, Angel
Ramos Macias, Angel
New cochlear implant (CI) electrode arrays provide softer insertion dynamics; however, due to their high flexibility, the possibilities of fold-overs or intraoperative displacements must be taken into account. The position of each individual electrode can only be determined by using high-resolution computed tomography or cone-beam CT. The trans-impedance matrix test (TIM) is an electrophysiological method based on electric field imaging that can provide images of electrode position and electrode folding. Objective: In this experimental research, we evaluated the result of TIM as a method of monitoring cochlear insertion for a precurved slim modiolar electrode array in fresh human temporal bones by analyzing the transimpedance matrix patterns and their correlation with electrode position using high-resolution computed tomography. Material and Methods: Sixteen slim modiolar electrode arrays were inserted into eight fresh Human Temporal Bones. Eight electrodes were inserted according to the correct methodology of insertion, and eight were intentionally folded over. After all insertions, a trans-impedance matrix analysis and a Cone Beam CT (CBCT) were performed in each temporal bone. Results: If we correlated the TIM patterns with the radiological electrode position, we observed that better electrode intracochlear positions indicated more “homogeneous” TIM patterns (intracochlear voltage dropped monotonically as the distance between stimulation and recording contact increased, both toward the apex and toward the base). A correlation where fold-over was detected in the TIM results was found in all eight temporal bone radiological findings. Conclusions: Trans-Impedance Matrix patterns were correlated with the radiological CI electrode position. When a tip fold-over appeared, a matrix with a secondary ridge in addition to the primary ridge was observed in all cases. TIM can be an effective method in the control of electrode positioning.

1 May 2025 in Otology & Neurotology
Verified
Journal Article
Open access
Ramos Macias, AngelRamos Macias, Angel
Ramos Macias, Angel
JFJuan Carlos Falcón-González
Juan Carlos Falcón-González
SBSilvia Andrea Borkoski Barreiro
Silvia Andrea Borkoski Barreiro
NBNADIA FALCÓN BENÍTEZ
NADIA FALCÓN BENÍTEZ
JTJoyce Tang
Joyce Tang
AMAngel Ramo de Miguel
Angel Ramo de Miguel
Objectives: The aim of this study is to show the long-term effects of cochlear implant as a treatment in both children and adults with acquired single-sided deafness. Study Design: Observational, descriptive, cross-sectional. Setting: Tertiary referral center. Patients: 21 children and 20 adults with SSD. Intervention(s): Unilateral CI. Methods: Speech detection thresholds and disyllabic words test (65 dB SPL) were performed in the modalities azimuth (S0), signal CI side (SCI), and signal on the normal hearing (SNH). The normal ear was masked with both white noise of +10 dB of the hearing threshold and plugging the same ear, whereas the speech testing was performed using the cochlear implant wireless system. Results: All results were obtained up to 48 months after the activation of the sound processor. All study subjects showed improvements in speech test results in all conditions tested. Word recognition in noise in children improved from 42.76% at 6 months after activation of the sound processor to 76.38% at 48 months in the S0 condition, from 50 to 78.10% in the SCI condition, and from 38.48 to 66.48% in the SNH modality. Regarding adults, word recognition in noise went from 45.40% at 6 months of activation of the sound processor to 73.40% at 48 months in the S0 condition, from 52.60 to 76.20% in the SCI condition, and from 43.60 to 64.80% in the SCI condition (p < 0.001). The average duration of use of the speech processor daily was 11 hours in children and 9.4 hours in adults. Conclusion: When comparing children's performance with adults', progressive improvement in speech discrimination compared with adults was observed.

1 November 2022 in The Journal of International Advanced Otology
Verified
Journal Article
Open access
SBSusana Benítez-Robaina
Susana Benítez-Robaina
ÁRÁngel Ramos-Macias
Ángel Ramos-Macias
SBSilvia Borkoski-Barreiro
Silvia Borkoski-Barreiro
JFJuan Carlos Falcón-González
Juan Carlos Falcón-González
PSPatricia Salvatierra
Patricia Salvatierra
AMAngel Ramo de Miguel
Angel Ramo de Miguel
BACKGROUND: The aim of this study was to assess the effect on speech perception and lack of hearing devices gain with surgical masks worn in hearing aid users. METHODS: This prospective cohort study enrolled consecutive patients between November 2020 and February 2021 in a tertiary care medical center from Spain. Fifty-five subjects have been included, 10 as control group, with normal hearing, and 45 patients with sensory-neural hearing loss and hearing aid users, ranging in age between 31 and 83 years old, and were recruited randomized in 4 months. Appropriate test was done previously to check adequate functioning from devices and suitable adaptation. Control group had no hearing impairment neither otologic disease. RESULTS: Disyllabic test in quiet get worse with face mask with a significant difference and stronger impact in noisy background. Age made no difference. Adding lipreading speech perception improved by 95.1 % for younger subjects (50 years of age). In the control sample, there was no differences in any condition. CONCLUSION: Despite advantages of wearing mask in preventing coronavirus disease 2019 spread, we must consider that they have also drawbacks for some groups like hearing aid users. In this research, we have not observed high frequencies perception decrease with surgical masks worn, but there was reduction in speech perception, most notably in hearing aids wearers in noisy environment. Cite this article as: Benítez-Robaina S, Ramos-Macias Á, Borkoski-Barreiro S, Falcón-González JC, Salvatierra P, Ramos-De Miguel A. COVID-19 era: Hearing handicaps behind face mask use in hearing aid users. J Int Adv Otol. 2022;18(6):465-470.