We report on a miniature all-fiber dual parameter sensor capable of simultaneous measurement of the refractive index (RI) and temperature of fluids and gases. The high-sensitivity sensing element is comprised of two Fabry–Perot (FP) micro-resonators fabricated in a single-mode fiber and has a total length of . The RI sensing cavity is formed by diamond blade dicing, whereas a thinner silicon inlay glued into it serves as a temperature sensor. The sensor’s performance was tested on sucrose solutions over a range of temperatures. For the evaluation of the backreflected FP spectra, phase tracking of the characteristic Fourier transform components was used. Good accuracy (0.01°C) and linearity of temperature measurement with Si inlay with sensitivity 0.097 rad/°C (85.2 pm/°C) were found, whereas the open cavity allowed for reliable temperature-compensated measurements of RI steps with 290 rad/RIU (1130 nm/RIU) sensitivity.
We report on a fiber-integrated refractive index sensor based on a Fabry–Perot micro-resonator fabricated using simple diamond blade dicing of a single-mode step-index fiber. The performance of the device has been tested for the refractive index measurements of sucrose solutions as well as in air. The device shows a sensitivity of 1160 nm/RIU (refractive index unit) at a wavelength of 1.55 μm and a temperature cross-sensitivity of less than . Based on evaluation of the broadband reflection spectra, refractive index steps of of the solutions were accurately measured. The conducted coating of the resonator sidewalls with layers of a high-index material with real-time reflection spectrum monitoring could help to significantly improve the sensor performance.
In this work, we present a fiber sensor designed to measure simultaneously spatial inhomogeneities of the refractive index and temperature in liquid media, for example, induced by biochemical reactions. The sensor’s constituent elements are Fabry–Perot microresonators fabricated in standard single-mode optical fibers by diamond blade dicing. To allow simultaneous measurements of different refractive indices, the sensor comprises two open cavities approximately 2 mm apart. With a small Si inlay inserted into one of the resonators used for temperature measurements, the sensor allows for immediate compensation of crosstalk between temperature- and composition-induced fluids’ refractive index changes. The measurements were evaluated by phase tracking of the characteristic Fourier transform components of the sensor’s backreflected spectra. The temperature sensitivity of the Si inlay is 0.063 rad/°C (79 pm/°C), and an accuracy of 0.01°C is obtained. Meanwhile, the two refractive index sensing (open) cavities show a sensitivity of 1168 and 1153 nm/RIU for temperature-compensated measurements. Finally, the sensor performance to measure spatial distributions is demonstrated by measuring the diffusion behavior of sucrose in water, which allows precise monitoring of hydration effects and breaking of bonds at elevated temperatures.
Single-cycle, high-power, high-repetition-rate THz pulse sources are becoming the cornerstone of several scientific and industrial applications. A promising and versatile method for high-power THz generation is optical rectification in nonlinear crystals pumped by powerful near-infrared ultrafast laser systems. In this context, ytterbium-based laser sources are particularly advantageous in terms of power scalability and technology establishment. However, as the repetition rate increases toward hundreds of MHz, the conversion efficiency typically decreases, as most laser systems do not reach sufficiently high average powers to correspondingly enhance the peak power to drive the nonlinear conversion process efficiently. An alternative approach to achieving a sufficiently high average power at a high repetition rate is based on passive enhancement cavities, which boost the pulse energy of standard watt-level ytterbium lasers by orders of magnitude. We present the first demonstration of optical rectification in a passive enhancement cavity at multi-kW levels, achieved by a 240-fold power enhancement. By irradiating a 50-μm thin lithium niobate plate with 1.9-kW average power inside the enhancement cavity, we generate milliwatt-level THz pulses with 2-THz bandwidth and 93-MHz repetition rate, mostly limited by the driving pulse duration. To the best of our knowledge, this represents the highest driving average power used for optical rectification. This methodology represents a promising new step toward high-repetition-rate and high average power single-cycle THz sources using widely available multi-watt level Yb lasers.
We report on the study of high-temperature zirconium in-diffusion in congruent z-cut lithium tantalate crystals. Zirconium (Zr) concentration profiles in samples prepared at different diffusion times and temperatures were investigated using secondary neutral mass spectrometry. From the diffusion profiles specific diffusion constant and activation energy were obtained. Zr-induced near-surface refractive index changes were extracted by means of prism-coupler measurements, and their correlation with Zr concentration was studied. Subsequently, low-loss optical ridge waveguides were diced and their resistance to photorefractive optical damage in the blue (405 nm) and green (532 nm) spectral ranges was measured, demonstrating damage thresholds in the multi-MW/cm2 range.