Pyrolysis is an optimal thermochemical process for obtaining valuable products (char, oil, and gas) from waste tires. The preliminary research was done on the three groups of samples acquired by cutting the same waste tire of a passenger vehicle into cylindrical granules with a base diameter of 3, 7, and 11 mm. Each batch weighed 10 g. The heating rate was 14 °C/min, and the final pyrolysis temperature was 750 °C, with 90 s residence time. After the pyrolysis product yields were determined for all of the three sample groups, further research was performed only on 3 mm granules, with the same heating rate, but with altered final pyrolytic temperatures (400, 450, 500, 550, 600, 650, 700, and 750 °C). The results of this study show that thermochemical decomposition of the waste tire sample takes place in the temperature range of 200–500 °C, with three distinct phases of degradation. The highest yield of the pyrolytic oil was achieved at a temperature of 500 °C, but further heating of volatile matters reduced the oil yield, and simultaneously increased the yield of gas, due to the existence of secondary cracking reactions. The analysis of pyrolytic oil and char showed that these products can be used as fuel.
A building energy performance gap can be illustrated as the difference between the theoretical (methodologically defined) and the actual energy consumption. In EU countries, Energy Performance Certificates are issued when buildings are constructed, sold, or leased. This information is the first step in order to evaluate the energy performance of the building stock. In Serbia, when issuing an energy certificate, the adopted national methodology recognizes only energy consumption for heating. The main purpose of this paper is to evaluate the energy gap and estimate the relevance of an Energy Performance Certificate to meet the national energy efficiency or carbon target. An Energy Performance Certificate determines the theoretical residential and commercial building energy efficiency or its “design intent”. This research stresses the necessity of measuring and achieving reductions in actual energy consumption through system regulation and consumers’ self-awareness in buildings. The research compares the performance of the building stock (135) that is connected to the District Heating System (DHS), with its own integrated heat meter, to Individual Gas Boiler (IGB) systems (18), in the city of Novi Sad, Serbia, built after 2014. For the purpose of comparing energy consumption, 16 buildings were selected that are very similar in terms of design, operation, and location. The data used are derived from metered consumption data, official evidence of city service companies, and Energy Performance Certificates of the considered buildings. We have determined that IGB systems have a much wider specific annual performance gap (11.19–101 kWh/m2a) than the buildings in the DHS (3.16–18.58 kWh/m2a).
Considering that the determination of fire hazard zones in warehouses is not sufficiently researched and studied, this paper aims to present a new methodological approach concerning the mentioned issue. Based on the COPRAS multi-criteria decision-making method, a new method was developed for the precise determination of potential zones where there is a risk of fire. The advantage of the described method is that it allows the quick and easy determination of all-orientation fire risk zones. The method requires fewer hardware resources compared to the existing ones and enables the display of the warehouse space in the form of a 3D model with calculated fire hazard zones. The mentioned procedure represents the first step when planning the layout and arrangement in the warehouse itself. The effectiveness of the proposed method was confirmed through a suitable numerical example.
A Kohonen Self-organizing maps are an artificial neural network that is trained using unsupervised learning to produce a two-dimensional map. Self-organizing maps were once used for creating World poverty map on the eve of breakdown of Yugoslavia. This map compared 39 indicators for quality of life in 126 countries. Yugoslavia mapped close to the most developed countries. This paper uses the same methodology to present level of energy sustainability of Serbia by its comparison with selected countries, from Nordic ones, through World powers, in total 26 countries. From International Energy Agencys Atlas of energy 19 indicators were chosen, some adjusted for creating the Self-organizing map, where lower values are defined as energy sustainable ones. Mapping the countries itself shows the closeness to energy sustain ability champions. Also maps offer possibility to identify clusters of countries with similar energy policies. Seven clusters were identified based on four lights energy sustainability semaphore. Cluster contains at least three matches in selected parameters. Position in a low energy sustainable region of the map is an impetus to adjust energy policy.