Peter Mardle

Peter Mardle

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 July 2023 in ACS Energy Letters
Verified
Journal Article
Closed access
PMPeter Mardle
Peter Mardle
BCBinyu Chen
Binyu Chen
SHSteven Holdcroft
Steven Holdcroft

15 November 2021 in The Journal of Physical Chemistry C
Verified
Journal Article
Closed access
PMPeter Mardle
Peter Mardle
SCSimon Cassegrain
Simon Cassegrain
FHFaezeh Habibzadeh
Faezeh Habibzadeh
Zhiqing ShiZhiqing Shi
Zhiqing Shi
SHSteven Holdcroft
Steven Holdcroft

8 June 2022 in Sustainable Energy & Fuels
Verified
Journal Article
Closed access
PDF file
QWQiliang Wei
Qiliang Wei
XCXinzhi Cao
Xinzhi Cao
PVPhilipp Veh
Philipp Veh
AKAnastasiia Konovalova
Anastasiia Konovalova
PMPeter Mardle
Peter Mardle
SHSteven Holdcroft
Steven Holdcroft
We report the anion exchange membrane fuel cell (AEMFC) performance using commercial, polyimidazolium-based, Aemion+® as both the ionomer and membrane. Aemion+® affords reduced dimensional swelling yet higher water permeance compared to previously reported polybenzimidazolium-based Aemion® membranes and ionomers. Non-reinforced Aemion+® is shown to enhance the properties of Aemion® membranes, and Aemion+® reinforced with a fluorine-free polyolefin substrate is shown to enhance the properties considered important to fuel cell operation with respect to non-reinforced analogues. The highest AEMFC power density of 1.4 W cm−2 at 70 °C, 250 kPabs H2/O2 was obtained by using a direct membrane deposition (DMD) approach, where an ultrathin 5 μm membrane increased the voltage stability through enhanced water permeation, allowing characterization under these conditions. However, the reinforcement was found to be pivotal in enabling stable AEMFC operation at 80 °C, where a 10 μm-thick reinforced Aemion+® provided 1.1 W cm−2 power at 80 °C, 300 kPaabs H2/O2. The degradation properties of this material under varied cell temperatures, current densities and RHs are finally examined.

13 June 2023 in ChemSusChem
Verified
Journal Article
Open access
PMPeter Mardle
Peter Mardle
AGApurva Gangrade
Apurva Gangrade
TSTorben Saatkamp
Torben Saatkamp
ZJZhengming Jiang
Zhengming Jiang
SCSimon Cassegrain
Simon Cassegrain
SHSteven Holdcroft
Steven Holdcroft
The dependence of performance and stability of a zero‐gap CO2 electrolyzer on the properties of the anion exchange membrane (AEM) is examined. This work firstly assesses the influence of the anolyte when using an Aemion membrane and then shows that when using 10 mM KHCO3, a CO2 electrolyzer using a next‐generation Aemion+ membrane can achieve lower cell voltages and longer lifetimes due to increased water permeation. The impact of lower permselectivity of Aemion+ on water transport is also discussed. Using Aemion+, a cell voltage of 3.17 V at 200 mA cm−2 is achieved at room temperature, with a faradaic efficiency of >90 %. Stable CO2 electrolysis at 100 mA cm−2 is demonstrated for 100 h, but with reduced lifetime at 300 mA cm−2. However, the lifetime of the cell at high current densities is shown to be increased by improving water transport characteristics of the AEM and reducing dimensional swelling, as well as by improving cathode design to reduce localized dehydration of the membrane.


26 January 2023 in Journal of the Electrochemical Society
Verified
Journal Article
Open access
PDF file
XWXin Wang
Xin Wang
PMPeter Mardle
Peter Mardle
MAMichael Adamski
Michael Adamski
BCBinyu Chen
Binyu Chen
SHSteven Holdcroft
Steven Holdcroft
Herein, fully hydrocarbon-based ionomer catalyst coated membranes (CCM)s based on sulfo-phenylated polyphenylene biphenyl (sPPB-H+) are evaluated in a proton exchange membrane water electrolyzer cell at 70 °C. In conjunction with catalyst layers incorporating Nafion® D520 ionomer, sPPB-H+ membranes require a lower applied potential than reference Nafion® NR112 recast membranes of equal thickness, e.g., 1.66 V vs 1.75 V at 1 A cm−2. Initially, sPPB-H+ membranes yield substantially lower gas crossover compared to the CCMs containing NR112 membrane, however, increasing gas crossover and a higher rates of voltage evolution is measured during a stability test at 1 A cm−2. A reinforced and commercialized membrane of similar chemistry (Pemion®) is also evaluated, demonstrating smaller changes to the initial gas crossover owing to higher mechanical stability. Employment of sPPB-H+ as the catalyst layer binder is also investigated, where the highest efficiency for all-sPPB-H+ CCMs is achieved when the anode and cathode ionomer content are 20 wt%, which from electrochemical impedance spectroscopy is predominately attributed to changes in the proton conductivity within the catalyst layer. Despite this advancement, high ionomer swelling and catalyst delamination led to shorter electrolyzer lifetimes for the all hydrocarbon and non fluorinated membrane electrode assembly, informing future ionomer development.