Dissecting a human cadaver is an irreplaceable practice in general training of medical students. Cadavers in anatomy laboratories are usually preserved in formalin, an embalming fluid whose basic component is formaldehyde (FA). The aim of this study is to assess the cancer risk of employees and students that are exposed to FA based on the results of three monitoring campaigns, as well as to suggest permanent solutions to the problem of FA exposure based on the results obtained. Three sampling campaigns of formaldehyde concentration in indoor environments were conducted at five different locations at the Anatomy Department of the Faculty of Medicine with the purpose of assessing permanent employees’ and medical faculty first year students’ exposure to FA. Indoor air was continuously sampled during 8 h of laboratory work and analyzed in accordance with the NIOSH Method 3500. Exceeding of the 8 h time-weighted average (8 h TWA) values recommended by Occupational Safety and Health Administration (OSHA) of 0.75 ppm was recorded in 37% of the samples during the three-month monitoring campaign. Cancer risk assessment levels for permanent employees were in the range from 6.43 × 10−3 to 8.77 × 10−4, while the cancer risk assessment levels for students ranged from 8.94 × 10−7 to 1.83 × 10−6. The results of the research show that cancer risk assessment for employees is several thousand times higher than the limit recommended by the EPA (10−6) and point to the importance of reducing exposure to formaldehyde through the reconstruction of the existing ventilation system, continual monitoring, the use of formaldehyde-free products, and plastination of anatomical specimens.
Pyrolysis is an optimal thermochemical process for obtaining valuable products (char, oil, and gas) from waste tires. The preliminary research was done on the three groups of samples acquired by cutting the same waste tire of a passenger vehicle into cylindrical granules with a base diameter of 3, 7, and 11 mm. Each batch weighed 10 g. The heating rate was 14 °C/min, and the final pyrolysis temperature was 750 °C, with 90 s residence time. After the pyrolysis product yields were determined for all of the three sample groups, further research was performed only on 3 mm granules, with the same heating rate, but with altered final pyrolytic temperatures (400, 450, 500, 550, 600, 650, 700, and 750 °C). The results of this study show that thermochemical decomposition of the waste tire sample takes place in the temperature range of 200–500 °C, with three distinct phases of degradation. The highest yield of the pyrolytic oil was achieved at a temperature of 500 °C, but further heating of volatile matters reduced the oil yield, and simultaneously increased the yield of gas, due to the existence of secondary cracking reactions. The analysis of pyrolytic oil and char showed that these products can be used as fuel.
The experimental investigation presented in this research was performed in order to examine the possibility of the removal of SO2 from flue gases by cleaning with a solution of lime suspension and formic acid (Ca(OH)2 and HCOOH). Research was conducted in a laboratory plant (rotary kiln) of 44 kW. The mass of the lime suspension (LS) was 400 g. The mass of the LS was homogenized (mixed) in a sample cup with 2 g (0.5%), 4 g (1%) and 8 g (2%) of 60% formic acid. The solution was placed in a gas washing bottle, where a partial flow of flue gas generated by the combustion of diesel fuel was injected. Simultaneously with the diesel fuel combustion, SO2 from a bottle was injected in a rotary kiln. The average mass concentration of SO2 in the flue gas at the entry point of the gas washing bottle was around 2900 ppm. The results indicated that the absorption of SO2 by the cleaning of flue gas with LS was 96.83%. Adding formic acid to the LS in mass ratios of 0.5% (2 g), 1% (4 g) and 2% (8 g) resulted in absorptions of 99.25%, 98.77% and 98%, respectively. The absorption of flue gases in the gas washing bottle with LS, with the addition of formic acid in the mentioned ratios, showed a reduction in sulfates and pH value, and a rise in sulfides and calcium, respectively.
2 August 2022 in Polish Journal of Environmental Studies
This paper gives an overview of the current situation in the field of energy and municipal solid waste management (MSWM) in Serbia with the emphasis on identification of opportunities and challenges related to obtaining energy from municipal solid waste (MSW) on a specific example of the future waste management center in Belgrade (Serbia). This waste management center will be equipped with two plants for energy production, from waste and from landfill gas. These plants will annually produce about 216 GWh of electricity and about 174 GWh of heat. The importance of such a project is manifold because it solves the long-standing problem of waste management in Belgrade based on landfilling at the non-sanitary landfill Vinca, which is a great burden on the environment with potential risk to human health, while introducing a new dimension in energy production in Serbia.
Considering that the determination of fire hazard zones in warehouses is not sufficiently researched and studied, this paper aims to present a new methodological approach concerning the mentioned issue. Based on the COPRAS multi-criteria decision-making method, a new method was developed for the precise determination of potential zones where there is a risk of fire. The advantage of the described method is that it allows the quick and easy determination of all-orientation fire risk zones. The method requires fewer hardware resources compared to the existing ones and enables the display of the warehouse space in the form of a 3D model with calculated fire hazard zones. The mentioned procedure represents the first step when planning the layout and arrangement in the warehouse itself. The effectiveness of the proposed method was confirmed through a suitable numerical example.
The establishment of the monitoring, reporting and verification (MRV) system for greenhouse gas emissions in the Republic of Serbia represents an important step towards the future implementation of an emissions trading framework and the harmonization of national climate policy with the European Union acquis. Following the adoption of the national monitoring and reporting regulation, operators were required to apply for greenhouse gas emission permits and submit monitoring plans with supporting documentation. This paper presents the implementation process from the adoption of the regulatory framework and preparation of operators to the completion of the first reporting year. Special attention is given to practical challenges identified during the preparation and implementation of monitoring plans, including the identification of emission sources and source streams, selection of activity data sources, application of monitoring tiers, development of internal procedures and assessment of data uncertainty. Experiences from the first reporting year are illustrated through the example of a category B district heating operator with annual emissions of approximately 95.000 t CO 2. The results indicate that the first reporting cycle provided valuable experience for operators, verifiers and competent authorities, while highlighting the need for further capacity building and methodological clarification.